IMPORTANT INFORMATION:
Please read operation manual carefully before operation.
WARNING:
Tubing breakage may result in fluid sprayed from pump. Use
appropriate measures to protect operator and equipment. Please
check the tubing frequently and changing the tubing in time.
If the power line or the plug are worn or damaged please pull out
the plug (Hold the plug not the power line when pulling out).
Please shut down the power supply and pull out the plug when you
think the pump needs to be maintained or repaired.
Shut down the power supply of the pump when connecting to
external control equipment.
BT100-2J OPERATING MANUAL

Table of Contents

1
2
2
2
2
2
3
4
4
6
6
7

Advertisement

loading

Summary of Contents for LONGER BT100-2J

  • Page 1: Table Of Contents

    BT100-2J OPERATING MANUAL BT100-2J OPERATING MANUAL Table of Contents IMPORTANT INFORMATION: Please read operation manual carefully before operation. Introduction WARNING: Basic Operation Tubing breakage may result in fluid sprayed from pump. Use Start/Stop appropriate measures to protect operator and equipment. Please check the tubing frequently and changing the tubing in time.
  • Page 2: Introduction

    BT100-2J OPERATING MANUAL Basic Operation Introduction Acceptable pump heads for BT100-2J are YZ1515x, YZ2515x, YZII15, YZII25, DG-1 and DG-2. The pump delivers flow rates from 0.002 to 380 mL/min. The speed can be adjusted manually or automatically through external control interface. Store the running parameter automatically.
  • Page 3: Acceptable Pump Heads And Tubing

    0. 8- 1 0.002-32(10 ) Wall Thickness Rollers 0 - 10 KHz pulse input speed control D G - 1 Communication Control Please contact Longer Company for communication protocol. 0.0025-48(6 ) 3. 7 mm Rollers Inner Diameter ≤ 0 .8 -1 0.002-32(10 )...
  • Page 4: Maintenance

    BT100-2J OPERATING MANUAL BT100-2J OPERATING MANUAL Analog Control Show as below for external control module. If you need external control function you just insert the external control module to the 4 20 mA, 0 - 5V, 0 10V external control interface which is on the rear panel of the pump.
  • Page 5: Technical Specifications

    BT100-2J OPERATING MANUAL Technical Specifications Functions Acceptable Pump Heads: YZ1515x, YZ2515x, YZII15, YZII25, DG-1, DG-2 External Control: Start/stop, cw/ccw control and speed control (0 - 5 V, 0 - 10 V, 4 - 20 mA and 0 - 10 KHz optional)
  • Page 6 BT100-2J PERISTALTIC PUMP OPERATING MANUAL Baoding Longer Precision Pump Co.,Ltd. Building A, Chuangye Center Baoding National High - Tech Industrial Development Zone Baoding, Hebei, China 071051 Tel: 86 - 312 - 3110087 Fax: 86 - 312 - 3168553 E - mail: longer@longerpump.com Http://www.longerpump.com...