MaxStream 9 XTend OEM Product Manual

MaxStream 9 XTend OEM Product Manual

Rf module
Hide thumbs Also See for 9 XTend OEM:

Advertisement

Quick Links

Chipsmall Limited consists of a professional team with an average of over 10 year of expertise in the distribution
of electronic components. Based in Hongkong, we have already established firm and mutual-benefit business
relationships with customers from,Europe,America and south Asia,supplying obsolete and hard-to-find components
to meet their specific needs.
With the principle of "Quality Parts,Customers Priority,Honest Operation,and Considerate Service",our business
mainly focus on the distribution of electronic components. Line cards we deal with include
Microchip,ALPS,ROHM,Xilinx,Pulse,ON,Everlight and Freescale. Main products comprise
IC,Modules,Potentiometer,IC Socket,Relay,Connector.Our parts cover such applications as commercial,industrial,
and automotives areas.
We are looking forward to setting up business relationship with you and hope to provide you with the best service
and solution. Let us make a better world for our industry!
Contact us
Tel: +86-755-8981 8866 Fax: +86-755-8427 6832
Email & Skype: info@chipsmall.com Web: www.chipsmall.com
Address: A1208, Overseas Decoration Building, #122 Zhenhua RD., Futian, Shenzhen, China
  

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 9 XTend OEM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MaxStream 9 XTend OEM

  • Page 1 Chipsmall Limited consists of a professional team with an average of over 10 year of expertise in the distribution of electronic components. Based in Hongkong, we have already established firm and mutual-benefit business relationships with customers from,Europe,America and south Asia,supplying obsolete and hard-to-find components to meet their specific needs.
  • Page 2: Xte Nd™ Oem Rf M Odu Le

    For OEM RF Module Part Num bers t hat begin wit h: XT09- R..., XT09- M... 1 W a t t Tr a n sm it Pow e r , 2 5 6 - bit AES En cr ypt ion MaxStream 355 Sout h 520 West , Suit e 180...
  • Page 3: Com M A N D D E Scr Ipt Ion

    9XTend™ OEM RF Module ‐ Product Manual v2.x4x [2007.01.04] © 2 0 0 7 M a x St r e a m , I n c. All r igh t s r e se r ve d The contents of this manual may not be transmitted or reproduced in any form or  by any means without the written permission of MaxStream, Inc. XTend™ is a trademark of MaxStream, Inc. AES Encryption Source Code © 2007 Dr. Brian Gladman, Worcester, UK. All rights reserved. Conditions:  ‐ Distributions of AES source code include the above copyright notice, this list of  conditions and disclaimer. ‐ Distributions in binary form include the above copyright notice, this list of con‐ ditions and disclaimer in the documentation and/or other associated materials. ‐ The copyright holderʹs name is not used to endorse products built using this ...
  • Page 4: Table Of Contents

    4.2.3. Repeat er Mode 47 4.2.4. Polling Mode ( Basic) 50 4 .3 . Ack n ow le dge d Com m u n ica t ion s 5 1 4.3.1. Acknowledged Mode 51 4.3.2. Polling Mode ( Acknowledged) 53      iii © 2007 MaxStream, Inc., Confidential & Proprietary ‐ All Rights Reserved ...
  • Page 5: Xtend Oem Rf Module

    9XTend OEM RF Modules are opt im ized for use in t he US, Ca n a da , Au st r a lia a nd I sr a e l ( cont act MaxSt ream for com plet e list of agency approvals) .      4 © 2007 MaxStream, Inc.
  • Page 6: Spe Cifica T Ion S

    3.0 - 5.5 VDC 4.75 - 5.5 VDC Transmit Current (5 V) typical 110 mA 140 mA 270 mA 500 mA 730 mA Transmit Current (3.3 V) typical 90 mA 110 mA 260 mA 600 mA * If the supply voltage for a given power setting is lower than the minimum supply voltage requirement (as shown in Table 1‐02), the  TX Power Output will decrease to the highest power level setting given the current supply voltage. ** 1W Power Output is not supported when using a 3.3 supply voltage.      5 © 2007 MaxStream, Inc.
  • Page 7: Pin Sign A Ls

    Refer to the RP Command [p35] for more information. 12-20 reserved / do not connect *  RF module has 10K Ω internal pull‐up resistor Note: When integrating the module with a Host PC board, all lines not used should be left disconnected (floating).      6 © 2007 MaxStream, Inc.
  • Page 8: Ele Ct R Ica L Ch A R A Ct E R Ist Ic

    Time starting when CTS goes low until 44 µ sec 75 µ sec CLDL the first bit appears on DOUT Time after last bit of data until 7 µ sec 7 µ sec CHDH CTS goes high      7 © 2007 MaxStream, Inc.
  • Page 9: M E Ch A N Ica L D R A W In Gs

    - 0.7V (-IO = 6 mA) Output High Voltage SUPPLY Figure 1‐04. Input Thresholds vs. Supply Voltage Input thresholds vs. supply voltage V(IL) V(IH) 1 .5 . M e ch a n ica l D r a w in gs Figure 1‐05. Mechanical drawings of the XTend OEM RF Module (w/RPSMA Connector)  Figure 1‐06. Mechanical drawings of the XTend OEM RF Module (w/MMCX Connector)       8 © 2007 MaxStream, Inc.
  • Page 10: Rf Module Operation

    Serial com m unicat ions depend on t he t wo UARTs t o be configured wit h com pat i- ble set t ings ( baud rat e, parit y, st art bit s, st op bit s, dat a bit s) .      9 © 2007 MaxStream, Inc.
  • Page 11: Flow Cont Rol

    Soft w a r e Flow Con t r ol ( XOFF) . XON/ XOFF soft ware flow cont rol can be enabled using t he FL ( Soft ware Flow Cont rol) Com m and. This opt ion only works wit h ASCI I dat a.      10 © 2007 MaxStream, Inc.
  • Page 12: Transparent Operat Ion

    Change dest inat ion addresses wit hout having t o ent er com m and m ode - > Receive success/ failure st at us of each RF packet - > I dent ify t he source address of each received packet To implement API operations, refer to ‘API Operation’ sections [p40].      11 © 2007 MaxStream, Inc.
  • Page 13: M Ode S Of Ope R A T Ion 1

    ( up t o 2048 byt es in each packet , refer t o PK Com m and) , convert ed t o RF dat a and is t ransm it - t ed over- t he- air unt il t he DI buffer is em pt y.      12 © 2007 MaxStream, Inc.
  • Page 14 CRC on all incom ing RF dat a. Received dat a t hat has an invalid CRC is discarded [ refer t o t he ‘Receive Mode’ sect ion] .      13 © 2007 MaxStream, Inc.
  • Page 15: Receive Mode

    Note: Because the DO pin also goes high impedance, if the XTend RF Module is connected to a pro- cessor, the UART receive pin could be floating. A weak pull-up should be placed between the module and the microcontroller so that data is not interpreted as being transmitted to the microprocessor.      14 © 2007 MaxStream, Inc.
  • Page 16: Sleep Mode

    Sleep Mode and rem ains in it s lowest power- consum ing st at e unt il t he pin is de- assert ed. This pin is only act ive if t he m odule is set up t o operat e in t his m ode; ot herwise t he pin is ignored.      15 © 2007 MaxStream, Inc.
  • Page 17 The cyclic interval time defined by the SM (Sleep Mode) command must be shorter than the interval time defined by LH (Wake-up Initializer Timer) command. Figure 2‐08. Correct Configuration (LH > SM):  The length of the wake‐up initializer exceeds the time interval of Cyclic Sleep. The receiver is  guaranteed to detect the wake‐up initializer and receive the accompanying payload data.      16 © 2007 MaxStream, Inc.
  • Page 18: Com M And Mode

    [ OR] Send ATCN ( Exit Com m and Mode) Com m and. For an example of programming the RF module using AT Commands and descriptions of each config- urable parameter, refer to the "RF Module Configuration" chapter [p19].      17 © 2007 MaxStream, Inc.
  • Page 19 ‘1’), the module will not recognize that the CMD pin is asserted and therefore will not recognize the data as binary commands. Refer t o [ p19] for a binary program m ing exam ple ( DT com m and exam ple ret urns t wo byt es) .      18 © 2007 MaxStream, Inc.
  • Page 20: Rf Module Configuration

    De- assert CMD ( pin 10 is driven low) . ( Exit Binary Com m and Mode) Note: CTS (pin 9) is high when a command is being executed. Hardware flow control must be disabled as CTS will hold off parameter bytes.      19 © 2007 MaxStream, Inc.
  • Page 21 0 - 4 Serial Interfacing PB v2.x20* 0x45 (69d) Polling Begin Address 0 - 0xFFFF Networking & Security 0 - 0xFFFF PD v2.x20* 0x47 (71d) Minimum Polling Delay Networking & Security (Base: (x 1 ms), Remote: [x 10 ms])      20 © 2007 MaxStream, Inc.
  • Page 22 Firmware Version - verbose Returns string Diagnostics 0x14 (20d) Firmware Version 0 - 0xFFFF [read-only] Diagnostics Active Warning Numbers Returns string Diagnostics Warning Data Returns string Diagnostics 0x08 (8d) Write (Special) Sticky Warning Numbers Returns string Diagnostics * Firmware version in which command and parameter options were first supported      21 © 2007 MaxStream, Inc.
  • Page 23 AT Com m and Mode. Refer t o t he ‘AT Com m and Mode’ sect ion [ p17] for m ore inform at ion regarding t he AT Com m and Mode Sequence.      22 © 2007 MaxStream, Inc.
  • Page 24 Binary Command: 0x39 (57 decimal) t ransm it t ed over- t he- air) of t he m odule. Parameter Range: 0 - 1 Baud (bps) Parameter Configuration 9600 115200 Default Parameter Value:1 Number of bytes returned: 1      23 © 2007 MaxStream, Inc.
  • Page 25 HV ( Hardware Version) commands may output units KY ( AES Encrypt ion Key) All commands forced to unsigned, unit-less hex Commands utilize their default number base; no units are output Default Parameter Value: 1 Number of bytes returned: 1      24 © 2007 MaxStream, Inc.
  • Page 26 NOTE: I f t he DB regist er is read before t he m odule has received an RF packet , t he m odule will ret urn a value of 0x8000 ( which m eans an RF packet has not yet been received) .      25 © 2007 MaxStream, Inc.

Table of Contents