Acond Aconomis S Installation Manual

Heat pump - air - water
Hide thumbs Also See for Aconomis S:

Advertisement

Quick Links

Installation manual
Acond Aconomis
Acond Aconomis S, N, R
Heat Pump - air - water
Installation manual
Date of last change: 08.08.2024
Page 1/32
AC-A036-EN-R01
For partners

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Aconomis S and is the answer not in the manual?

Questions and answers

Summary of Contents for Acond Aconomis S

  • Page 1 Installation manual Acond Aconomis Acond Aconomis S, N, R Heat Pump - air - water Installation manual Date of last change: 08.08.2024 Page 1/32 AC-A036-EN-R01 For partners...
  • Page 2: Table Of Contents

    Installation manual Acond Aconomis Compressor oil ..............19 Explanation of symbols, validity of documentation ............3 Hydraulic connection ........19 Symbols used ..............3 Protective measures ........19 Validity of documentation ..........3 Access to the outdoor unit ......20 Important information ........
  • Page 3: Explanation Of Symbols, Validity Of Documentation

    Failure to comply with these instructions during installation, operation and maintenance will void ACOND a.s.'s obligations under the warranty. ACOND a.s. reserves the right to change parts of the documentation and specifications without prior notice. © 08/2024 Copyright ACOND a.s.
  • Page 4: Important Information

    Installation manual Acond Aconomis Important information If the installation is not used in winter or cannot be started up for operational reasons (e.g. due to a serious malfunction) and is not filled with antifreeze, the water must be drained from the heating system, otherwise there is a risk of frost damage to the installation.
  • Page 5: Treatment Of The Device

    Installation manual Acond Aconomis No handling of open flames near the outdoor unit! 2.1.3 Treatment of the device Do not use chlorine to treat painted and stainless steel surfaces and avoid abrasive materials and wire! Treat lacquered and polycarbonate surfaces with a damp cloth and detergent and then wipe the surface dry with a soft cloth.
  • Page 6: Risk Of Injury Due To Frost

    Installation manual Acond Aconomis Electric current warning • Only carry out all electrical installation work and electrical connections in accordance with national and local regulations. • The connection to the mains must be made as a fixed connection only. •...
  • Page 7: Water Quality And Volume

    Installation manual Acond Aconomis 2.3.1 Water quality and volume All water (including heating water) must meet the parameters for drinking water according to ČSN 252/2004 Coll., but in addition the maximum total hardness must be below 1.25 mmol/l, the chloride content below 85 mg/l and the pH between 6.8 and 8.0.
  • Page 8: Technical Data

    Installation manual Acond Aconomis Technical data Table 2: Technical data Model Acond Aconomis Acond Aconomis Acond Aconomis Compressor Double rotary Double rotary Double rotary EDTN180D32EFZ EDTM310D85EMT WHP37600PSKTQ9JK Voltage code; protection*) 1~N/PE/230V/50Hz; B16A 1~N/PE/230V/50Hz; B16A 3~N/PE/400V/50Hz; B16A Maximum current [A] Starting current current [A] <5...
  • Page 9 For the stated maximum losses of each model, it is necessary that the bivalent controlled source has a minimum power for model S - 5kW, for model N - 9kW. Table 3: Performance parameters Model Acond Aconomis S Acond Aconomis N Acond Aconomis R *)**)
  • Page 10: Dimensional Drawing Of The Heat Pump

    Installation manual Acond Aconomis Dimensional drawing of the heat pump Image 1: Dimensional drawing of the heat pump Table 4: Dimensional drawing Type Acond Aconomis S Acond Aconomis N Acond Aconomis R V [mm] W [mm] 1060 1210 H [mm]...
  • Page 11: Manipulation

    Installation manual Acond Aconomis Manipulation More than one person must be working while the equipment is being handled. The weight of the equipment must be taken into account, see Table 2. The equipment must be transported to the installation site packed and secured on a wooden pallet. For handling of the equipment are the holes shown in red, see Image 2into which, for example, hooks are inserted.
  • Page 12: Place Of Installation

    Installation manual Acond Aconomis Place of installation For all work carried out: • It is necessary to comply with the regulations in force at the site, legal regulations, regulations and guidelines. • Respect the noise data see Image 3. Sound pressure values (A7/W55) are measured according to EN 12 102-1...
  • Page 13: Information At The Place Of Operation

    There shall be no sources of ignition such as sockets, light poles, lamps or electrical switches in the protection zone, see Image 4. Protection zone Protection zone Image 4 Dimension Acond Aconomis S Acond Aconomis N Acond Aconomis R 3060 3210 2060...
  • Page 14: Foundation For The Heat Pump

    Ensure that the outdoor unit will not disturb neighbours. The condensate drain flows freely into a properly prepared subfloor. Image 5: Base under Aconomis S without stool under heat pump Image 6: Base under Aconomis S with stool under heat pump Date of last change: 08.08.2024...
  • Page 15 Installation manual Acond Aconomis Image 7: Base under Aconomis N without stool under heat pump Image 8: Base under Aconomis N with stool under heat pump Date of last change: 08.08.2024 Page 15/32 AC-A036-EN-R01 For partners...
  • Page 16 Installation manual Acond Aconomis Do not place the unit in windy locations where it would be exposed to direct gusts of strong wind. Such placement reduces fan performance, thereby impairing the efficiency of the heat pump and increases the evaporator defrost time. When installed in a section exposed to wind the wind must be prevented from significantly affecting the fan section.
  • Page 17: Fixing The Heat Pump

    If a stool other than the supplier's stool is used, the stool used must ensure safe operation of the heat pump! Back side Front side Image 9: Bottom view - mounting holes Table 5: Dimensions for pump mounting Type Acond Aconomis S Acond Aconomis N Acond Aconomis R A [mm] B [mm] C [mm] W [mm]...
  • Page 18: Condensate Drainage

    Installation manual Acond Aconomis Condensate drainage If the recommended design of the foundation for the outdoor heat pump unit is followed, the condensate formed on the evaporator is drained into the subsoil and frosting in the vicinity of the heat pump is minimised (see Image 10).
  • Page 19: Compressor Oil

    The compressor oil charge is designed to last the lifetime of the equipment. It can only be changed in the event of compressor or refrigeration circuit failures. Table 6: Compressor oil Model Acond Aconomis S Acond Aconomis N Acond Aconomis R PAG VG60...
  • Page 20: Access To The Outdoor Unit

    Installation manual Acond Aconomis Access to the outdoor unit Wrap the grommets with mineral wool or otherwise seal the hole around the grommet (e.g. with foam). Do not use mounting foam, which transmits vibrations from the outdoor unit when it hardens! To connect the outdoor unit to a piece of equipment located inside the heated building, a 120mm diameter hole must be punched.
  • Page 21: Heat Pump Installation

    Installation manual Acond Aconomis • Check whether the electrical insulation resistance is higher than 1MΩ by measuring the resistance between the protective conductor and the phase conductors. This test is only carried out on the interconnecting conductors. If you measure a lower resistance, try to find the cause.
  • Page 22: Installation Of The Accumulation Vessel

    Installation manual Acond Aconomis 12.1 Installation of the accumulation vessel The heating system may be fitted with a stainless steel vessel designed for heating water storage or a stainless steel hot water storage tank (hereinafter referred to as vessels), which must be installed and operated in accordance with the instructions in this documentation.
  • Page 23: Instructions For Operation, Maintenance And Servicing Of The Dhw Tank And Storage Vessel

    Installation manual Acond Aconomis In the case of connecting the grounding of the container to a line that has not been validly inspected, the manufacturer shall not be liable for any injuries resulting from the operation of the container so installed, nor for any damage that may occur to the container.
  • Page 24: Connecting The Communication Cable

    Installation manual Acond Aconomis 12.4 Connecting the communication cable Insulate the shielding wire of the communication cable carefully, do not connect. In case of interference problems, connect only at one point of the installation, preferably in the indoor unit (in the switchboard) to the PE ground terminal.
  • Page 25 Installation manual Acond Aconomis • A login interface appears to enter a username and password - ask the service department for the details Image 14: Pairing - step 1 • after logging in you will be prompted to pair the outdoor unit with the indoor unit and to set the type of sensors fitted (see label in the indoor unit) and to set the type of CH (see Image 14) •...
  • Page 26 Installation manual Acond Aconomis Image 16: Pairing - step 3 • enter the address of the room thermostat (under the bottom cover of the respective thermostat) and click on STEP 3 OK, another table will appear (see Image 17). Image 17: Pairing - step 4 •...
  • Page 27 Installation manual Acond Aconomis The pump service page is displayed, see Image 18. In the upper right corner of the web interface we can change the language. Image 18: Service page In case of connection problems, the IP address of the control unit can be found on its display. On the control board, see Image 19, you need to press the Mode button and then the down arrow.
  • Page 28: System Parameters

    Installation manual Acond Aconomis 13.2.1 System parameters Logging in with the service login will take you directly to the service page of the pump. If you leave to the home user page, you can get back to the service environment via the screwdriver icon and wrench icon in the bottom right corner.
  • Page 29 Installation manual Acond Aconomis Parameter Meaning of AL01 Temperature difference T01 and T02 for flow alarm (A16) AL02 Flow Failure Delay (A16) BI06 Biv 1 allowed BI07 Biv 2 allowed RM01 Desired room temperature 1. circuit RM02 Radiators - hysteresis RM01 RM06 Flooring - max.
  • Page 30: Verification Of Heat Pump Functions

    Installation manual Acond Aconomis SY23 0 -> without AKU, 1 -> with AKU SY27 0 -> without Solar, 1 -> with Solar SY30 0 -> system without pool, 1 -> system with pool SY28 0 → radiators installed in the 1st heating circuit 1 →...
  • Page 31: Setting The Desired Control

    Installation manual Acond Aconomis Turn on the compressor, enter the speed in manual mode (again M in the blue square next to the desired speed value and confirm with an arrow or entree) and watch the water temperature at the outlet of the CH rise, the HP value rise and the LP and suction values fall.
  • Page 32: Disposal

    Installation manual Acond Aconomis 14.1 Disposal The technician responsible for removal from the system must be familiar with all the details of equipment disposal. It is recommended to drain the refrigerant from the circuit. In order to reuse the refrigerant, the used refrigerant must be free of dirt, oil residues, etc.

This manual is also suitable for:

Aconomis nAconomis r

Table of Contents