Victron & Pylontech UP2500, US2000, US3000, US2000C, US3000C, US5000, US5000B, UF5000, Pelio-L, UP5000,
2024-11-04 10:06 1/16
Victron & Pylontech UP2500, US2000,
US3000, US2000C, US3000C, US5000,
US5000B, UF5000, Pelio-L, UP5000,
Phantom-S, Force-L1 & L2
The combination of Victron products with Pylontech lithium batteries has been tested and certified by
the Victron and Pylontech R&D departments.
General information about the battery is found in Pylontech's documentation.
This manual is intended to be used in conjunction with the product manual supplied by Pylontech. It
provides additional and specific information regarding integration with Victron systems.
The Pylontech includes a Battery Management System (BMS) with each battery module. This
interfaces with the Victron
1. Product & system compatibility
Battery UP2500*
Nominal
24V
voltage
Module
2.55 kWh
capacity
Minimum
Venus
v3.50
firmware
24V: UP2500 48V: US2000, US3000, US2000C, US3000C, US5000, US5000B, UP5000, Phantom-S,
Force-L1 & L2 51.2V: Pelio-L, UF5000
* Note that UP2500 came in two versions, UP2500NA01V00101 does not have a CANBUS port, and IS
NOT supported by Victron. UP2500NB01V00101 released April 2020 has the CANBUS port and IS
Victron Energy - https://www.victronenergy.com/live/
GX device
and can support multiple battery modules connected in parallel.
US2000
US3000(C)
(Plus/C)
48V
48V
2.4 kWh
3.5 kWh
v3.50
v3.50
UP5000 &
Pelio-L
US5000(B)
48V
51.2V
4.8 kwh
5.12kWh 3.55 kWh
v3.50
v3.50
Phantom-S, Force-L1 & L2
Force-L1 &
UF5000
L2
48V
51.2V
Coming
soon
v3.50
v3.50

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Pylontech UF5000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Victron Pylontech UF5000

  • Page 1 US3000, US2000C, US3000C, US5000, US5000B, UF5000, Pelio-L, UP5000, Phantom-S, Force-L1 & L2 The combination of Victron products with Pylontech lithium batteries has been tested and certified by the Victron and Pylontech R&D departments. General information about the battery is found in Pylontech's documentation.
  • Page 2 1.4 All VE.Direct BlueSolar and SmartSolar MPPT Chargers are compatible For proper operation, the Pylontech battery needs to be able to control the charge current. Therefor it is recommended to use Victron 48V compatible MPPTs models with VE.Direct port for charging. MPPTs with a VE.Direct port MPPTs are controlled via the device.
  • Page 3 Victron & Pylontech UP2500, US2000, US3000, US2000C, US3000C, US5000, US5000B, UF5000, Pelio-L, UP5000, 2024-11-04 10:06 3/16 Phantom-S, Force-L1 & L2 (due to temperature, etc) To test operation, try disconnecting the GX device from the MPPT. After a time-out, the MPPT will stop charging and flash an error code on its LEDs. The error code is error #67: BMS.
  • Page 4: Can-Bus Wiring

    Larger batteries using an LV-Hub is discussed later in this document. Type A cable The Victron VE.Can to CAN-bus BMS type A Cable, part number ASS030710018 is used for connection with US2000C / US3000C / UP5000 / US5000 / US5000B / Force-L. https://www.victronenergy.com/live/...
  • Page 5 Phantom-S, Force-L1 & L2 Type B cable The Victron VE.Can to CAN-bus BMS type B Cable, part number ASS030720018 is used for connection with US2000 / US3000 / UP2500; Note you cannot use the comms cable supplied by Pylontech for this connection between the master battery and the GX device.
  • Page 6 Last update: battery_compatibility:pylontech_phantom https://www.victronenergy.com/live/battery_compatibility:pylontech_phantom 2024-11-04 09:43 After properly wiring and setting the correct CAN-bus speed, the Pylontech will be visible as a battery in the device list. If you have multiple batteries a single entry will show up, which represents all batteries: Next, go to Settings, DVCC, and configure as follows: Venus Settings →...
  • Page 7 Victron & Pylontech UP2500, US2000, US3000, US2000C, US3000C, US5000, US5000B, UF5000, Pelio-L, UP5000, 2024-11-04 10:06 7/16 Phantom-S, Force-L1 & L2 communicated to the DVCC system by the BMS. The 'charge current limit' (CCL) as shown in the parameters screen (and received from the BMS, by the GX device, via DVCC) will be the ceiling, and the system will try its best not to exceed that (as much as it can - it may spike under momentary peaking conditions).
  • Page 8 Target Battery Voltage, etc) are automatically configured by the Pylontech BMU, and communicated to the rest of the Victron components in the system via DVCC. It is possible to override some of these automatic settings to provide additional limitations (e.g.
  • Page 9 Victron & Pylontech UP2500, US2000, US3000, US2000C, US3000C, US5000, US5000B, UF5000, Pelio-L, UP5000, 2024-11-04 10:06 9/16 Phantom-S, Force-L1 & L2 This section presumes familiarity with VEConfigure software. Voltages shown are for the 48V model, and should be scaled for the 24V model. The 24V model is an 8-series configuration while the 48V model is a 15-series configuration.
  • Page 10 Last update: battery_compatibility:pylontech_phantom https://www.victronenergy.com/live/battery_compatibility:pylontech_phantom 2024-11-04 09:43 guide Design and Installation Manual. The settings that are specific to the Pylontech battery in the VEConfigure ESS Assistant are below: Select the externally managed Lithium battery option ESS Parameter Settings Sustain voltage. Dynamic cut-off values set all values to 46V. Restart offset: 1.2V (Default) Due to the reliability of the grid supply and the behaviour of the sustain voltage threshold in ESS;...
  • Page 11: Example Wiring Diagram

    Victron & Pylontech UP2500, US2000, US3000, US2000C, US3000C, US5000, US5000B, UF5000, Pelio-L, UP5000, 2024-11-04 10:06 11/16 Phantom-S, Force-L1 & L2 6. VE.Direct MPPT Settings In normal operation the MPPT charge characteristics are governed by the GX device via DVCC, with instructions from the connected Pylontech battery.
  • Page 12: Troubleshooting

    Last update: battery_compatibility:pylontech_phantom https://www.victronenergy.com/live/battery_compatibility:pylontech_phantom 2024-11-04 09:43 8. Troubleshooting If the system is not operating correctly, go through these steps. Step 0. If the Inverter/Charger or GX device does not switch on When the grid is connected there are two software controls to sustain voltage. The Minimum SOC (while grid is connected) set in the GX device, and the sustain voltage (set in the ESS assistant).
  • Page 13 If its not visible, check: GX device firmware version (update to latest version, v2.15 or later) CAN-bus communication cabling between Pylontech and Victron system. Make sure that it is in the right way around. Pylontech system is up and running (LEDs are on) Step 2.
  • Page 14 Pylontech's BMS will restrict the Charge Current Limit of the battery in cold weather. The precise temperatures and limits are not published by Pylontech, but anecdotally from reports on Victron Community it would appear that batteries begin to be limited below 18 degree C, severely limited below 10 degrees C, and completely restricted from charging below 2 degrees C.
  • Page 15 Victron & Pylontech UP2500, US2000, US3000, US2000C, US3000C, US5000, US5000B, UF5000, Pelio-L, UP5000, 2024-11-04 10:06 15/16 Phantom-S, Force-L1 & L2 none of the capacity and greatly improves the stability of the system. The battery won't charge to 100% Also see the question above. The state of charge of the battery is estimated based on the overall voltage and on how well balanced the internal cells are.
  • Page 16: Further Information

    Please discuss large Pylontech systems that require the LV-Hub with your experienced Pylontech agent FIRST. These additional LV-Hub references are provided without any support or endorsement from Victron, and should not be assumed to be up to date. Defer to your experienced dealers recommendations.