Summary of Contents for SEELEY INTERNATIONAL Braemar XK46
Page 1
OWNER’S MANUAL VRF MULTI SPLIT CONTROLLER XK46 SLEEP MODE ENTER/CANCEL FUNCTION TIMER SWING ON/OFF SEELEY INTERNATIONAL - OWNER’S MANUAL...
Page 2
IMPORTANT As with any product that has moving parts or is subject to wear and tear, it is VERY IMPORTANT that you maintain your air conditioner and have it regularly serviced. Accordingly, it is a condition of warranty cover for your air conditioner that you comply with all of the maintenance and service requirements set out in this manual.
INTRODUCTION AND SAFETY Congratulations on purchasing a new Braemar Air Conditioner! Please keep this Manual and the Warranty Booklet in a safe place, along with the original purchase documents, plus all relevant certificates of compliance relating to the installation work performed. Please register the Warranty straight away, by following the steps set out in the Warranty Booklet.
Page 5
Children should be supervised to ensure that they do not play with the appliance. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. SEELEY INTERNATIONAL - OWNER’S MANUAL...
CONTROLLER LAYOUT Your Braemar Air Conditioner has been designed and built with reliable, quality components. To ensure many years of trouble free, dependable service please read the following pages very carefully, and please ensure that you follow all of the instructions. WIRED CONTROLLER Please follow the below cautionary notes when using the wired controller:- 1.
Page 7
When inquiring or setting project number of indoor unit, it displays ”NO.” icon Floor Heating mode (When Heating and Floor Heating simultaneously shows up, it indicates 3D Heating is activated.) Table 01: Description of symbols SEELEY INTERNATIONAL - OWNER’S MANUAL...
Page 8
Symbol Instructions Display “SET” icon under parameter setting interface Space Heating mode Display “CHECK” icon under parameter view interface Outdoor unit operates under Save mode / upper limit of system capacitor less 100% / remote Save status Sleep status Current set fan speed (including auto, low speed,medium-low speed, medium speed,medium-high speed, high speed and turbo seven status) Airstatus, Indoor unit optional function Remind to clean the filter...
Page 9
Invalid operation Current wired controller connects primary indoor unit Timer zone : Display system clock and timer status *Note: When wired controller is connected with different indoor units, some functions will be different. SEELEY INTERNATIONAL - OWNER’S MANUAL...
Page 10
BUTTON GRAPHICS Fig. 02 Buttons Instructions ENTER/CANCEL Select and cancel function (1) Set operating temperature of indoor unit (2) Set timer (3) Switch Quiet mode, Air grade, Clean grade, set upper and lower temperature limit under Save mode (4) Set and inquiry parameter SLEEP Set Sleep mode Switch among auto, low speed, low-medium speed, medium speed,...
INSTALLATION Fig. 03 Name Panel of wired controller Self-tapping Screw ST3.9X25 MA Mount plate of wired controller Q’ty SEELEY INTERNATIONAL - OWNER’S MANUAL...
INSTALLATION cont. WIRING REQUIREMENTS Fig. 04.1 Fig. 04.2 (1) When one wired controller controls multiple indoor units simultaneously, the wired controller can connect to any one indoor unit, but the connected indoor unit must be the same series indoor unit. The total quantity of indoor unit controlled by wired controller can’t exceed 16 sets, and the connected indoor unit must be within the same indoor unit’s network.
Page 13
Series of indoor units include:Common Multi VRF Units;Fresh Air Units; Double-heat Sources Units;Combined Units; Except for fresh air units, double-heat sources units and combined units, the rest of indoor units belong to common multi VRF units. Fig. 04.4 SEELEY INTERNATIONAL - OWNER’S MANUAL...
Page 14
INSTALLATION cont. COMMUNICATION LINE SELECTION Indoor Unit 1 Indoor Unit 2 Indoor Unit 3 Indoor Unit n L(n-1) L=L01+L02+L1+L2+..L(n-1)(n<16) Secondary Primary Wired Controller Wired Controller Fig. 05 Total length of communication line Wire size Material Wire material type between indoor unit Remarks /AWG) standard...
(5) Set two-core into the groove at left side of wiring column, and then bundle panel and mount plate of wired controller together. Note: If the wire size of the selected communication line is too large, you can peel some sheath layer of communication wire to satisfy installation requirements. SEELEY INTERNATIONAL - OWNER’S MANUAL...
Disassembly Fig. 07 COMMISSIONING Set Primary Indoor Unit Under Off status, long press MODE button for 5s to set the corresponding indoor unit of wired controller as primary indoor unit. “PRIMARY” icon will be light after finishing setting. Note: There is a primary indoor unit in a system, other secondary indoor units can be set as primary unit, in which case, the original primary unit will become a secondary unit.
Page 17
Press “ ” or “ ” button to select indoor unit. operation 01: priority Display method: operation Temperature zone: displays current indoor unit project number; Timer zone: displays current priority operation setting value of indoor unit. SEELEY INTERNATIONAL - OWNER’S MANUAL...
Page 18
Parameter Parameter name Parameter Viewing method code range Operation method: Enter viewing: press MODE button in “C07” status to enter the interface of viewing indoor ambient temperature. View indoor Press “ ” or “ ” button to select indoor unit. ambient temperature Display method:...
Page 19
Fresh Air Indoor Display method: Unit* Temperature zone: displays current indoor unit project number Timer zone: displays air outlet temperature of Fresh Air Indoor Unit Note: only applicable to Fresh Air Indoor Unit. SEELEY INTERNATIONAL - OWNER’S MANUAL...
Page 20
PARAMETER SETTINGS Unit parameters can be set in unit On or Off status. (1) Long press FUNCTION button for 5s and the temperature zone displays “C00”; long press FUNCTION button for another 5s to enter the interface of setting wired controller parameters. “P00” is displayed in temperature zone;...
Page 21
When the temperature unit is°C, cooling setting under auto temperature minus heating setting temperature 1°C. mode Heating When the temperature unit is°F, cooling setting setting temperature minus heating setting temperature°F 2ºF 16ºC~29ºC 20°C temp (61ºF~84ºF) (68°F) under auto mode SEELEY INTERNATIONAL - OWNER’S MANUAL...
Page 22
Parameter Parameter Parameter range Viewing Note code name method 00: normal When power supply is insufficient, the indoor units Set priority operation which are set to priority operation can operate, while operation 01: priority other indoor units are forced to be turned off. operation Clear Filter Clean...
The appliance will operate according to the preset sleep curve to provide a comfortable sleep environment. AIR EXCHANGE SETTING Adjusts the amount of indoor fresh air to improve air quality and keep indoor air fresh. SEELEY INTERNATIONAL - OWNER’S MANUAL...
Page 24
OPERATION cont. LIGHT ON/OFF SETTING Backlight of controller can be turned on or off. SAVE FUNCTION SETTING Air conditioner can be operated in small temperature range by setting the minimum temperature under Cooling and Dry modes and setting maximum temperature under Heating, 3D Heating and Space Heating modes.
Under Auto mode, if the indoor unit is running under Cooling, the icons “ ” and “ ” will light up; if the indoor unit is running under Heating, the icons“ ” and“ ”will light up. SEELEY INTERNATIONAL - OWNER’S MANUAL...
OPERATION cont. TEMPERATURE SETTING Press button to increase or decrease setting temperature when the unit is on. Pressing either “ ” or “ ” of them continuously, will increase or decrease by 1°C or 1°F every 0.3s. In Cooling, Dry, Fan and Heating mode, temperature setting range is 16°C~30°C or 61°F~86°F. In Dry mode, the temperature setting range is 12°C or 54°...
Press the FAN button to vary the speeds as shown in the sequence below: SLEEP SLEEP MODE MODE ENTER/CANCEL ENTER/CANCEL FUNCTION TIMER SWING ON/OFF FUNCTION TIMER SWING ON/OFF Press FAN button to adjust the Press FAN button again to increase fan speed. the fan speed. SEELEY INTERNATIONAL - OWNER’S MANUAL...
OPERATION cont. TURBO FUNCTION SETTING Press FUNCTION button to switch to “TURBO” function. The TURBO icon will flash. Press the ENTER/CANCEL to start function. When the “TURBO” function is activated the “TURBO” icon will be displayed. To deactivate the “TURBO” function press the FUNCTION button to switch to “TURBO” function, then press the ENTER/CANCEL button to deactivate.
Press and hold the TIMER button for 5s, the “ ” symbol will blink. Press the buttons to “ ” or “ ” adjust the clock time. Press ENTER/CANCEL button to save the setting and exit. SEELEY INTERNATIONAL - OWNER’S MANUAL...
Page 30
OPERATION cont. CLOCK TIMER The clock timer can be set for 3 modes: Unit ON, Unit OFF and Unit ON/OFF. Press TIMER button to enter Timer function, the ON symbol will blink. Press buttons to adjust “ ” or “ ” the ON time.
Cancel left & right swing: When left & right swing is activated, press “FUNCTION” button to switch to left & right swing with left & right swing icon “ ” blinking, and then press “ENTER/CANCEL” button to cancel left & right swing. SEELEY INTERNATIONAL - OWNER’S MANUAL...
OPERATION cont. QUIET SETTING Press the FUNCTION button to select Quiet or AutoQuiet function. The QUIET “ ” or AutoQuiet “ ” icon will flash. Press ENTER/CANCEL button to activate. When the “QUIET” function is activated, press the FUNCTION button to select “QUIET ” icon, press ENTER/CANCEL button to deactivate “QUIET”...
ENTER/CANCEL MODE ENTER/CANCEL ENTER/CANCEL FUNCTION TIMER SWING ON/OFF FUNCTION TIMER SWING ON/OFF FUNCTION TIMER SWING ON/OFF Unit On, no SLEEP Press SLEEP button to Press SLEEP button to activate SLEEP function deactivate SLEEP function function SEELEY INTERNATIONAL - OWNER’S MANUAL...
OPERATION cont. AIR EXCHANGE SETTING When the unit is ON, press the FUNCTION button to select “AIR” function, the “AIR” function icon will flash, press to adjust the “AIR” type. Press the ENTER/CANCEL button to activate. “ ” or “ ” Setting 1-9: The unit runs continuously for 60 minutes, fresh air valve runs for 6 minutes (setting 1) to 54 minutes (setting 9), in 6 minute increments.
When there is no button operation on the wired controller or no remote control signal is received for 20s continuously: • If Light function is activated, the back light of LCD will turn to half bright. • If Light function is off, the back light of LCD will be off. SEELEY INTERNATIONAL - OWNER’S MANUAL...
OPERATION cont. SAVE FUNCTION SETTING The SAVE setting will make the air conditioner operate in a smaller temperature range by limiting the lower temperature value in the COOL or DRY mode and upper value in HEAT mode. There’re two kinds of setting method for Save function.
Page 37
SAVE inOFF status SLEEP MODE SLEEP ENTER/CANCEL MODE ENTER/CANCEL FUNCTION TIMER SWING ON/OFF FUNCTION TIMER SWING ON/OFF Press ENTER/CANCEL button to activate SAVE function. Press “ ” or “ ” button to adjust the minimum temperature. SEELEY INTERNATIONAL - OWNER’S MANUAL...
Page 38
OPERATION cont. Setting method two: Energy Saving Setting for Cooling: When the unit runs under the COOL or DRY mode, press the FUNCTION button to select the “SAVE” function. While “SAVE” icon is flashing and “MIN” icon is lit up, press “...
ON/OFF FUNCTION TIMER SWING ON/OFF FUNCTION TIMER SWING ON/OFF Press FUNCTION button or “ Press “ ” ” ” “ Press ENTER/CANCEL to set FILTER function button to set desired level to activate FILTER function SEELEY INTERNATIONAL - OWNER’S MANUAL...
OPERATION cont. Level of Contamination Description of Levels Turn off Clean Timer zone shows 00 The first digit shows 1 while the second one shows 0, each increment of 1 in the second Light number increases operating time by 500 hours. Range: 5500 - 10000 hours. The first digit shows 2 while the second one shows 0, each increment of 1 in the second Medium number increases operating time by 400 hours.
The model cannot be connected to the gate control system on it own. For the gate control system to be activated it must be connected with a wired controller that includes a gate control signal detecting function. SEELEY INTERNATIONAL - OWNER’S MANUAL...
ERROR DISPLAY When an error occurs to the unit, the error code will be shown on the wired controller. When multiple errors simultaneously happens, the error codes will be shown cyclically on the display. When an error occurs, please immediately shut down the unit and contact your Seeley approved service agent.
Sensor Error Under-Ratio Protection Compressor 3 Discharge Mode Exchanger Inlet Pipe Protection of Abnormal Temperature Sensor Error Temperature Sensor Error Pressure Compressor 4 Discharge Protection of Water Flow Malfunction of DC motor Temperature Sensor Error Switch SEELEY INTERNATIONAL - OWNER’S MANUAL...
Page 44
ERROR CODES FOR OUTDOOR UNITS cont. Error Error Error Description Description Description Code Code Code Compressor 2 Top Gas-Liquid Separator outlet Oil return pipe is blocked Temperature Sensor Temperature Sensor Error Detachment Protection Outdoor Humidity Compressor Drive Board Oil return pipe is leaking Sensor Error Error Protection of Low...
Outlet Pipe Temperature Indoor Air Box Sensor Incompatibility Error Sensor Error Error Inconsistency of Outdoor Air Box Sensor Humidity Sensor Error Group-controlled Indoor Units in Error Reheat Dehumidification System Outdoor-Indoor Water Temperature Incompatibility Error Abnormality SEELEY INTERNATIONAL - OWNER’S MANUAL...
DEBUGGING CODES Error Error Error Description Description Description Code Code Code Outdoor Unit Capacity Emergency Operation DIP Communication Failure Code/Jumper Cap switch setting of the Between Mode Exchanger Setting Error compressor is wrong. and Indoor Unit. Communication between indoor unit and outdoor unit and the Phase Sequence Error of Multiple communication between indoor...
MAINTENANCE SCHEDULE Please NOTE: The Maintenance Schedule covers Year 1 to Year 5 Installation Date: Installer: Items to be done by the (please sign in the places indicated) Home Owner/User Monthly Annually Year 1 Year 2 Year 3 Year 4 Year 5 Air filter cleaning Air filter replacement Maintain required clearance...
Page 49
To preserve your investment for many years after the expiry of warranty, we strongly recommend that you continue to maintain and service the Braemar Air Conditioner appliance as per the items and frequency set out in the Schedule, and as indicated elsewhere in the Owner’s Manual. SEELEY INTERNATIONAL - OWNER’S MANUAL...
OPERATION TIPS The following events may occur during normal operation: 1. Protection of the air conditioner. Compressor protection -The compressor cannot restart for 3 minutes after it stops. -The supply air drops below a pre-determined set point; this prevents the indoor coil from freezing.
Page 51
3.1 In heating or cooling operation, any 3. ‘Clicking’ sound plastic parts may expand or shrink due is heard from the air 3.1 This is normal. to a sudden temperature change. In this conditioner. event, a clicking sound may occur. SEELEY INTERNATIONAL - OWNER’S MANUAL...
Page 52
Warranty Service Australia 1300 650 644 It is the policy of Seeley International to introduce continuous product improvement. Accordingly, specifications are subject to change without notice. Please consult with your dealer to confirm the specifications of the model selected. XK4602-B...
Need help?
Do you have a question about the Braemar XK46 and is the answer not in the manual?
Questions and answers