Summary of Contents for MaxStream 9XCite XC09-009 Series
Page 1
Distributor of Digi International: Excellent Integrated System Limited Datasheet of XC09-009-DK - KIT DEV FOR 900MHZ 9600BPS 1MW Contact us: sales@integrated-circuit.com Website: www.integrated-circuit.com Excellent Integrated System Limited Excellent Integrated System Limited Stocking Distributor Stocking Distributor Click to view price, real time Inventory, Delivery & Lifecycle Information: Click to view price, real time Inventory, Delivery &...
Page 2
Advanced Networking Appendices Product Manual v2.1 For RF Module Part Numbers: XC09-009… XC09-038… Low Power, Low Cost OEM RF Modules by MaxStream, Inc. MaxStream 355 South 520 West, Suite 180 Lindon, UT 84042 Phone: (801) 765-9885 Fax: (801) 765-9895 rf-xperts@maxstream.net M100043 www.MaxStream.net (live chat support)
9XCite™ OEM RF Module – Product Manual v2.1 [2007.01.04] 2.1.3. Serial Data Data enters the MaxStream RF module through the DI Pin as an asynchronous serial signal. The signal should idle high when no data is being transmitted. The UART performs tasks (such as timing and parity checking) needed for communication. Serial communication consists of two UARTs which must be configured with compatible parameters (Baud rate, parity, start bits, stop bits, data bits) to have successful communication.
Mode. The return into Idle Mode is triggered by the de-assertion of the Sleep pin or the arrival of a serial byte through Data In pin. The following table lists MaxStream's Sleep Mode configurations and the requirements needed to transition into and out of Sleep Mode: Table 2‐01.
• 900 MHz, 38400 Baud, Single Channel mode XCite Modems can operate in both Single Channel and Hopping modes. Mode is selectable using the "Function Set" dropdown list of the "XCite Configuration" tab of the MaxStream-provided X- CTU Software. The XCite Module is shipped with a unique parameter set in its memory. Parameters within the set are organized under the following categories: AT Commands &...
A shortcut for editing PC Setting values is available by clicking on any of the values. Installation Double-click the "setup_X-CTU.exe" file and follow prompts of the installation screens. This file is located in the 'software' folder of the MaxStream CD and also under the 'Downloads' section of the following web page: www.maxstream.net/support/downloads.php Setup To use the X-CTU software, a module assembly (An RF module mounted to an interface Board) must be connected to a serial port of a PC.
Page 25
ID (Modem VID) Parameter <Non-AT Settable Parameter: Networking> ID Parameter reads and edits the module's VID. VID is a MaxStream-specific acronym that stands for "Vendor Identification Number". RF modules can only communicate with other modems having the same VID. Parameter Range: 0 - 0x7FFF (above this range is Read-only)
Only modems with matching VIDs can communicate with each other. VID addressing ensures that radio modems ignore transmissions and receptions of XCite Radio Modems having a different VID in the same vicinity. To request a unique VID, contact MaxStream to obtain the VID Request Form.
The XCite OEM RF Module complies with Part 15 of the FCC rules and regulations. Compliance with the labeling requirements, FCC notices and antenna usage guidelines is required. In order to operate under MaxStream’s FCC Certification, OEMs/integrators must comply with the following regulations: The OEM/integrator must ensure that the text provided with this device [Figure A-01] is placed on the outside of the final product and within the final product operation manual.
Section 15.203 (unique antenna connectors) and Section 15.247 (emissions). Fixed Base Station and Mobile Applications MaxStream RF Modules are pre-FCC approved for use in fixed base station and mobile applica- tions. When the antenna is mounted at least 20cm (8") from nearby persons, the application is considered a mobile application.
900 MHz Radio Modems (including "Mag Mount", "Dome", "Multi-path" and "Panel" antennas). Because of the large number of approved antennas, MaxStream requests that you send specific information about an antenna you would like to use with the modem and MaxStream will evaluate whether the antenna is covered under our FCC filing.
1-year from the date of purchase. In the event of a product failure due to materials or workmanship, MaxStream will repair or replace the defec- tive product. For warranty service, return the defective product to MaxStream, shipping prepaid, for prompt repair or replacement.
Datasheet of XC09-009-DK - KIT DEV FOR 900MHZ 9600BPS 1MW Contact us: sales@integrated-circuit.com Website: www.integrated-circuit.com 9XCite™ OEM RF Module – Product Manual v2.1 [2007.01.04] Contact MaxStream Free and unlimited technical support is included with every MaxStream Radio Modem sold. For the best in wireless data solutions and support, please use the following resources: Documentation: www.maxstream.net/support/downloads.php Technical Support: Phone.
Need help?
Do you have a question about the 9XCite XC09-009 Series and is the answer not in the manual?
Questions and answers