INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
7KLV ¿UHSODFH XVHV 6/ 6HULHV &KLPQH\
2" CLEARANCE TO COMBUSTIBLES AND BUILDING INSULATION FROM CHIMNEY REQUIRED.
NOTICE:
DO NOT discard this manual!
Model(s):
WOODBURNING FIREPLACE
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recomends HHT
Factory Trained or NFI certified professionals.
Installation Manual
Installation and Fireplace Setup
Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24
WARNING: If the information in these
LQVWUXFWLRQV LV QRW IROORZHG H[DFWO\ D ¿UH
or explosion may result causing property
damage, personal injury, or death.
• DO NOT VWRUH RU XVH JDVROLQH RU RWKHU ÀDP-
PDEOH YDSRUV DQG OLTXLGV LQ WKH YLFLQLW\ RI WKLV
or any other appliance.
• DO NOT RYHU¿UH 2YHU¿ULQJ ZLOO YRLG \RXU
warranty.
• Comply with all minimum clearances to com-
EXVWLEOHV DV VSHFL¿HG )DLOXUH WR FRPSO\ PD\
FDXVH KRXVH ¿UH
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
¿UHSODFH
• Alert children and adults to hazards of high temperatures.
+LJK WHPSHUDWXUHV PD\ LJQLWH FORWKLQJ RU RWKHU ÀDPPDEOH
materials.
‡ .HHS FORWKLQJ IXUQLWXUH GUDSHULHV DQG RWKHU ÀDPPDEOH
materials away.
WARNING
Fire Risk.
For use with solid wood fuel only.
2WKHU IXHOV PD\ RYHU¿UH DQG JHQHUDWH SRLVRQRXV
JDVHV LH FDUERQ PRQR[LGH 
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ashland ASH36 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Majestic Ashland ASH36

  • Page 1 Factory Trained or NFI certified professionals. WARNING Fire Risk. For use with solid wood fuel only. 2WKHU IXHOV PD\ RYHU¿UH DQG JHQHUDWH SRLVRQRXV JDVHV LH FDUERQ PRQR[LGH  Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 2: Table Of Contents

    ' 6HFXUH 2IIVHW5HWXUQ E. Install Ceiling Firestops F. Install Attic Insulation Shield * 5RRI 3HQHWUDWLRQ + ,QVWDOO &KDVH&KDVH 7RS , 7HUPLQDWLRQ &DS 5HTXLUHPHQWV - ,QVWDOO 7HUPLQDWLRQ &DS Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 3: Attention Installer

    Comments: Further description of the issues, who is responsible (Installer/Builder/Other Trades, etc.) and corrective action needed: Comments communicated to party responsible __________________________ by ______________________on _________ (Builder/Gen. Contractor) (Installer) (Date) 4059-11 • Rev $ •  Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 4: 3Urgxfw 6Shfl¿F

    State of California to cause birth defects or other reproductive harm. For more information go to: www.P65Warn- ings.ca.gov. Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 5: Getting Started

    V-shaped standoffs (spacers) Mantel and surround Decorative facing and trim Hearth extension Outside Air Factory-built fireplace (both sides) Protective metal hearth strip(s) )LJXUH  7\SLFDO )LUHSODFH 6\VWHP Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 6: Design And Installation Considerations

    (1219 mm) MINIMUM Model # 47 7/8 89 1/8 44 5/8 20 3/8 63 1/8 28 1/2 ASH36 1829 1216 2264 1133 1603 Figure 2.2 Fireplace Locations Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 7: Locating Fireplace & Chimney

    ‡ $YRLG RXWVLGH ZDOO LQ FRROHU FOLPDWHV :LQGZDUG /HHZDUG 1RW UHFRPPHQGHG LQ EDVHPHQW GXH WR KLJK QHJDWLYH SUHVVXUH FRQFHUQV Figure 2.3 Recommended Chimney Locations WKDW HIIHFW GUDIW Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 8: Tools And Supplies Needed

    Report to your dealer any parts damaged in shipment. • Read all the instructions before starting the installation. Follow these instructions carefully during the installation to ensure maximum safety DQG EHQH¿W Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 9: Framing And Clearances

    (95 mm) (129 mm) 16 1/8 in. 11 1/8 in. (408 mm) 46 7/8 in. (282 mm) (1191 mm) 16 1/8 in. (408 mm) )LJXUH  $SSOLDQFH 'LPHQVLRQV Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 10: Clearances

    1-1/2 in. (38 mm) to back & 1219 mm sides of appliance (except at nailing flanges 0 in. where it is 1/2 in. [13 mm]) to floor Figure 3.2 Clearances to Combustible Materials Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 11: Construct The Chase

    ,Q FROG FOLPDWHV WKH ZDOOV RI WKH FKDVH VKRXOG EH LQVXODWHG WR WKH OHYHO RI WKH IDOVH FHLOLQJ DV VKRZQ LQ )LJXUH  7KLV ZLOO KHOS UHGXFH KHDW ORVV IURP WKH KRPH DURXQG WKH ¿UHSODFH Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 12: Frame The Fireplace

    * If interior of chase will be drywalled, add the thickness to this measurement. ** Adjust header height for raised floor under fireplace. Figure 3.5 Framing the Fireplace Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 13: Secure And Level The Fireplace

    DO NOT install against vapor barriers or exposed insulation. • Secure insulation and vapor barriers. • Provide minimum air space clearances at the sides and EDFN RI WKH ¿UHSODFH DVVHPEO\ Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 14: Protective Metal Hearth Strips

    5HIHU WR )LJXUHV  DQG  ZKHQ SODFLQJ WKH RXWVLGH DLU inlet hoods. Note: 0D[LPXP OHQJWK LV  IHHW Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 15 • Install with short run and add a P-trap which will help for a minimum bend prevent flow of cold air. • Secure flex duct with screws or wire ties. Figure 3.8 Outside Air Installation )LJXUH  37UDS Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 16: Chimney And Termination Requirements

    18.5 ft (5.64 m) min. height single offset-return 74 1/8 in. 90 ft (27.4 m) (1884 mm) max. height Effective Height )LJXUH  &KLPQH\ 5HTXLUHPHQWV Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 17 2511 3URSHU DVVHPEO\ RI DLU FRROHG FKLPQH\ SDUWV UHVXOWV LQ DQ RYHUODS RI FKLPQH\ MRLQWV RI  LQ  PP  (IIHFWLYH OHQJWK LV EXLOW LQWR WKLV WDEOH Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 18: Termination Requirements

    In a staggered installation with both gas and wood terminations, the wood termination cap must be higher than the gas termination cap. Figure 4.3 Multiple Chimney Locations Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 19: Chimney Installation

    2 inch through ceiling or clearances. floor )LJXUH  7\SLFDO &KLPQH\ 6\VWHP  *XLGHOLQHV IRU &KLPQH\ 6\VWHP ,QVWDOODWLRQ Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 20: Assemble Chimney Sections

    9HUWLFDO VWUDLJKW UXQV RI FKLPQH\ PXVW EH VXSSRUWHG HYHU\  IW  P  Figure 5.2 Assembling Chimney Sections WARNING! Risk of Fire! DO NOT install substitute or damaged chimney components. Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 21: Secure Offset/Return

    ZKHQ WKHUH LV D URRP DERYH • Use an attic insulation shield if the ceiling is insulated. 7KH FHLOLQJ ¿UHVWRS PD\ WKHQ EH DWWDFKHG DERYH RU EHORZ the joists. Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 22: Install Attic Insulation Shield

    FHHGLQJ VHFWLRQV ,I WKH\ KDYH EHHQ FRQQHFWHG FRUUHFW- Seal with tape ly, they will not disengage when tested. )LJXUH  ,QVWDOO $WWLF ,QVXODWLRQ 6KLHOG ¿UHVWRS EHORZ FHLOLQJ Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 23: Roof Penetration

    WARNING! Risk of Fire! DO NOT caulk the pipe to the chase top collar. ‡ &DXON DOO VHDPV WR SUHYHQW OHDNV Turn-down Drip Edge Chase .018 (26 ga) min. Galvanized Chase Top )LJXUH  &KDVH 7RS &RQVWUXFWLRQ Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 24: Termination Cap Requirements

    Termination cap pipe and chimney section must be snapped together to maintain an overlap of 1-1/2 in. (38 mm). )LJXUH  ,QVWDOOLQJ D 75 7579 5RXQG 7HUPLQDWLRQ &DS Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 25 2 in. (51 mm) Chase Top 4-3/4 in. (121 mm) Chase Chimney Pipe Chase Chimney Pipe )LJXUH  ,QVWDOOLQJ D 7&7 7HUUD &RWWD &DS )LJXUH  ,QVWDOOLQJ D '72'72'76'76 &DS Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 26: Shrouds

    Flue 3 in (76 mm) air space from bottom of shroud Chase Top to top of chase. )LJXUH  6KURXG 75 6HULHV FDS ZLWK QR 5DGLDWLRQ 6KLHOG Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 27: Mailbox Style Shroud

     [  Min. Opening Width  [  Min. Height Above Bottom of Termination Cap Min. Opening Width Min. Opening Height Figure 6.5 Roofed Style Shroud Dimensions Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 28: Finishing Material

    2 in. (51 mm) Figure 7.2 Decorative Facing Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 29 965 mm) to allow for door combustible sealant. installation. The surface of the finished hearth extension and the surface of the hearth panel should be level. Figure 7.3 Facing Materials and Mortar Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 30: Hearth Extension, Building And Finishing

    0.20 10 1/2 in. Ceramic Tile 12.50 0.08  LQ $UPVWURQJŒ 3ULYDF\ *XDUG 3OXV  2.18 1 in. 14.3-20.0 0.07-0.05 29 1/2 - 41 1/4 in. 0DUEOH Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 31 SHUDWXUHV XS WR ƒ) LQ D URRP ZLWK DPELHQW WHPSHUD- WXUHV RI ƒ) &RQVXOW ÀRRULQJ VSHFL¿FDWLRQV WR HQVXUH FRPSDWLELOLW\ Non-combustible Finishing Materials Figure 7.8 Raised Platform Hearth Extension-Finishing Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 32: Raised Hearth Extension And Raised Fireplace

    6HDO JDSV EHWZHHQ WKH KHDUWK H[WHQVLRQ DQG WKH IURQW RI WKH ¿UHSODFH ZLWK D EHDG RI QRQFRPEXVWLEOH VHDODQW or grout. )LJXUH  Flush Hearth Extension Side View Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 33: Non-Combustible Sealant Material

    Measured from top of fireplace opening WARNING: Seal joint with non-combustible sealant to prevent heat from being drawn into the wall cavity. )LJXUH  0DQWHO 6SHFL¿FDWLRQV Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 34 )LJXUH  0DQWHO 6SHFL¿FDWLRQV  1RQ&RPEXVWLEOH )LJXUH  0DQWHO /HJ 6XUURXQG RU :DOO 3URMHFWLRQ DFFHSWDEOH on both sides of opening) Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 35: Install Hearth Molded Brick Panel

    Back Herringbone LH Herringbone Refractory LH Traditional Refractory Refractory Refractory Grate Grate Retainer Retainer Hearth Hearth )LJXUH  7UDGLWLRQDO 0ROGHG %ULFN 3DQHO Figure 8.2 Herringbone Molded Brick Panel Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 36: Install Screens

    F. Grate ‡ ,QVWDOO WKH JUDWH LI D JDV ORJ VHW LV QRW JRLQJ WR EH LQVWDOOHG • Position the rear grate legs into the grate retainers. Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 37 EH REVWUXFWHG LQ DQ\ PDQQHU ‡ +HDUWK +RPH 7HFKQRORJLHV UHFRPPHQGV VHFXULQJ WKH UHOLQH DW WKH WRS RI WKH ÀXH DQG XVLQJ WKH FDS FHUWL¿HG IRU XVH ZLWK WKLV ¿UHSODFH V\VWHP Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 38: Chimney Components

    'HFRUDWLYH 6KURXG   LQ [  LQ  PP [  PP 13 in. (330 mm) )LHOG &RQVWUXFWHG 6KURXGV 6HH ³:RRGEXUQLQJ 7HUPLQDWLRQ &DS´ CT-11A-B $GDSWHU0D\ EH XVHG ZLWK WKH IROORZLQJ FDSV 6/ &KLPQH\ 6WDELOL]HU CT-Series DT-Series Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 39 5) 5RRI )ODVKLQJ JB577 Chimney Joint Band 15-1/4in. (387 mm) 13 in. (330 mm) 28 in. CB576 Chimney Bracket 39-7/8 in. (711 mm) (1013 mm) 5) 5RRI )ODVKLQJ Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 40 15-3/4 in. (400 mm) TR-TVK 75  5RXQG 7HUPLQDWLRQ &DS &7$ $GDSWHU 757  5RXQG 7HOHVFRSLQJ 7HUPLQDWLRQ &DS 67  6TXDUH 7HUPLQDWLRQ &DS 7&7  7HUUD &RWWD &DS Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 41 DTS134/DTS146 DTO134/DTO146 Decorative Caps DTO134 DTO146 22.7 1168 DTS134 21.18 DTS146 21.18 1168 Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 42: Optional Components

    LDSCPM - Corner Post Kit (for custom sizes) LDS-BV Decorative Shroud Catalog # 12.5 15.5 LDS-BV ')* 6HULHV *ODVV 'RRUV (optional) See your Majestic dealer for a complete list of optional components. Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 43 This page intentionally left blank. Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...
  • Page 44  WK 6WUHHW :HVW /DNHYLOOH 01  www.majesticproducts.com 3OHDVH FRQWDFW \RXU 0DMHVWLF GHDOHU ZLWK DQ\ TXHVWLRQV RU FRQFHUQV )RU WKH ORFDWLRQ RI \RXU QHDUHVW 0DMHVWLF GHDOHU SOHDVH YLVLW ZZZPDMHVWLFSURGXFWVFRP Majestic • Ashland ASH36 Installation Manual • 4059-909 • Rev L • 7/24...