Page 1
Assembly and Operating Manual APS-Z80 Analog position sensor Translation of Original Operating Manual...
Page 2
Imprint Imprint Copyright: This manual is protected by copyright. The author is SCHUNK SE & Co. KG. All rights reserved. Technical changes: We reserve the right to make alterations for the purpose of technical improvement. Document number: 1598569 Version: 01.00 | 07/08/2024 | en...
7 Declaration of conformity ............... 13 8 UKCA Declaration of Conformity ..............14 9 Information on the RoHS Directive, REACH Regulation and Substances of Very High Concern (SVHC) ..................15 01.00 | APS-Z80 | Assembly and Operating Manual | en | 1598569...
If the product is used as intended, the warranty is valid for 24 months from the ex-works delivery date under the following conditions: Observe the applicable documents, } 1.1.2 [/ 4] Observe the ambient conditions and operating conditions, } 2.3 [/ 5] 01.00 | APS-Z80 | Assembly and Operating Manual | en | 1598569...
Modifications, changes or reworking, e.g. additional threads, holes, or safety devices, can damage the product or impair its functionality or safety. Structural changes should only be made with the written approval of SCHUNK. 01.00 | APS-Z80 | Assembly and Operating Manual | en | 1598569...
Before working with the product, the personnel must have read and understood the complete assembly and operating manual. Observe the national safety regulations and rules and general safety instructions. 01.00 | APS-Z80 | Assembly and Operating Manual | en | 1598569...
If the product is used as intended, the warranty is valid for 24 months from the ex-works delivery date under the following conditions: Observe the applicable documents, } 1.1.2 [/ 4] Observe the ambient conditions and operating conditions, } 2.3 [/ 5] 01.00 | APS-Z80 | Assembly and Operating Manual | en | 1598569...
Ambient temperature [°C] Min. - 20 Max. + 80 Nominal voltage [VDC] Min. Max. IP rating More technical data is included in the catalog data sheet. Whichever is the latest version. 01.00 | APS-Z80 | Assembly and Operating Manual | en | 1598569...
Do not exceed the permitted bending radius of the cable. Do not allow the sensor to come into contact with hard objects and chemicals (e. g., nitric acid, chromic acid and sulfuric acid). 01.00 | APS-Z80 | Assembly and Operating Manual | en | 1598569...
As a result, the maximum possible resolution of the sensor is not reached. This ensures that a saturation effect never occurs in any application scenario. 01.00 | APS-Z80 | Assembly and Operating Manual | en | 1598569...
The sensor is influenced by a Same or similar product Increase the distance different sensor. between the sensors to at least 2 mm. 01.00 | APS-Z80 | Assembly and Operating Manual | en | 1598569...
Page 12
The higher the exposure to such fluids, the more often it needs to be cleaned. NOTE If these steps do not eliminate the problem, contact SCHUNK Service for troubleshooting. 01.00 | APS-Z80 | Assembly and Operating Manual | en | 1598569...
Signed for and on behalf of: SCHUNK SE & Co. KG Lauffen/Neckar, August 2024 i.V. Nico Peper; Director Software and Electronics;Technology & Innovation 01.00 | APS-Z80 | Assembly and Operating Manual | en | 1598569...
Marcel Machado, address: refer to manufacturer's address Signed for and on behalf of: SCHUNK SE & Co. KG Lauffen/Neckar, August 2024 i.V. Nico Peper; Director Software and Electronics;Technology & Innovation 01.00 | APS-Z80 | Assembly and Operating Manual | en | 1598569...
"on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS)", or fulfill their intended function only as part of one. Therefore products from SCHUNK do not fall within the scope of the directive at this time. REACH Regulation Products from SCHUNK fully comply with the regulations of Regulation (EC) No. 1907/2006...
Page 16
SCHUNK SE & Co. KG Spanntechnik | Greiftechnik | Automatisierungstechnik Bahnhofstr. 106 - 134 D-74348 Lauffen/Neckar Tel. +49-7133-103-0 info@de.schunk.com schunk.com Folgen Sie uns I Follow us Wir drucken nachhaltig I We print sustainable...
Need help?
Do you have a question about the APS-Z80 and is the answer not in the manual?
Questions and answers
sensing range
The sensing range of the SCHUNK APS-Z80 is from 0.5 V to 9.5 V analog output, corresponding to the jaw position of the gripper.
This answer is automatically generated