Autronica AutroVu AV10 Instructions Manual

Autronica AutroVu AV10 Instructions Manual

Explosion-proof universal display unit
Table of Contents

Advertisement

Quick Links

Instructions
AutroVu Explosion-Proof Universal Display Unit AV10
Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, 2014-07-08
P/N 95-8681-4.2, rev. 9/12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AutroVu AV10 and is the answer not in the manual?

Questions and answers

Summary of Contents for Autronica AutroVu AV10

  • Page 1 Instructions AutroVu Explosion-Proof Universal Display Unit AV10 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, 2014-07-08 P/N 95-8681-4.2, rev. 9/12...
  • Page 2 This publication, or parts thereof, may not be reproduced in any form, by any method, for any purpose. Autronica Fire and Security AS and its subsidiaries assume no responsibility for any errors that may appear in the publi- cation, or for damages arising from the information in it.
  • Page 3: Table Of Contents

    Live Maintenance . . . . . . . . . . . . . . . . . . . . . . .G-2 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS...
  • Page 4 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security...
  • Page 5: Application

    4-20 mA output with HART, relay contacts, and MODBUS RS485 (FOUNDATION™ Fieldbus option available). The AV10 Universal Display Unit is designed for use with Autronica gas detectors listed in Table 1. DESCRIPTION The display unit is designed and approved as a ‘stand alone’...
  • Page 6 *Does not support O , but includes C7064C and C7064E hydrogen sulfide, C7067E chlorine, C7066E carbon monoxide, and C7068E sulfur dioxide. Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Page 2...
  • Page 7: Hart Communication

    These switches are used for device configuration, checking status magnets. NOTE Autronica offers two magnet options for activating internal magnetic switches. While the two PREVIOUS magnets can usually be used interchangeably,...
  • Page 8: Relays

    PIR9400 or HC200 where multiple current levels below 4 mA are used for fault diagnostic purposes. Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Page 4...
  • Page 9: Logging

    Unused conduit entries must be closed with CONTROL suitably certified blanking elements upon SYSTEM HART installation. PLC/DCS HART Handheld HART Handheld Figure 3—AV10 Logging Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Page 5...
  • Page 10: Installation

    Horizontal (Fixed to a vertical post) Vertical with Sensor Pointing Down C706X Vertical with Sensor Pointing Down NTMOS Vertical with Sensor Pointing Down Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Page 6...
  • Page 11: Wiring

    Note that the pin identification for the J2 connector is different for each communication protocol. For Foundation Fieldbus it is “– +”. For RS485/MODBUS it is “B A com”. Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Page 7...
  • Page 12: Wiring Procedure

    Figure 4—Position of Jumper P12 for Figure 5—Position of Jumper P12 for Isolated 4-20 mA Loop Output Non-Isolated 4-20 mA Loop Output Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Page 8...
  • Page 13 JUMPERS P3, P5, P7, AND P9 MUST BE POSITIONED AS SHOWN FOR MODBUS/RS485 COMMUNICATION B2528 Figure 7—MODBUS Communication Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Page 9...
  • Page 14 HART communication. Figure 9—AV10 Wired to PLC using 3-Wire Shielded Cable with 4-20 mA Non-Isolated Sourcing Output Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Page 10...
  • Page 15 Isolated operation is highly recommended to prevent noise or ripple on the main power source from interfering with the HART function. Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Page 11...
  • Page 16: Startup

    Gas Detector, it will not be recognized by the AV10 Display until the mode is changed to HART. Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Page 12...
  • Page 17 ENTER to accept the new zero trim value. Select Gain Trim. Follow the same procedure for gain/span calibration. Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Page 13...
  • Page 18 Self Test Display Setup Response Test Device Setup Loop Test Device Cal D/A Trim Display Test Device Test Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Page 14...
  • Page 19: Password Protection

    The default password is 1*******. IMPORTANT Take care not to lose the password. Future changes cannot be made without a password. Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Page 15...
  • Page 20: Troubleshooting

    Note: A fault condition will cause an oxygen detector to generate an alarm output as the decreasing 4-20 mA signal passes through the alarm range. Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Page 16...
  • Page 21 . Start Cal Fault Calibration fault Verify correct sensor type and calibrate . *HC600 only . Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Page 17...
  • Page 22 Return to factory . 5V Fault 5 volt internal power supply out of tolerance Return to factory . Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Page 18...
  • Page 23: Specifications

    NOTE –55°C to +75°C. Appropriate relays will be activated when a fault or alarm occurs. HUMIDITY RANGE— 5 to 95% RH (Autronica verified). CURRENT OUTPUT— Linear isolated 4-20 mA output with HART. ELECTRO-MAGNETIC COMPATIBILITY— 3.8 mA indicates calibrate mode. EMC Directive 2004/108/EC 3.6 mA or less indicates a fault condition.
  • Page 24: Warranty

    12 months from date of installation or 18 months from date of shipment, whichever occurs first. ENCLOSURE MATERIAL— Epoxy coated aluminum or 316 stainless steel. DETECTOR COMPATIBILITY— The AV10 can be used with the Autronica gas detectors listed in Table 5. SHIPPING WEIGHT— Aluminum: 4.15 pounds (1.88 kilograms).
  • Page 25 2 Methane, Ethane, Ethylene, Propane, and Propylene . 3 C7065E Oxygen detector is not supported . 4 Hydrogen sulfide only. Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Page 21...
  • Page 26: Device Repair And Return

    DEVICE REPAIR AND RETURN ORDERING INFORMATION Prior to returning devices, contact the nearest local Autronica Fire Sensor module, transmitter module and termination boxes (if used) and Security office so that a Return Material Identification (RMI) must be ordered separately. number can be assigned. A written statement describing Refer to the AV10 Model Matrix for ordering details.
  • Page 27 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 28: Appendix A - Fm Approval Description

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 29: Appendix B - Csa Certification Description

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 30: Appendix C - Atex Approval Description

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 31: Appendix D - Iecex Approval Description

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 32: Appendix E - Additional Approvals

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 33: Appendix F - Av10 With Handheld Hart Communicator

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 34 8) DD Build Version 3) Reset 3) Other Calibration Log 4) Loop Test 4) End -------------------------------------------------- 5) D/A Trim Calibration Log CalCode: xx Timestamp: xxxxxxxxx Autronica Fire and Security Device History Info ----------------------------------------------- 1) Calibration Log First Previous HART Next 20-Feb-13 4.21...
  • Page 35: Appendix G - Av10 With Gt3000 Toxic Gas Detector

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 36: Orientation

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 37: Calibration

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 38: Menu Structure

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 39 WRITE PROTECT 6 MA LOOP TEST 8 MA CHANGE STATE 10 MA DEVICE TEST CHANGE PASSWORD EVENT LOG SET 4-20 MA Autronica Fire and Security 12 MA WRITE PROTECT XXXX 14 MA SELF TEST EVENT XXXXX 16 MA RESPONSE TEST...
  • Page 40: Appendix H - Av10 With Pir9400

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 41: Installation Notes

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 42: Changing Operating Modes

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 43: Menu Structure

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 44 XXXXX LOOP TEST D/A TRIM 20 MA OUTPUT READBACK XX.XX MA D/A TRIM WRITE PROTECT ANALOG INPUT XX.XX MA ZERO TRIM GAIN TRIM CHANGE STATE CHANGE PASSWORD WRITE PROTECT XXXX Autronica Fire and Security OP FEEDBACK FLT PIR9400 20-Feb-13 4.21...
  • Page 45: Appendix I - Av10 With Autropoint Hc200

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 46: Orientation

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 47: Calibration

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 48: Menu Structure

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 49 SET 4-20 MA DEVICE TEST 4 MA SET 4-20 MA 12 MA 6 MA 14 MA SELF TEST 8 MA Autronica Fire and Security 16 MA 10 MA RESPONSE TEST 18 MA D/A TRIM LOOP TEST 12 MA D/A TRIM...
  • Page 50: Appendix J - Av10 With Autropath Hc600 Open Path Gas Detector

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 51 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 52: Orientation

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 53: Hc600 Transmitter Lamp Fault Condition

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 54 XX.XX MA GAIN TRIM 3.5MA EVENT LOG 4 MA 6 MA EVENT XXXXX OP FEEDBACK FLT LOOP TEST Autronica Fire and Security 8 MA DTIME MM/DD-HH:MM DEVICE TEST 10 MA SET 4-20 MA 12 MA SELF TEST 14 MA RESPONSE TEST...
  • Page 55: Appendix K - Av10 With Ntmos H2S Sensor

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 56 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 57 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 58: Orientation

    The NTMOS detector must be calibrated using 50 ppm H S in air (never use H S in nitrogen). Autronica provides two acceptable sources of 50 ppm H AUTROVU AV10 calibration gas for use with NTMOS detectors. WARNING NTMOS H2S SENSOR...
  • Page 59: Menu Structure

    AV10 mA Output During Calibration (AV10 with NTMOS) Calibration Procedure Standard Replicate AV10 Display Reading To calibrate the NTMOS detector with the AutroVu AV10 Display: Mode Mode Waiting for Zero 3 .8 2 .2 1. Touch the magnet to the ENTER/SELECT button to display the Main Menu.
  • Page 60 XX.XX MA SELF TEST 14 MA RESPONSE TEST 16 MA CHANGE STATE LOOP TEST 18 MA D/A TRIM CHANGE PASSWORD Autronica Fire and Security 20 MA D/A TRIM WRITE PROTECT XXXX ZERO TRIM GAIN TRIM OP FEEDBACK FLT NTMOS 20-Feb-13...
  • Page 61: Appendix L - Av10 With C706X Toxic Gas Sensor

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 62 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 63: Installation

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 64: Calibration

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 65 SET 4-20 MA 12 MA CHANGE PASSWORD SELF TEST 14 MA WRITE PROTECT XXXX RESPONSE TEST 16 MA Autronica Fire and Security D/A TRIM LOOP TEST 18 MA D/A TRIM 20 MA ZERO TRIM OP FEEDBACK FLT GAIN TRIM C706X 20-Feb-13 4.21...
  • Page 66: Appendix M - Av10 With Model Cgs Combustible Gas Sensor

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 67 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 68: Installation

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 69: K Factor

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 70 HART ERRORS XXXXX 16 MA RESPONSE TEST MODBUS ERRORS XXXXX 18 MA LOOP TEST D/A TRIM OP FEEDBACK FLT OUTPUT READBACK XX.XX MA 20 MA D/A TRIM ANALOG INPUT XX.XX MA ZERO TRIM GAIN TRIM Autronica Fire and Security 20-Feb-13 4.21...
  • Page 71: Appendix N - Av10 With Generic 4-20 Ma Sensors

    Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Instructions, AutroVu Explosion-Proof Universal Display Unit AV10, 116-P-AV10/IGB, rev. E, P/N 95-8681-4.2, rev. 9/12, 2014-07-08 Autronica Fire and Security AS Autronica Fire and Security AS...
  • Page 72 ZERO TRIM GAIN TRIM DEBUG MENU HART ERRORS XXXXX AUTOMATIC MODBUS ERRORS XXXXX OUTPUT READBACK XX.XX MA ANALOG INPUT XX.XX MA WRITE PROTECT CHANGE STATE CHANGE PASSWORD WRITE PROTECT XXXX Autronica Fire and Security OP FEEDBACK FLT GENERIC 20-Feb-13 4.21...
  • Page 74 Autronica Fire and Security AS Haakon VIIs gt. 4, NO-7041 Trondheim, Norway | Tel: +47 90 90 55 00 | Fax: +47 73 58 25 01 E-mail: info@autronicafire.no | www.autronicafire.com...

Table of Contents