  • Page 1 September 2024 / Bulletin 100-50-13.1 Bulletin 100-50-13.1 – Page 1 Sporlan PSD5 Interface Board GC/FGB Valve Driver Installation and Operation Instructions...
  • Page 2: Table Of Contents

    OFFER OF SALE The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated in the detailed “Offer of Sale” available at www.parker.com.
  • Page 3: Safety Information

    Please Note Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Parker for any consequences arising out of the use of this material. A qualified person is one who has skills and knowledge related to the construction and operation of electrical equipment and its installation, and has received safety training to recognize and avoid the hazards involved.
  • Page 4 Any use other than that expressed above under Intended use is strictly prohibited. Liability and Residual Risks The liability of Parker is limited to the correct and professional use of the product according to the directives referred to herein and in the other supporting documents, and does not cover any damage (including but not limited to) the following causes: •...
  • Page 5: Loss Of Control

    Gas Cooler/Flash Gas Bypass Valves Bulletin 100-80 You can download these technical publications and other technical information from our website at https://discover.parker.com/Sporlanliterature WARNING LOSS OF CONTROL • When applying this equipment, consider the potential failure modes of control paths and for any critical control functions.
  • Page 6: Introduction

    Page 6 – Bulletin 100-50-13.1 2. INTRODUCTION GENERAL INFORMATION The PSD5 is a small valve positioner that extends the functionality of an external system controller to drive Sporlan Gas Cooler and Flash Gas Bypass valves. The external controller must provide an analog 0-10vdc or 4-20mA signal to the PSD5.
  • Page 7: Operating Environment

    Bulletin 100-50-13.1 – Page 7 OPERATING ENVIRONMENT This equipment has been designed to operate outside of any hazardous location and exclusive of application that generate, or have the potential to generate, hazardous atmospheres. Only install this equipment in zones and applications known to be free, at all times, of hazardous atmospheres.
  • Page 8: Installation

    Page 8 – Bulletin 100-50-13.1 3. INSTALLATION DIN RAIL MOUNTING DIN Rail mounting of the PSD5V1SD-010 and PSD5V1SD-420: 1. Move the lower locking clip at the bottom outwards as shown in the diagram below (lever with a screwdriver or similar tool). Be sure to keep the upper locking clip located on top fully inserted. 2.
  • Page 9: Panel Mounting

    Bulletin 100-50-13.1 – Page 9 PANEL MOUNTING Panel mounting the PSD5V1SD-010 and PSD5V1SD-420: 1. Move the two locking clips outwards as shown in the diagram below (lever with a screwdriver or similar tool) 2. Mount the device on the Panel 3.
  • Page 10 Page 10 – Bulletin 100-50-13.1 The PSD5V1SD-010 and PSD5V1SD-420 are designed as an IP20 product and are to be installed only in type-approved cabinets and/or in points that block access to unauthorized persons. When installing the device, comply with these distances: •...
  • Page 11: Wiring

    Bulletin 100-50-13.1 – Page 11 4. WIRING The following table presents acceptable cable types and wire sizes for wiring to the PSD5V1SD-010 and PSD5V1SD-420 screw terminals. ² 0.2 - 2.5 0.2 - 2.5 0.2 - 2.5 0.2 - 2.5 2 x 0.2 - 1 2 x 0.2 - 1.5 2 x 0.25 - 1 2 x 0.5 - 1.5...
  • Page 12: Wiring Diagrams

    Page 12 – Bulletin 100-50-13.1 WIRING DIAGRAMS NOTICE INOPERABLE DEVICE Verify all wiring connections before applying power. DO NOT Apply voltage or make connection to NC terminals Failure to follow these instructions can result in equipment damage. PSD5V1SD-010 / PSD5V1SD-420 LABEL TERMINAL DESCRIPTION...
  • Page 13 Bulletin 100-50-13.1 – Page 13 Valve Reference document PARKER/SPORLAN Models GC /FGB Bulletin 100-80 – – – 10 11 PSD5 16 17 18 19 Close Valve VALVE CONTROL INPUT – PSD5V1SD-010 – Control Voltage Input Connection PSD5V1SD-420 – Control Current Input Connection –...
  • Page 14: Environmental Characteristics

    Page 14 – Bulletin 100-50-13.1 5. ENVIRONMENTAL CHARACTERISTICS The PSD5V1SD-010 and PSD5V1SD-420 are IP20 rated. They must be installed in a NEMA 1 cabinet or other location protected from exposure to liquids and involuntary contact with high voltages. Use metal cabinets to improve the immunity of the PSD5V1SD-010 and PSD5V1SD-420 to electromagnetic fields.
  • Page 15: Mechanical Characteristics

    Bulletin 100-50-13.1 – Page 15 7. MECHANICAL CHARACTERISTICS 45.3 3.43 1.78 3.43 48.8 70.2 1.92 2.76 61.6 2.43 INPUT / OUTPUT CHARACTERISTICS DESCRIPTION NOTES PSD5V1SD-010: 0 -10V Impedance: 21K Ω, 11Vdc Max. Analog input PSD5V1SD-420: 4 - 20mA Impedance: 100 Ω, 30mA Max. Voltage-free (Dry Contact) Digital input Closure current to ground: 0.5 mA Typ.
  • Page 16: User Interface

    < 4 larm nalog nPut larm © 2024 Parker Hannifin Corporation. Bulletin 100-50-13.1 Parker Hannifin Corporation Sporlan Division 206 Lange Drive, Washington, MO 63090 USA phone 636 239 1111 636 239 9130 www.sporlan.com...

This manual is also suitable for:

Sporlan psd5v1sd-010Sporlan psd5v1sd-420952581952583

Table of Contents