Luna II CPAP / Luna II Auto CPAP User Manual ® ® 1. Introduction Thank you for your purchase of the Luna II CPAP / Luna II Auto CPAP. This User ® ® Manual will provide you with information about your device. Please read it carefully. If you experience any difficulties or problems during use, please contact your homecare provider or physician.
Page 5
Luna II CPAP / Luna II Auto CPAP User Manual ® ® Manufacturer Disassembly is prohibited Batch Code Non-Ionizing Radiation SD Card Marking of Electrical and Electronic Equipment Air Inlet Air Outlet Made in China MR Unsafe Complies with RTCA DO-160 section 21, category M. Caution Medical Device Prescription only...
Page 6
Luna II CPAP / Luna II Auto CPAP User Manual ® ® Temperature Limit Humidity Limit Atmospheric Pressure Limit 3 / 43...
Luna II CPAP / Luna II Auto CPAP User Manual ® ® 3. Warning, Caution and Important Tip WARNING! Indicate the possibility of injury to the user or operator. CAUTION! Indicate the possibility of damage to the device. IMPORTANT TIP! Indicate the possibility that such operation may affect the effectiveness or ease of use of the device.
Luna II CPAP / Luna II Auto CPAP User Manual ® ® • Cleaning can be performed by the patient. IMPORTANT TIP! • Read and understand the entire user manual before operating this system. If you have any questions concerning the use of this system, contact your home care provider or health care professional.
Luna II CPAP / Luna II Auto CPAP User Manual ® ® 6. Specifications Device Size Dimensions: 274 mm × 184 mm × 115 mm Weight: 1.9 kg Water capacity: To maximum fill line 360 mL Product Use, Transport and Storage Operation Transport and Storage Temperature: 5°...
Page 10
Luna II CPAP / Luna II Auto CPAP User Manual ® ® Ramp The ramp time ranges from 0 to 60 minutes. The A-weighted sound pressure level and sound power level When the device is working at the pressure of 10 hPa, its sound pressure level and sound power level shall not be greater than the values in the following table: Sound Pressure Uncertainty...
Luna II CPAP / Luna II Auto CPAP User Manual ® ® 7. Available Therapies The device delivers the following therapies: CPAP – Delivers Continuous Positive Airway Pressure; CPAP maintains a constant level of pressure throughout the breathing cycle. If your health care professional has prescribed ramp for you, you can press the Ramp Button to reduce the pressure and then gradually increase the pressure to the therapeutic pressure setting so that...
Luna II CPAP / Luna II Auto CPAP User Manual ® ® Patient Menu The display mode in which you can change patient-adjustable device settings, such as the starting pressure for the Ramp feature. Ramp A feature that may increase patient comfort when therapy is started. It begins from a low pressure and then gradually increases to the prescribed setting pressure so that the patient can fall asleep more comfortably.
• Do not connect any equipment to the device unless recommended by REACT HEALTH or your health care provider. • Please contact REACT HEALTH to obtain an SD card if needed. • Exceeding the Expected Service life, our company cannot guarantee the normal function of the device, nor the safety and effectiveness of the device.
Luna II CPAP / Luna II Auto CPAP User Manual ® ® 11. System Features Display Screen Humidifier Indicator Mute Button Power Indicator Knob Ramp Button Fig. 11-1 Name Function Indicate the humidity level. There are five levels in total. The number of indicator lights that light up is directly Humidifier Indicator proportional to the humidity level.
Luna II CPAP / Luna II Auto CPAP User Manual ® ® SD Card Slot Communications Port Air Outlet DC Inlet Filter Cap (Air Inlet) Fig. 11-2 Name Function SD Card Slot Insert the SD card into this slot Air Outlet Deliver pressurized air;...
Luna II CPAP / Luna II Auto CPAP User Manual ® ® inhaled or swallowed. • To avoid explosion, this device must not be used in the presence of flammable gases (e.g. anesthetics). • Tobacco smoke may cause tar build-up within the device, leading to the malfunctioning of the device.
Luna II CPAP / Luna II Auto CPAP User Manual ® ® DC Inlet Power Adapter Power Cord Fig. 12-3 WARNINGS! • The device is powered on for use when the power cord and power adapter is connected. The Knob turns the blower On / Off.
• In order to minimize the risk of CO rebreathing, the patient should observe the following instructions: - Use the accompanying tube and mask provided by REACT HEALTH. - Do not wear the mask for more than a few minutes while the device is not operating.
Page 19
Luna II CPAP / Luna II Auto CPAP User Manual ® ® • When the pressure valve is installed, the Auto On function on the device will not work. To turn on the device either breath into your mask or select the On/Off button. •...
Luna II CPAP / Luna II Auto CPAP User Manual ® ® 12.6 Inserting the SD Card (Only for the device that equipped with SD card) Insert the SD card into the SD Card Slot, as shown in Fig. 12-5. SD Card Slot Fig.
• DO NOT connect any ancillary equipment to this device unless recommended by REACT HEALTH or your physician. If you suffer from chest discomfort, shortness of breath, stomach bloating, or severe headache when using the device, contract your physician or qualified medical personnel immediately.
Luna II CPAP / Luna II Auto CPAP User Manual ® ® CAUTION! • Observe the water level of the water chamber before using the humidifier. Make sure there is sufficient water in the water chamber, and avoid heating the device with an empty water chamber.
Luna II CPAP / Luna II Auto CPAP User Manual ® ® Fig. 14-1 WARNING! • Turn the device off and allow approximately 15 minutes for the heater plate and water to cool. 14.1.2 Filling Water Open the cap, as shown in Fig. 14-2, and fill the water chamber with approximately 360 mL of water, as shown in Fig.
Luna II CPAP / Luna II Auto CPAP User Manual ® ® 14.1.3 Inserting the Water Chamber Close the cap after it is filled with water, as shown in Fig. 14-4, and return it to the device, as shown in Fig. 14-5.
Luna II CPAP / Luna II Auto CPAP User Manual ® ® CAUTION! • Empty and air-dry the water chamber when the device is not in use. (3) Inserting the Water Chamber according to instructions in 14.1.3. 14.3 Setting the Humidity Level After the device is powered on, turn the Knob to turn on or turn off the heated humidifier and to adjust the humidity level according to instructions on the screen of...
Luna II CPAP / Luna II Auto CPAP User Manual ® ® 15. Navigating the Patient Menu 15.1 Steps to Navigating the Patient Menu 15.1.1 Accessing the Main Interface Connect the power cord and power adapter properly. The screen displays the Main Interface shown in Fig.
Luna II CPAP / Luna II Auto CPAP User Manual ® ® 15.1.3 Accessing the Setup Interface When the cursor is on the icon , the screen displays the Setup Interface. Access the Setup Interface by pressing the Knob . The first option on the Setup Interface is then displayed in blue, as shown in Fig.
Luna II CPAP / Luna II Auto CPAP User Manual ® ® 15.1.6 Confirming Adjustments Confirm your adjustment to an option by pressing the Knob . The option is then displayed in blue, as shown in Fig. 15-7. Fig. 15-7 15.1.7 Turning Pages When the cursor is on Brightness, the last option shown in Fig.
Page 29
Luna II CPAP / Luna II Auto CPAP User Manual ® ® Fig. 15-10 (2) Returning to the Main Interface Move the cursor to the Home option by turning the Knob , as shown in Fig. 15-11. Fig. 15-11 Press the Knob to exit the Patient Menu.
Luna II CPAP / Luna II Auto CPAP User Manual ® ® 15.2 Options of the Patient Menu and Corresponding Descriptions Option Range Description There are five humidity levels available. As the numbering increases, humidity rises Off, 1 ~ 5 Humidifier accordingly.
(nasal pillow mask). The patient can choose Mask Type Nasal; other suitable masks as well. When selecting Pillow; Other masks other than the above three types of REACT HEALTH masks, the patient can identify the masks as other iCode provides access patient's iCode, compliance data during a recent time period.
Luna II CPAP / Luna II Auto CPAP User Manual ® ® 17. Cleaning WARNINGS! • Cleaning the device and its accessories as recommended in the following sections is essential to prevent respiratory infections. • To avoid electric shock, always unplug the device before cleaning. •...
Luna II CPAP / Luna II Auto CPAP User Manual ® ® 17.1 Cleaning the Mask and Headgear For details, refer to the cleaning instructions in the user manual for the mask. 17.2 Cleaning the Cellular Module Wipe the surface of the Cellular Module with a clean, soft, and slightly damp cloth. CAUTION! •...
Luna II CPAP / Luna II Auto CPAP User Manual ® ® CAUTIONS! • Clean the water chamber only after the water in it cools. Make sure that no water enters the device. • After cleaning, rinse the water chamber throughly in clean water to make sure that no soap residue is left;...
18. Traveling 18.1 Traveling with the Device (1) Use the REACT HEALTH carrying case to carry the device and accessories along with you. Do not put them in your checked baggage. (2) This device operates on power supplies of 100 V - 240 V and 50 Hz / 60 Hz, and is suitable for use in any country in the world.
20. Technical Support Please contact REACT HEALTH directly if you need the circuit diagram of the device and the list of components for certain purposes such as maintenance or connection to other equipment. REACT HEALTH will provide the circuit diagram and / or other technical documents in whole or in part according to your needs.
Luna II CPAP / Luna II Auto CPAP User Manual ® ® 22.1 Common Problems in Patients and Corresponding Solutions Problem Possible Cause Solution (s) The nose reacts to the Increase the humidity setting airflow and cold. Due to Dry, cold, runny, of the device.
Page 38
Luna II CPAP / Luna II Auto CPAP User Manual ® ® Problem Possible Cause Solution (s) Contract your home care Wrong mask size provider correct-size mask Contact your physician and Facial home care provider. reddening The patient is allergic to the Use a mask which is not made materials of the mask with natural rubber latex.
Luna II CPAP / Luna II Auto CPAP User Manual ® ® 22.2 Common Problems in the Device and Corresponding Solutions Problem Possible Cause Solution (s) Take a few deep breaths with The Auto On / Off the mask on, and the device feature is enabled will start automatically Ensure that the power cord,...
Luna II CPAP / Luna II Auto CPAP User Manual ® ® 23. EMC Requirements Guidance and manufacturer's declaration - electromagnetic emissions The device is intended for use in the electromagnetic environment specified below. The user of the device should ensure that it is used in such an environment.
Page 41
Luna II CPAP / Luna II Auto CPAP User Manual ® ® Guidance and manufacturer's declaration - electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The user of the device should make sure that it is used in such an environment.
Page 42
Luna II CPAP / Luna II Auto CPAP User Manual ® ® Guidance and manufacturer's declaration - electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The user of the device should make sure that it is used in such an environment.
Page 43
Luna II CPAP / Luna II Auto CPAP User Manual ® ® Recommended separation distances between portable and mobile RF communications equipment and the device The device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the device as recommended below, according to the...
Page 44
Luna II CPAP / Luna II Auto CPAP User Manual ® ® Recommended separation distances between RF wireless communications equipment The device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the device can help prevent electromagnetic interference by maintaining a minimum distance between RF wireless communications equipment and the device as recommended below, according to the maximum output power of the...
Page 45
Luna II CPAP / Luna II Auto CPAP User Manual ® ® WARNINGS! • The device should not be used in the vicinity or on the top of other electronic equipment such as cell phone, transceiver or radio control products. If you have to do so, the device should be observed to verify normal operation.
® 24. Limited Warranty REACT HEALTH warrants that the device shall be free from defects of workmanship and materials and will perform in accordance with the product specifications for a period of two (2) years for main unit and three (3) months for all accessories from the date of sale by REACT HEALTH to the dealer.