FLEXIBLE 6K●10K SINGLE PHASE – SINGLE PHASE Contents 1.Safety ..........................3 1.1 Safety notes ..........................3 1.2 Symbols used in this guide ......................3 2.Main Features ........................ 3 2.1 Summarization ..........................3 2.2 Functions and Features ........................ 3 3.Installation ........................4 3.1 Unpack checking ...........................
FLEXIBLE 6K●10K SINGLE PHASE – SINGLE PHASE 1. Safety Important safety instructions – Save these instructions There exists dangerous voltage and high temperature inside the UPS. During the installation, operation and maintenance, please abide the local safety instructions and relative laws, otherwise it will result in personnel injury or equipment damage.
FLEXIBLE 6K●10K SINGLE PHASE – SINGLE PHASE -stage: Constant Voltage In order to vitalize battery and make sure batteries are fully charged stage: Floating mode. With this 3-stage charging method, it extends the life of the batteries and guarantees fast charging. LCD Display ◆...
FLEXIBLE 6K●10K SINGLE PHASE – SINGLE PHASE Side View 3.3 LCD control panel LCD control panel introduction (1) INVERTER LED (2) BATTERY LED (3) BYPASS LED (4) ALARM LED (5) LCD display (6) UP button (7) DOWN button (8) ESC /OFF button (9) ENTER/ON button 3.4 Installation notes ◆Please place the UPS in a clean, stable environment, avoid the vibration, dust, humidity, flammable gas and liquid, corrosive objects.
FLEXIBLE 6K●10K SINGLE PHASE – SINGLE PHASE ◆Batteries should be mounted in an environment where the temperature is within the required specs. Temperature is a major factor in determining battery life and capacity. In a normal installation, the battery temperature is maintained between 15°C and 25°C. Keep batteries away from heat sources or main air ventilation area, etc.
FLEXIBLE 6K●10K SINGLE PHASE – SINGLE PHASE 3.6 Power Cables ◆ The cable design shall comply with the voltages and currents provided in this section, Kindly follow local wiring practices and take into consideration the environmental conditions (temperature and physical support media) .
FLEXIBLE 6K●10K SINGLE PHASE – SINGLE PHASE WARNING If the load equipment is not ready to accept power on the arrival of the commissioning engineer then ensure that the system output cables are safely isolated at their ends CAUTION The earthing and neutral bonding arrangement must be in accordance with local and national codes of practice.
FLEXIBLE 6K●10K SINGLE PHASE – SINGLE PHASE 3.9 UPS Multi - Module Installation The basic installation procedure of a parallel system comprising of two or more UPS modules is the same as that of single module system. The following sections introduce the installation procedures specified to the parallel system.
FLEXIBLE 6K●10K SINGLE PHASE – SINGLE PHASE 3.9.3 Requirement for the parallel system A group of paralleled modules behave as one large UPS system but with the advantage of presenting higher reliability. In order to assure that all modules are equally utilized and comply with relevant wiring rules, please follow the requirements below: 1) All UPS must be of the same rating and be connected to the same bypass source.
FLEXIBLE 6K●10K SINGLE PHASE – SINGLE PHASE 4. Operation 4.1 Operation Modes The UPS is a double-conversion on-line UPS that may operate in the following alternative modes: ◆ Normal mode The rectifier/charger derives power from the AC Mains and supplies DC power to the inverter while floating and boosting charge the battery simultaneously.
FLEXIBLE 6K●10K SINGLE PHASE – SINGLE PHASE 4.2.2 Black (Cold) start procedure CAUTION Follow these procedures when the input AC Utility Failure, but battery is normal. ◆ Turn on the battery switch. The battery will feed the Auxiliary power board. ◆...
FLEXIBLE 6K●10K SINGLE PHASE – SINGLE PHASE 4.3 LCD Display instruction NOTICE! The display provides more functions than those described in this manual. Below the available interfaces in the LCD display: ITEM INTERFACE DESCRIPTION CONTENT DISPLAYED Input Voltage & Frequency Output Voltage &...
FLEXIBLE 6K●10K SINGLE PHASE – SINGLE PHASE Press “DOWN” button, the UPS goes to next page as shown below. (2) Input voltage (3) Output voltage (4) Bat + voltage (Positive) (5) Bat – voltage (Negative) (6) Load (7) PFC/ Ambient temperature up, only shows the high temperature Internal temperature (down) (8) Bus voltage...
FLEXIBLE 6K●10K SINGLE PHASE – SINGLE PHASE 4.4.1 Mode setting Mode setting (Note: Inside the broken-line is the flashing part) After ENTERing the setting menu, it’s mode setting defaulted, and the mode setting line flashing as in above picture. • Use button ENTER /ON to choose different mode.
FLEXIBLE 6K●10K SINGLE PHASE – SINGLE PHASE To change the Output frequency before you need to change the Mode setting (4.4.1) following this instruction: UPS must stay in By-pass mode (press OFF key for 1-2 sec to Turn OFF the inverter) 1) Press together UP and DOWN for 2 sec to open the Menu 2) Scroll the Menu with UP or DOWN keys to select 01 (MOD) and press ENTER.
FLEXIBLE 6K●10K SINGLE PHASE – SINGLE PHASE • Press ESC/OFF button to exit the battery quantity setting (save the battery quantity setting) and goes to battery capacity setting or bypass voltage upper limit setting. 4.4.6 Bypass Volt-Hi setting Bypass voltage upper limit setting (Note: Inside the broken-line is the flashing part) When under the battery quantity setting press DOWN or when under bypass voltage lower setting press UP, it goes to the bypass upper limit setting.
FLEXIBLE 6K●10K SINGLE PHASE – SINGLE PHASE Press DOWN under bypass voltage lower limit setting or press UP under the parallel ID setting can ENTER the buzzer setting. Now the setting status is flashing as the Figure shows (note: on=mute; off= no mute). When press, it shows the mute cycle setting, the selection includes ON and OFF.
FLEXIBLE 6K●10K SINGLE PHASE – SINGLE PHASE 4.4.10 Parallel ID setting Parallel ID setting (Note: Inside the broken-line is the flashing part) When under the bypass voltage lower limit setting press DOWN or when under parallel quantity setting press UP, it goes to the parallel ID setting.
FLEXIBLE 6K●10K SINGLE PHASE – SINGLE PHASE Appendix 4 UPS message table This section lists the alarm messages that the UPS might display. This section is listed with each alarm message to help you troubleshoot problems. 4.1 Alarm Information ITEM UPS ALARM WARNING BUZZ Rectifier Fault...