Page 1
COTES LIGHTWEIGHT USER MANUAL How to install, set up, operate and service your Cotes Lightweight dehumidifier Original instructions COTES LIGHTWEIGHT - USER MANUAL 1/18 Cotes dehumidifier: CL26 Manual number: 140778 Revision: A COTES.COM...
Cotes A/S has no obligation to inform buyers of the Maintenance must be carried out according to the products and equipment of such subsequent instructions in the SERVICE AND MAINTENANCE changes.
This handbook is mainly intended for use by technicians who install and operate this Cotes dehumidifier unit, who carry out preventive maintenance and who replace defective parts.
+/- 300 Pa Foreseeable misuse Unless specifically stated in the user manual or in a separate agreement with Cotes or a Cotes Partner, this dehumidifier must not be used for the following purposes: Conditioning of gases other than atmospheric air at ambient pressure.
Regeneration Air Outlet Dry Air Outlet The effectiveness of Cotes adsorption dehumidifiers basically stems from the action (or interaction) of two air flows. In this case, one fan controls the air, and it is expelled later in the drying process.
Filter (Standard - G4) See section 6 / SERVICE AND MAINTENANCE for information on how to access main components. Optional accessories Cotes Lightweight dehumidifiers can be fitted with the following optional accessories: DESCRIPTION Analogue hygrostat (Cotes DR10). Cotes Window Kit...
If the dehumidifiers have been delivered on a transport pallet, they can be moved using a forklift. Cotes dehumidifiers are built to be very durable so there is no need for any special handling other than normal reasonable care and attention. But do not stand on it or use it as a stool/staircase.
Installation above sea level: Max. 3000 meter. Where not to mount it Unless it has been arranged with Cotes and special considerations have been made, the unit should not be placed outdoors. The unit should not be placed inside an office or in other locations where the sound pressure level must be kept to a minimum.
First, make sure that the selector switch is in position 0. Now the power cable can be connected to the mains. Cotes Lightweight dehumidifiers are suitable for 230V-50Hz, 1PH+N+PE power supply. The dehumidifier is supplied with build in socket for different cable length and plug for the power supply.
Low Energy High Capacity Fast installation: Potentiometer setting More accurate installation Regeneration air /hour Power consumption Optimal installation: Dry air /hour Regeneration air /hour Power consumption COTES LIGHTWEIGHT - USER MANUAL 11/18 Cotes dehumidifier: CL26 Manual number: 140778 Revision: A COTES.COM...
Page 12
When a potentiometer is also installed, the adjustment of the dehumidifier is an iterative process. NOTE: The energy consumption of the electric heater in the first seconds is up to 10A depending on the setup. COTES LIGHTWEIGHT - USER MANUAL 12/18...
NOTE Only trained or authorised electricians are allowed to carry out any work required in the electrical parts of this Cotes dehumidifier. Ensure the power supply is switched off at the mains switch when the cover of the electrical box is open.
Mode switch Program selector switch 5.2 HOW TO OPERATE THIS DEHUMIDIFIER Cotes Lightweight dehumidifiers are designed for maximum dehumidification and the standard setting is continuous operating time. This configuration is intentionally simple, with no dehumidification management installed. Starting and stopping the dehumidifier...
Service and maintenance work on this dehumidifier Cotes designs its dehumidifier units so that they are as robust as possible, requiring only minimal service and maintenance. None of the components require lubrication or adjustment. The only maintenance work you need to do is listed below.
Page 16
Drive belt for rotor 25.000 Rotor 42.000 The above limits should be considered as guidelines only, as the actual and required times will depend on the working environment COTES LIGHTWEIGHT - USER MANUAL 16/18 Cotes dehumidifier: CL26 Manual number: 140778 Revision: A COTES.COM...
Page 17
'teeth' is held correctly. Do not use a lot of force. When all the teeth on both sides are in place, you can use force on the top and fix the lid with the 4 screws. COTES LIGHTWEIGHT - USER MANUAL 17/18...
6.2 TROUBLESHOOTING Before contacting Cotes Technical Support, please review the list of possible problems below. This list is helpful in identifying faults that can often be remedied without the assistance of qualified personnel. Table 3 Troubleshooting. PROBLEM POSSIBLE CAUSE SOLUTION The external fuse has turned off.
Need help?
Do you have a question about the LIGHTWEIGHT CL26 and is the answer not in the manual?