Page 1
24" Roof Exhauster Fan Bin Accessories Installation, Operation, and Parts Manual Read this manual before using product. Failure to Part Number: 018223 R10 follow instructions and safety precautions can Revised: July, 2024 result in serious injury, death, or property Original Instructions damage.
Page 2
New in this Manual The following changes have been made in this revision of the manual Description Section Updated Section 2.9 – Safety Decal Locations and Details on page 10 Updated Section 4.2 – Installing the Roof Exhauster Fan on page 13 Section 9.
Page 3
This product has been designed and manufactured to meet general engineering standards. Other local regulations may apply and must be followed by the operator. All personnel must be trained in the correct operational and safety procedures for this product. Use the sign-off sheet below to record initial and periodic reviews of this manual with all personnel.
Page 4
24" ROOF EXHAUSTER FAN – BIN ACCESSORIES 018223 R10...
1.1.1 Explosion Proof Roof Exhauster Information AGI grain bin Roof Exhauster Fans have been designed to operate in a hazardous agricultural environment as defined by the United States National Electric Code (NEC), Article 500 Class I, Div. 1, Group D and Class II, Div. 1, Groups F and G.
2. SAFETY 24" ROOF EXHAUSTER FAN – BIN ACCESSORIES 2. Safety 2.1. Safety Alert Symbol and Signal Words This safety alert symbol indicates important safety messages in this manual. When you see this symbol, be alert to the possibility of injury or death, carefully read the message that follows, and inform others.
2. SAFETY 24" ROOF EXHAUSTER FAN – BIN ACCESSORIES 2.3. Fan Safety • Keep away from fan impeller/blade; high suction can pull a person toward the inlet. Contact with an unguarded impeller/blade will cause severe injury. • Keep the inlet screen in place at all times. •...
2. SAFETY 24" ROOF EXHAUSTER FAN – BIN ACCESSORIES 2.5. Safety Equipment The following safety equipment should be kept on site. • First-Aid Kit Have a properly-stocked first-aid kit available for use should the need arise, and know how to use it. 2.6.
ID logo decal AGI logo decal warranty registration decal 018223 R10...
Page 11
2. SAFETY 24" ROOF EXHAUSTER FAN – BIN ACCESSORIES Table 1. Safety Decals Item Description Part Number CNA-1393 R0 601-1992 NOTICE To prevent possible roof damage, ensure that all roof vents are open and unobstructed. Do not operate aeration fan if it is possible that the roof vents could ice up.
• Verify that the supply voltage is correct. Report missing or damaged parts immediately to ensure that proper credit is received from AGI or your distributor/dealer, and to ensure that any missing parts can be shipped quickly to avoid holding up the installation.
4.2. Installing the Roof Exhauster Fan Important Due to the variations of sheets (both AGI and non-AGI), fit must be determined through adjusting placement of the fan. Note that this should be done as part of roof assembly, not after sidewall construction.
Page 14
4. INSTALLATION 24" ROOF EXHAUSTER FAN – BIN ACCESSORIES Figure 1. Minimum Clearance between Fan and Roof Ribs 5. Mark the location of each of the holes in the back panel (XZA-2674) flashing onto the roof sheet. 6. Mark the location of at least 3 holes in the collar/base of enclosure onto the roof sheet. 7.
Page 15
4. INSTALLATION 24" ROOF EXHAUSTER FAN – BIN ACCESSORIES Figure 2. Field Cut or Drilled Holes 3/8" [10mm] THRU 5mm MIN 3/16" MIN 3/8" [10mm] THRU 11. Cut out the aeration hole along the tracing for the collar. Note Cut the opening all around about 1/8" (3 mm) larger than the collar opening but stay at least 3/16" (5 mm) from the holes.
Page 16
4. INSTALLATION 24" ROOF EXHAUSTER FAN – BIN ACCESSORIES Figure 4. Sealing Around Opening and Holes in Roof Sheet Sealer Tape (532-3698) 14. Apply sealer tape both sides of the bolt holes on the roof sheet. 15. Lower the fan onto the roof sheet. 16.
Page 17
4. INSTALLATION 24" ROOF EXHAUSTER FAN – BIN ACCESSORIES Figure 5. Align Flashing Backer with Holes in Back Panel 19. Apply caulking (sold separately) as necessary. 20. After adjacent roof sheets are installed, bolt the fan supports to the roof sheet roof ribs. See Figure Note There are 4 fan supports on the Roof Exhauster Fan;...
Page 18
Wire equipment motor through a circuit breaker or fused disconnect switch. Important • AGI assumes no liability for incorrect wiring of the fan. Installers and owner are fully responsible for correctly wiring and grounding this equipment. • Fan controls are not supplied by AGI.
In the United States: Ensure proper electrical ground in accordance with NFPA 70 (National Fire Protection Association). • AGI recommends that grain bin electrical devices be connected to a ground rod that is no further than 8' (2440 mm) away from the bin foundation.
5. OPERATION 24" ROOF EXHAUSTER FAN – BIN ACCESSORIES 5. Operation For optimal operation, follow these safety precautions, checklists, and instructions. 5.1. Operation Safety • Ensure the fan inlet, outlet, bin floor ductwork and roof vents are not plugged with any foreign material.
5. OPERATION 24" ROOF EXHAUSTER FAN – BIN ACCESSORIES 5.3. Ventilation • Ensure that the Roof Exhauster Fans are electrically interlocked with aeration fans to prevent the possibility of fans operating independently. • Adequate ventilation and/or “makeup air” devices should be provided for all powered air handling systems. Make certain aeration fans always push more air into the bin than Roof Exhauster Fans are pulling out.
• After maintenance is complete, replace all guards, service doors, and/or covers. • Use only genuine AGI replacement parts or equivalent. Use of unauthorized parts will void warranty. If in doubt, contact AGI or your local dealer. 6.2. Maintenance Schedule Follow the Maintenance Schedule below.
6. MAINTENANCE 24" ROOF EXHAUSTER FAN – BIN ACCESSORIES 6.3. Visually Inspect the Roof Exhauster Fan Check the following during a visual inspection: 1. Ensure all guards are in place and in good working order. 2. Check that the outlet guard is free of debris. 3.
The following section covers some causes and solutions to some of the problems that may be encountered. If there is a problem that is difficult to solve, even after having read through this section, please contact your representative or AGI. Have this manual and the serial number available. Cause Problem Solution Turn power on at source.
Page 25
7. TROUBLESHOOTING 24" ROOF EXHAUSTER FAN – BIN ACCESSORIES Problem Cause Solution Fan runs for a short Excessively high amps Check voltage and phase balance. Correct time then shuts off. electrical power if needed, otherwise repair or replace motor. Control box is in the sun on a Shade the control box and / or provide very hot day.
8. SPECIFICATIONS 24" ROOF EXHAUSTER FAN – BIN ACCESSORIES 8. Specifications 8.1. Model Specifications Table 2. 24" (60.96 cm) Roof Exhauster Fan Model Specifications Voltage (V) Fan Models Phase Other GGE-80211A 1.49 208-230 GGE-80211AH 1.49 208-230 • Explosion-Proof GGE-80232A 1.49...
Page 29
9. PARTS 24" ROOF EXHAUSTER FAN – BIN ACCESSORIES Table 5. Roof Exhauster Fan Housing (XZA-7647/XZA-7648) Parts (quantities not shown) Part Number Description With single phase, With all other XP motor motors 006366 006356 MOTOR MOUNT TOP 006364 006357 MOTOR MOUNT BOTTOM 202-3720 COLLAR XZA-2675...
Tighten all bolts to the torque specified, unless otherwise noted. Check tightness periodically, using Table 7 as a guide. Replace the hardware with the same strength bolt, contact AGI if you are unsure. Table 7. Recommended Bolt Torque Recommended Torque (ft-lb) Threads...
11. WARRANTY 24" ROOF EXHAUSTER FAN – BIN ACCESSORIES 11. Warranty AGI (the Company) makes the following warranty to the initial retail purchaser of its products (the Customer). Materials and Workmanship The Company warrants products manufactured by it to be free from defects in materials and workmanship in normal use and service for a period of one (1) year after date of delivery to the Customer.
Page 32
AGI is a leading provider of equipment solutions for agriculture bulk commodities including seed, fertilizer, grain, and feed systems with a growing platform in providing equipment and solutions for food processing facilities. AGI has manufacturing facilities in Canada, the United States, the United Kingdom, Brazil, South Africa, India and Italy and distributes its products globally.
Need help?
Do you have a question about the GGE-80211A and is the answer not in the manual?