1. Button Functions
Home Button: Return to the previous menu or main interface
Knob: Adjust device settings
Start / Stop Button: Start / Stop delivering air
2. Setting up the Device
A. Connect one end of the tube to the assembled mask.
B. Connect one end of the tube to the air outlet of the device, as shown in the figure above. Or
Connect the heated tubing joint to the air outlet of the device, and then insert the power plug of
the heated tubing into the heated tubing port on the back of the device.
Note: To apply the tubing elbow adapter, connect the tubing elbow adapter between the device
air outlet and the tubing (heated or standard tubing) as shown in the figure above. The 90
degree elbow helps to direct the tubing.
C. Connect the power adapter to the DC inlet of the main device.
D. Connect the power cord to the power adapter.
E. Plug the power cord into the power outlet.
F. If the disposable ultra-fine filter is used, place the reusable air filter first, the reusable air filter
should be closest to the filter cap and the disposable ultra-fine filter should be closest to the
device. Install the filter cap containing the reusable air filter / disposable ultra-fine filter to the
device.
Note:
The reusable air filter should be replaced at least every 6 months and the disposable ultra-fine
filter should be replaced at least every 2 weeks. Replace the filters more often if there are any
holes or blockages by dirt or dust.
The disposable ultra-fine filter is not washable or reusable.
Luna
®
G3 BPAP 25A (LG3700) Patient Quick Set-Up Guide
G3 BPAP 25A (LG3700)
®
Patient Quick Set-Up Guide
1 / 4

Advertisement

loading
Need help?

Need help?

Do you have a question about the Luna G3 BPAP 25A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for React Health Luna G3 BPAP 25A

  • Page 1 Luna ® G3 BPAP 25A (LG3700) Patient Quick Set-Up Guide Luna G3 BPAP 25A (LG3700) ® Patient Quick Set-Up Guide 1. Button Functions Home Button: Return to the previous menu or main interface Knob: Adjust device settings Start / Stop Button: Start / Stop delivering air 2.
  • Page 2 Luna ® G3 BPAP 25A (LG3700) Patient Quick Set-Up Guide 3. Removing the Water Chamber Press down the water chamber, and then remove it, as shown in the figure. WARNING! • Turn the device off and allow the heating plate and water to cool for approximately 15 minutes before removing the Water Chamber.
  • Page 3 Luna ® G3 BPAP 25A (LG3700) Patient Quick Set-Up Guide E. Press the Knob to confirm your adjustment to the option. F. The cursor switches among the options as you turn the Knob , as shown in the figure below. Refer to steps C-E to adjust other options. Press the Home Button to exit the Setup Interface.
  • Page 4 If AHI is less than 5, it scores 20 points, when AHI ≥ 5 and for every 5 increase in AHI, 4 points is deducted. <5 10-14 15-19 20-24 ≥25 Score REACT HEALTH • 5101 Fruitville Rd. • Suite 200 Sarasota, FL 34232 • (863) 226-6285 • www.reacthealth.com V1.2 YF-nP3-2-43-123 4 / 4...

This manual is also suitable for:

Lg3700