Thank you for purchasing the Long Term Thermohygrograph Model Aurora-90Ⅲ
・ This model is designed to record measured temperature and humidity for 1 month or
3 months. Do not use it for the other purposes.
・ Read this manual thoroughly before using. Keep the manual in a safe place for
future references whenever necessary.
LONG- TERM THERMOHYGROGRAPH
INSTRUCTION MANUAL
CAT No. 7012-00

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AURORA-90 III and is the answer not in the manual?

Questions and answers

Summary of Contents for SATO KEIRYOKI AURORA-90 III

  • Page 1 MODEL CAT No. 7012-00 AURORA-90Ⅲ LONG- TERM THERMOHYGROGRAPH INSTRUCTION MANUAL Thank you for purchasing the Long Term Thermohygrograph Model Aurora-90Ⅲ ・ This model is designed to record measured temperature and humidity for 1 month or 3 months. Do not use it for the other purposes. ・...
  • Page 2: Name Of Each Section

    INTRODUCTION . Roll-up type chart feeding mechanism is adopted. . This model can continuously record the measured temperature and humidity on a single roll paper for 3 months or 1 month. . The width of the chart per day is 76.8mm that makes easier to read measured value. .
  • Page 3: Operation

    . OPERATION A chart and cartridge pens are factory set. Start the operation following to instruction blow after unpacking. (1) Remove the cover. Turn the carrying handle to left until it stops. Lift the cover and remove it. (2) Remove the sponge packing material. (3) Remove the cardboard packing material that secures sensors during transportation.
  • Page 4 (7) Periodically verify the condition of battery with the battery check indicator. The criteria are as follows.  The green LED is lit : The batteries are in good condition  The red LED is lit : The batteries need to be replaced. The red LED will not be lit when the voltage decreases 1.8VDC or less.
  • Page 5 4. REPLACEMENT OF CHART ★ Mark on chart  Replace the chart within three days since the red belt printed on the lower end of the chart will come out.  Use the following specified charts. For 1-month use: No. 1L100-2050-II ii) For 3-month use: No.
  • Page 6 (7) Install take-up roll Put the center of upper disk spindle into the receptacle of upper plate pushing it toward the upper plate and put the center of spindle of lower disk into the receptacle of lower disk. Turn the lower disk slightly so that the take-up will be put into the receptacle.
  • Page 7 (12) Place the top of chart on the take-up roll  Feed the tapered end of the chart through the gap between the paper guide and timing roll, and correctly place the sprocket holes of chart over the sprockets of timing roll. ...
  • Page 8 ③ Replacement of chart When you place the sprocket holes of chart over the sprockets, be sure to mate the both ends of the sprocket holes chart are placed vertically. Be sure to use the chart specified by us. ④ Carrying instrument Before lifting the instrument, make sure that it is locked.
  • Page 9: Specifications

    7. SPECIFICATIONS Product : No. 7012-00 Long Term Thermohygrograph Model Aurora-90Ⅲ Sensors : Temperature : Bimetal strip Humidity : Human hair Measuring range : Temperature : -20 to +50°C Humidity : 0 to 100%rh Min. graduation : Temperature : 1°C Humidity : 1% Accuracy...
  • Page 10 No. 3, Nishi Fukudacho, Kanda, Chiyodaku, Tokyo 101-0037 JAPAN TEL: +81 (0)3-3254-8117 FAX: +81 (0)3-3254-8123 URL: http://www.sksato.co.jp/english/ M-01...