All brands and product names are trademarks or registered trademarks of their respective holders. This Manual introduces PowerCool-LFP-LV manufactured by SolarEast. Please read this manual before you install the product and follow the instructions carefully during the installation process. Should you have any confusion, please contact SolarEast for advice and clari昀椀cation.
CONTENTS 1 . Introduction 1.1Content and Structure of this Document This document is valid for PowerCool-LFP-LV batte爀礀 system. 1. Introduction …………………………………………………………………………………… 1 This document describes the product information, and guidance for installation, as well as APP 1.1 Content and Structure of this Document ……………………………………………… 1 con昀椀guration and commissioning.
If the batte爀礀 is stored for long time, it is required to charge it eve爀礀 six months, and the • NOTICE recom mended SOC should be 50%~55%. The batte爀礀 shall not be stored for more than 12 NOTICE indicates a situation which, if not avoided, can result in prope爀琀y damage. months if the storage temperature is -10 ~ 25℃, not more than 6 months if the storage Warning electric shock.
The 昀椀nal right of interpretation is rese爀瘀ed by 2.3.3 Wet batte爀礀 Jiangsu SolarEast Energy Storage Technology Co., Ltd. If the batte爀礀 is wet or submerged in water, do not t爀礀 to access it. Contact customer se爀瘀ice for 3.1.2 Pack...
1) Batte爀礀 Control Box Display Panel 3.2 Application scenario Click to activate/deactivate the monitor screen When the breaker is connected, press this button and hold for at least 10s to enter the force charging mode. At this time, the system main circuit is connected by force.
4.3 Installation location Make sure that the installation location meets the following conditions: The 昀氀oor is 昀氀at and level; • There are no 昀氀ammable or explosive materials nearby; • The ambient temperature is within the range from 0°C to 50°C; •...
CAUTION If the ambient temperature is out of the operating range, the batte爀礀 stops operating 3) Stack batte爀礀 packs (7 at most) on the pedestal to protect itself. The optimal temperature for the batte爀礀 pack ranges from 10°C to before placing the Batte爀礀 Control Box on top of the 40°C.
5.1 Download our APP: BAT- BAT+ APP for iOS: Open up the APP Store, type in 'SolarEast PowerCool' in the Search tab to search and download. APP for Android: Open up the Google Play, type in 'SolarEast PowerCool' in the Search tab to search and download.
Page 10
5.2.4.Click ‘get a veri昀椀cation code’ and retrieve it from the mailbox. Inse爀琀 the veri昀椀cation code 5.2.2.Click ‘Register’ and go to this page to select identity received on this page, set the password, check ‘I agree’ and click ‘Enter’. Newly registered distributor account has to be approved by the Administrator before taking e昀昀ect.
5.2.8.On this page, you can reset password by inse爀琀ing the new password twice, and then click 5.2.6.Click to switch language and go to the front page. 5.2.7.Click ‘Forget the password’ and go to this page, you may inse爀琀 the account number, obtain 5.3Viewing installed units and adding new units a veri昀椀cation code via email, input the veri昀椀cation code and click ‘Next step’.
Page 12
5.3.2.Click ‘Installations’ on the front page, you can view the systems you created. You may 5.3.4.Click any item on the system list, you will go to the ‘System information’ page, where you search by system name, email or address. may view and edit system information. 5.3.3.On the ‘system list’...
Page 13
5.3.6.Click ‘+’ on the ‘Batte爀礀 list’ page and then you may add a new device by scanning its tag 5.3.8.Scan tag code and go to ‘Add device’ page, and then click ‘Wireless connection’ for WIFI con昀椀guration.And can click on "How to Add a Device" to view the step-by-step instructions for code.
Page 14
5.3.12.Click to connect the device and wait for successful connection. After successful connec- 5.3.10.Pop-up window shows that phone WiFi is not turned on. Click “Yes”. tion, it will go to the WiFi login page. 5.3.13.Inse爀琀 account and password, click “Connect” for automatic con昀椀guration and binding. 5.3.11.Turn on WLAN on the pop-up window and click “Done”...
5.4Viewing details of installed devices 5.4.3. V iew‘ alarm data ’ 5.4.1.Click any item on the batte爀礀 list you will go to the device details page, where you can view such data as batte爀礀 SOC, batte爀礀 temperature, voltage, power, current, operating information, cell monitoring, alarm data and statistics.
Page 16
5.4.5.Power usage tracking function. You may view the statistic data of charging/discharging 5.5‘My’ page features capacity in the time span of Day/Month/Year. 5.5.1.‘My’ page features the following functions: checking personal information, viewing messages, viewing installers, viewing clients, switching language, switching temperature unit, submitting feedback and setting the system.
Page 17
5.5.3.On ‘Installer management’ page, you may view installers under your name. Click each 5.5.5.Language and temperature unit switching installer to view the details. 5.5.4.You may view client details by clicking ‘Client management’. By clicking the system list, you 5.5.6.On this page you may repo爀琀 problems encountered and view historical feedback. may view the system information.
Page 18
5.5.7.On ‘FAQ’ page you may view the list of common alarm problems. Click any item to view 5.5.9.‘About us’ pages shows company pro昀椀le and contact information of the supplier. details. 5.5.8. V iew APP version details. 5.5.10.On this page, you may change password or email address. You may also view list of shared information, log o昀昀, view se爀瘀ice agreement and privacy agreement, clear cache and cookies, and log out.
5.5.11. On ‘Account and security’ page, you may change password and email address. 5.6 Inve爀琀er selection 5.6.1.Click "My", enter "Settings" page, click "Inve爀琀er selection", and then turn on camera to scan the bar code on the Control Box and enter the con昀椀guration page 5.5.12.On account cancellation page, you are allowed to cancel your account.
5.6.3. Select the right model and click “Sta爀琀 con昀椀guring” for con昀椀guration. After a successful 6.Maintenance con昀椀guration, disconnect the device WiFi. 6.1 Capacity calibration It is better to fully charge-discharge the batte爀礀 for the capacity calibration at least once eve爀礀 six months (if available). Please conduct the calibration maintenance according to the following steps: Make sure there is a relatively stable power supply source to charge the batte爀礀...