P41000 AG Supplemental Directives READ AND SAVE THIS DOCUMENT FOR FUTURE REFERENCE. BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT, PLEASE ENSURE A COMPLETE UNDERSTANDING OF THE INSTRUC- TIONS AND RISKS DESCRIBED HEREIN. ALWAYS OBSERVE ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS IN THIS DOCUMENT COULD RESULT IN SERIOUS INJURY AND/OR PROPERTY DAMAGE.
This document contains important instructions for the use of the product. Always follow all instructions and operate the product with caution. If you have any questions, please contact Knick Elektronische Messgeräte GmbH & Co. KG (sometimes hereafter referred to as “Knick”) using the information provided on the back page of this document.
• Test Report 2.2 according to EN 10204 • Installation Guide with safety instructions Note: The User Manual (this document) is published in electronic form. knick.de ➜ 2.2 Product Identification The different versions of the P41000 AG are encoded in a model designation.
P41000 AG 2.3 Nameplates The P41000 AG is identified by nameplates on the side and front of its housing. The information on the nameplates varies depending on the version of the product. Product Identification, p. 5 ➜ Additional Input Ratings (UL 347): Input Input Rated...
CE marking. UK Conformity Assessed: Conformity mark for the United Kingdom (England, Scotland, and Wales) UL Certification Mark The symbol on Knick products means that the waste devices must be disposed of separately from unsorted municipal waste. 2.5 Function 2.5.1 Functional Description The P41000 AG is available in different versions for unipolar and bipolar input ranges.
Page 8
P41000 AG Hysteresis When traversing the transmission curve, the gain switches with a delay (hysteresis). Transmission Curves, p. 9 ➜ The following figure shows the hysteresis between the upper and lower setpoints as an example of the bipolar transmission curve. 23,2 22,4 21,6...
P41000 AG 2.5.3 Application Example Note: The figure shows an example of current measurement via a shunt resistor. The specified values refer to the version P41100D1‑AG03 with a mounted insertable jumper in terminals 5 and 6. Note: In the figure, Control is used as an umbrella term for any form of further processing of the output signal.
P41000 AG 2.7 Installation and Commissioning WARNING! Shock potential. Do not install the product live. NOTICE! Product damage due to electrostatic discharge (ESD). Take protective measures against electrostatic discharge. NOTICE! Damage to the screw terminals due to excessive tightening torque. Tighten the screw terminals with a max.
Input not connected Establish the connection to the shunt overdriven. or connection to shunt resistor resistor. interrupted. Further troubleshooting support can be obtained from support@knick.de. ➜ See also Terminal Assignments, p. 10 ➜ Installation and Commissioning, p. 11 ➜...
Details on the return and environmentally friendly disposal of electrical and electronic equipment can be found in the manufacturer’s declaration on our website. If you have any queries, suggestions, or questions regarding the recycling of waste electrical and electronic equipment from Knick, please send an email to support@knick.de...
22 … 230 V DC, ± 10 %, approx. 1.2 W Versions with 10 mV available on request ➜ info@knick.de Common-mode rejection ratio = differential voltage gain / common-mode voltage gain Reference temperature for temperature coefficient specifications = 23 °C (73.4 °F) The average temperature coeffi- cient is stated.
P41000 AG Isolation Galvanic isolation 3-port isolation between input, output, and power supply Type test voltage Input against output/power supply P4100*D1‑AG0* 10 kV AC, 1 min P4110*D1‑AG0* 15 kV AC, 1 min Across output and power supply 4 kV AC, 1 min Routine test voltage Dependent on the version Product Identification, p.
Page 17
P41000 AG Device Ambient temperature Operating −10 … 70 °C (14 … 158 °F) Transport and storage −40 … 85 °C (-40 … 185 °F) Ambient conditions Indoor use Relative humidity 5 … 95 %, no condensation Altitude up to 2000 m (6500 ft), air pressure: 790 … 1060 hPa Design Modular housing with screw terminals (max. tightening torque 0.8 Nm) Housing width P41000 AG 22.5 mm...
P41000 AG Abbreviations Adaptive gain Basic impulse level (rated insulation voltage according to UL 347) Conformité Européenne (European conformity) Electromagnetic compatibility European standard Electrostatic discharge International Protection / Ingress Protection Overvoltage category Pollution degree UKCA United Kingdom Conformity Assessed Underwriters Laboratories (recognized testing and certification organization) WEEE Waste from electrical and electronic equipment...
P41000 AG Technical Terms Adaptive Gain Change in gain at a defined setpoint. CE Marking Manufacturer’s declaration, in accordance with EU Regulation 765/2008, that the product is in conformity with the applicable requirements set out in the European Union harmonization legislation providing for its affixing. Hazard A hazard is defined as a potential source of damage.
P41000 AG Index 35 mm DIN rail Open circuit detection, see shunt monitoring Operating ranges Adaptive gain Order code Ambient temperature Output Application example Approvals Package contents Personnel Base latch Personnel requirements Break point Power supply Product code Property damage Causes, malfunctions Conformity Qualified personnel Dimension drawing...
Page 22
Knick Elektronische Messgeräte GmbH & Co. KG Headquarters Beuckestraße 22 • 14163 Berlin Germany Phone: +49 30 80191-0 Fax: +49 30 80191-200 info@knick.de www.knick.de Local Contacts www.knick-international.com Translation of the original instructions Copyright 2023 • Subject to change Version 2 • This document was published on June 26, 2023.
Need help?
Do you have a question about the VariTrans P41000 AG and is the answer not in the manual?
Questions and answers