Parker 8903/FA Technical Manual
Parker 8903/FA Technical Manual

Parker 8903/FA Technical Manual

Firewire ieee 1394a communications option

Advertisement

Quick Links

8903/FA
FireWire IEEE 1394a
Communications Option
Technical Manual
HA469265U001 Issue 5
© Copyright 2010 Parker Hannifin Ltd.
All rights strictly reserved. No part of this document may be stored in a retrieval system, or transmitted in any
form or by any means to persons not employed by a Parker Hannifin Ltd., Automation Group, SSD Drives
Europe without written permission from Parker Hannifin Ltd., Automation Group, SSD Drives Europe. Although
every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to
make amendments or correct omissions. Parker Hannifin ltd., Automation Group, SSD Drives Europe cannot
accept responsibility for damage, injury, or expenses resulting there from.
Parker Hannifin Ltd., Automation Group, SSD Drives Europe, warrants the goods against defects in design, materials
and workmanship for the period of 24 months from the date of manufacture, or 12 months from the date of delivery
(whichever is the longer period) on the terms detailed in Parker SSD Drives Standard Conditions of Sale IA500504.
Parker Hannifin Ltd., Automation Group, SSD Drives Europe reserves the right to change the content and product
WARRANTY
specification without notice.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8903/FA and is the answer not in the manual?

Questions and answers

Summary of Contents for Parker 8903/FA

  • Page 1 All rights strictly reserved. No part of this document may be stored in a retrieval system, or transmitted in any form or by any means to persons not employed by a Parker Hannifin Ltd., Automation Group, SSD Drives Europe without written permission from Parker Hannifin Ltd., Automation Group, SSD Drives Europe. Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make amendments or correct omissions.
  • Page 2 Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized...
  • Page 3 Safety Information Requirements IMPORTANT: Please read this information BEFORE installing the equipment. Intended Users This manual is to be made available to all persons who are required to install, configure or service equipment described herein, or any other associated operation. The information given is intended to highlight safety issues, EMC considerations, and to enable the user to obtain maximum benefit from the equipment.
  • Page 4 Safety Information Hazards DANGER! - Ignoring the following may result in injury 1. This equipment can endanger life by exposure to 5. For measurements use only a meter to IEC 61010 rotating machinery and high voltages. (CAT III or higher). Always begin using the highest range.
  • Page 5: Table Of Contents

    Contents Contents Page OMMUNICATIONS PTION Introduction ..................... 1 Product Features ......................1 Product Order Code....................1 Compatible Firmware....................1 Restrictions......................... 1 Installation....................... 2 Wiring the System.................... 5 Terminology ......................5 Powering the Node ....................5 Connecting the Nodes....................5 Extenders........................6 Initial Set-up ....................
  • Page 7: Fire Wire Communications Option

    POWER INPUT CONNECTOR FIREWIRE PORT 0 FIREWIRE PORT 1 FIREWIRE PORT 2 Figure 1. Front of the 8903/FA FireWire Communications Interface Option (Option) Product Order Code Not fitted order code: 8903-FA-00 Factory fitted order code: 890xx-xxxxxxxx-xxx-xxxxA Compatible Firmware This option will work with all versions of 890 firmware.
  • Page 8: Installation

    Option. Legacy 890 drive without the STO feature Figure 3. Front of 890 drive showing Control Board fitted Figure 2. 890 showing Control Board withdrawn with Options fitted 8903/FA Firewire IEEE 1394a Communications Interface...
  • Page 9 2. Press the assembly into the BOTTOM connector (adjacent to terminals X13, X14 and X15) on the Control Board. Ensure that the front panel of the Option overlaps the front of the Control Board. Figure 4. Fitting the connector to the Option 8903/FA Firewire IEEE 1394a Communications Interface...
  • Page 10 2. Tighten in position using the top and bottom screws in the handles of the Control Board. 3. Screw the Option in position using the captive screw on the front of the Option. Figure 5. 890 Control Board with FireWire Communications Option fitted 8903/FA Firewire IEEE 1394a Communications Interface...
  • Page 11: Wiring The System

    72m. 10m cables should be used sparingly, and short (1m) CM469189U010 cables should be used wherever possible CM469189U045 4.5m to ensure this limit is not exceeded. See CM469189U100 "Extenders" below. 8903/FA Firewire IEEE 1394a Communications Interface...
  • Page 12: Extenders

    Any 2 of the above can be used with a CAT5 crossover cable of up to 100m. www.newnex.com … FireNex-MX (TM) 2xIEEE1394a ports, 1x optical duplex LC port Two of the above can be used with 100m of LC to LC ,62.5125um, multi-mode optical cable. 8903/FA Firewire IEEE 1394a Communications Interface...
  • Page 13 Figure 6. Example 4 Rack, 47 Drive Network 8903/FA Firewire IEEE 1394a Communications Interface...
  • Page 14: Initial Set-Up

    Range: —. Time delay between this node and the node hosting the Cycle Time Master. The DSE Configuration Tool is Parker SSD Drives’ Windows-based block programming software and is supplied with each 890 drive. 8903/FA Firewire IEEE 1394a Communications Interface...
  • Page 15: Status Led Indications

    Do not dispose of in a land fill site set aside for domestic waste. Packaging During transport our products are protected by suitable packaging. This is entirely environmentally compatible and should be taken for central disposal as secondary raw material. 8903/FA Firewire IEEE 1394a Communications Interface...
  • Page 16 Page 2 – Replaced photo to show new Safe Torque Off feature. Other minor corrections and amendments. 20814 12 Feb 09 FIRST USED ON MODIFICATION RECORD 8903/FA FireWire Communications Interface DRAWING NUMBER SHT. 1 ZZ469265C001 OF 1 8903/FA Firewire IEEE 1394a Communications Interface...

Table of Contents