Selection of varistor: The nominal operating voltage of the varistor should be
●
selected according to 1.8-2 times the effective value of the SSR's operating
voltage.
Products with an operating current below 5A should be installed near a heat
●
dissipation window with good ventilation, or where is exposed to the cooling wind.
Products with an operating current above 5A should be installed with a heatsink.
●
Thermal conductive silicone grease should be applied between the relay and
the heatsink to enhance heat dissipation. When the surface temperature of the
heatsink approaches 60°C, forced air cooling should be implemented.
In order to prevent the temperature rise of SSRs from exceeding the allowable
●
value, the heat dissipation effect and installation location should be fully
considered during design and application. When installing multiple SSRs side by
side, it is required to leave a suitable distance between them.
Precautions during Maintenance, Service,
8
Transportation and Storage
Check the terminal screws for looseness and inspect the wires for
damage or aging on a regular basis. Check the product that has
been stored or have been out of service for half a year before use.
Warranty Period, Environmental Protection and
9
Other Regulations
9.1 Warranty Period
Provided that the product is stored and transported under normal conditions
and the packaging or product remains intact, the product will be covered by a
warranty period of 36 months from the date of production.
However, the warranty coverage will not apply in the following situations:
Damage caused by improper use, storage and maintenance by the user;
Damage caused by unauthorized disassembly and repair carried out by an
organization or person not designated by the manufacturer, or by the user;
Expiration of the warranty period;
Damage caused by force majeure.
09
Need help?
Do you have a question about the NJG2 and is the answer not in the manual?