LONGER dPOFLEX BPH01 Operating Instructions Manual

Pump head

Advertisement

Quick Links

dPOFLEX BPH01 Pump Head Operating Manual
dPOFLEX BPH01 Pump Head
Operating Manual
www.longerpump.com
1 / 11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the dPOFLEX BPH01 and is the answer not in the manual?

Questions and answers

Summary of Contents for LONGER dPOFLEX BPH01

  • Page 1 BPH01 Pump Head Operating Manual dPOFLEX BPH01 Pump Head Operating Manual www.longerpump.com 1 / 11...
  • Page 2: Table Of Contents

    3.1 Pump Head Mounting ..........................7 3.1.1 Pump Head Mounting Dimension ....................7 3.1.2 Panel Mounting ..........................7 3.1.3 Mounting on Standard Pump Drive of Longer Pump ..............8 3.2 Tubing Loading ............................9 3.2.1 Set the Tubing Clamp Position ..................... 9 3.3.2 Tubing Loading ...........................
  • Page 3: General Information

    Regularly inspect the tubing and replace it when necessary to safeguard both operators and equipment. 1.2 Repair Notes Please contact Longer Pump or its distributor, and provide the product serial number before returning the product. Products which has been contaminated with, or exposed to, toxic chemicals or any other substance hazardous to health must be decontaminated before returning to Longer Pump or its distributor.
  • Page 4: Product Introduction

    2 Product Introduction 2.1 Main Features The dPOFLEX BPH01 is a peristaltic pump head designed and manufactured by Longer Pump. The pump head is compatible with silicone tubing and Pharmed tubing in sizes 13#, 14#, 19#, 16# and 25#, and the max flow rate is 530mL/min.
  • Page 5: Specifications

    BPH01 Pump Head Operating Manual Unit: mm 2.4 Specifications Product model dPOFLEX BPH01 Outline Dimension 64mm*64mm*42mm Weight 100g Continuous flow: speed≤400rpm, Speed Range intermittent flow 400rpm<speed≤ 600 rpm Housing: IXEF Material Rollers: Nylon + molybdenum disulfide Rotor bracket: Nylon...
  • Page 6: Flow Rate

    To meet the requirements of different pressure conditions, the pump head compression block can be set for standard pressure and high pressure operation. The factory default setting is standard pressure. If a high-pressure setting is required, please inform Longer Pump or your local distributor when placing your order. Max System Pressure(MPa) Compression...
  • Page 7: Installation

    BPH01 Pump Head Operating Manual 3 Installation 3.1 Pump Head Mounting Pump Head Mounting Dimensions 3.1.1 Unit: mm 3.1.2 Panel Mounting OD of the adapter: minФ6mm, max Ф10mm Adapter 7 / 11...
  • Page 8: Mounting On Standard Pump Drive Of Longer Pump

    BPH01 Pump Head Operating Manual 3.1.3 Mounting on Standard Pump Drive of Longer Pump Mounting Bracket Mounting Bracket Adapter Pump Drive 4pcs M4x10 Cross countersunk head screws 2pcs M4x10 Hexagon socket head screws a) Mount the mounting plate on the pump drive by tightening four mounting screws (M4x10 cross countersunk head screw).
  • Page 9: Tubing Loading

    BPH01 Pump Head Operating Manual 3.2 Tubing Loading The spring-loaded tubing clamps can be set at two positions to accommodate various tubing inner diameters. Tubing Size ID (mm) Inner Position √ √ √ √ × Outer Position × ×...
  • Page 10: Tubing Loading

    BPH01 Pump Head Operating Manual (From the inner position to the outer position) (From the outer position to the inner position) 1. From the inner position to the outer position (from small tubing to large tubing) Fully open the flip cover. Place a pointed tool into the groove of the tubing clamp. Press the clamp down, then push it forward towards the front casing of the pump head.
  • Page 11 BPH01 Pump Head Operating Manual Recommended tubing length (65-70mm)  Fully open the flip cover. (Figure (1))  Check if the tubing clamp position on both sides of the pump head matches the tubing size to be loaded. If not, set the tubing clamp position accordingly. (Figure (2)) ...

Table of Contents