IMPORTANT As with any product that has moving parts or is subject to wear and tear, it is that you maintain your air conditioner and have it regularly VERY IMPORTANT serviced. Accordingly, it is a condition of warranty cover for your air conditioner that you comply with all of the maintenance and service requirements set out in this Manual.
INTRODUCTION & SAFETY Congratulations on purchasing a new when the Braemar Air Conditioning Unit Braemar Air Conditioner! is used. Note: the manufacturer recommends that low level return air grilles Please keep this Manual and the are installed. Warranty Booklet in a safe place, along with the original purchase IMPORTANT! documents, plus all relevant...
6. Before operating the air conditioner, please read this manual carefully and keep it in a safe place for future reference. SEELEY INTERNATIONAL – OWNER’S MANUAL...
OPERATION cont. LCD ICONS Display Definition Instruction Displays when the current indoor unit connected by the wired controller is primary indoor unit Primary (the icon will not be displayed when the wired controller connects to heat recovery unit) Displays when one wired controller controls multiple Group control indoor units at the same time It means the current wired controller...
Swing/ control mode of Control air conditioner. Select mode and MENU/OK confirm parameters For use with the Remote wireless wall Receiver controller (optional) ON/OFF/ Turn on/off the unit and Return return to the previous page SEELEY INTERNATIONAL – OWNER’S MANUAL...
OPERATION cont. ON / OFF MODE SETTING Press the On/Off button to turn the Under the ON state of the appliance, appliance On or Off. press the Mode button to switch the operation modes as the sequence shown below. 12:00 11/22/2022 Mon 12:00 11/22/2022 Mon...
11/22/2022 Mon temperature when Cool the appliance is Set Temp Cool Pressing 12:00 11/22/2022 Mon continuously, temperature will Set Temp 12:00 11/22/2022 Mon be increased or Med_low Cool Set Temp decreased by 1°C every 0.3s Cool SEELEY INTERNATIONAL – OWNER’S MANUAL...
OPERATION cont. FUNCTION SETTING Press MENU/OK button on main page to enter main menu page. Press > button to select the function setting symbol. Press the menu Press button to enter cycle between the the menu page. menu options. 12:00 11/22/2022 Mon Function Press...
Page 11
For Dry mode only, set temperature becomes 12°C E-Heater If fitted, can turn on auxiliary ON = OFF = heating coil to aid Dry or Heat modes Selects the highest air speed Turbo ON = OFF = SEELEY INTERNATIONAL – OWNER’S MANUAL...
Page 12
OPERATION cont. FUNCTION SETTING cont. Function Options Extended Menu Comments Level 1 (Open 6 mins every hour) For units with air function and ON = OFF = , > extended menu to 10 (constantly open) fresh air valve installed Save ON = OFF = , >...
Press the < buttons to select the Left / Right swing 12:00 11/22/2022 Mon operation. Set Temp Press the Cool buttons to toggle on or off the swing function. Press OK button to save the setting. SEELEY INTERNATIONAL – OWNER’S MANUAL...
OPERATION cont. FIXED SWING cont. INDEPENDENT SWING LEFT / RIGHT SWING For cassette models only, it is possible to operate the individual Up and Down When selected, louvre sets independently of each other. the appropriate icons will be shown. Function U&D Swing Sleep Lock...
Function Schedule1 Press OK button Schedule2 to enter into menu. Schedule3 Schedule4 Press OK button to enable schedule. Schedule 1 Enable Cool 08 : 30 On 26 C 17 : 30 Off Auto Repeat :No SEELEY INTERNATIONAL – OWNER’S MANUAL...
OPERATION cont. SCHEDULE ON TIME SCHEDULE REPEAT Press Use this function to repeat a button to select schedule. the On time. Schedule 1 Enable Cool Press OK button to Press button 08 : 30 On 26 C enter into the setting to select Repeat and 17 : 30 Off Auto...
IDU Project No. View and Locating locating will display enter menu. IDU1 Project No. View and Locating View ALL IDU Project No. the number of IDU Project No.: 2 indoor units and the Error Code: Null error code. SEELEY INTERNATIONAL – OWNER’S MANUAL...
OPERATION cont. VIEW ALL PROJECT NO. HOTLINE Use this function to view all the Use this function to view or set IDU and project number. the Local Aftersales telephone details. Press Press button to select button to select Hotline tab. view ALL IDU Menu Project View...
Language Date and Time Sound Press OK button Project Set to enter menu. Press OK button to enter menu. Language Press the Return button to return to previous page. English SEELEY INTERNATIONAL – OWNER’S MANUAL...
OPERATION cont. TIME FORMAT SET TIME The time format can be set to either 12 The user can set the set time hour or 24 hour. and date through this function. Press Press button to select buttons to select the time format set time button.
Language Press OK button enter page. Date and Time Date and Time to enter menu. Sound Sound Project Set Project Set Press buttons to select the On or Off. Sound Press OK button to save. SEELEY INTERNATIONAL – OWNER’S MANUAL...
PROJECT SETTINGS Comments Item Settable range Default When it is off, this wired controller is primary Master Wired ON = OFF = wired controller, status column of the Controller homepage displays the icon of primary wired controller , the wired controller can only activate the primary wired controller, it does not have the function of setting parameters for other...
The actual waiting time is related to the outdoor ambient temperature. If there is cold air after turning on the heating mode in the actual operation, please consult the professional person to adjust this parameter. SEELEY INTERNATIONAL – OWNER’S MANUAL...
INSTALLATION ERROR STATUS INSTALLATION INSTRUCTIONS The error status can be viewed on the screen. 12:00 11/22/2022 Mon When an error occurs to the appliance, the error code will be shown on the display When an error occurs, please immediately shut down the unit and contact your Seeley approved service agent.
Oil-return 3 Temperature Sensor Error Compressor 1 Current Sensor Error Water-out Temperature Sensor Error Compressor 6 Current Sensor Error Outdoor Unit Error Compressor 3 Current Sensor Error Mode Exchanger Inlet Pipe High Pressure Protection Temperature Sensor Error SEELEY INTERNATIONAL – OWNER’S MANUAL...
Page 26
Lorem ipsum ERROR CODES FOR OUTDOOR UNITS cont. Error Code Error Description Error Code Error Description Malfunction of DC motor 4-way Valve Blow-by Protection Compressor 2 Top Temperature Sensor System Pressure Over-Ratio Error Protection System Pressure Under-Ratio Water-in Temperature Sensor Error Protection PV DC/DC Protection Protection of Abnormal Pressure...
Error Water Full Protection IDU Losing Step Protection Wired Controller Power Supply Error IDU Driver Communication Error Communication Error of IDU Master Anti-Frosting Protection Controller No Master Indoor Unit Error High Temperature of IDU Module SEELEY INTERNATIONAL – OWNER’S MANUAL...
Page 28
ERROR CODES FOR INDOOR UNITS cont. Error Code Error Description Error Code Error Description Temperature Sensor Error of IDU Outdoor Air Box Sensor Error Module IFD error IDU Charging Circuit Error Inlet Pipe Temperature Sensor 2 Error Air-return Inlet Sensor Error Air-return Outlet Temperature Sensor Outlet Pipe Temperature Sensor 2 Error Error...
Communication Error between Indoor Electronic expansion valve leak error Unit and Remote Receiver of thermal storage module Communication Error of No Master in PV module overheating protection Mode Exchanger Outdoor Unit Capacity Code/Jumper Cap Setting Error SEELEY INTERNATIONAL – OWNER’S MANUAL...
We recommend checking that plants haven't grown into or around the air intake or outlet, along with other debris that may build up over time, namely, leaves and the like. SEELEY INTERNATIONAL – OWNER’S MANUAL...
MAINTENANCE SCHEDULE Installation Date: Installer: Items to be done by the (please sign in the places indicated) Home Owner/User Monthly Annually Year 1 Year 2 Year 3 Year 4 Year 5 Air filter cleaning Air filter replacement Maintain required clearance around Outdoor unit Items to be done by a Qualified Licensed Technician...
60 seconds the indoor fan will stop blowing air. When the room temperature rises back to the set point, the indoor fan and the compressor will start again. SEELEY INTERNATIONAL – OWNER’S MANUAL...
Page 34
NOTE: Air outlet Seeley International strives for continuous product improvements, therefore specifications are subject to change without notice. Unit colour may vary slightly from that depicted in this booklet. Installation and commissioning of this system to the manufacturer's specification, and compliance with industry standards, and local, state and national regulatory codes, are the responsibility of the installer.
Page 36
Warranty Registration (Australia Only) To register your warranty, go to www.seeleyinternational.com Warranty Service Australia: 1300 650 644 New Zealand: 0800 589 151 seeleyinternational.com It is the policy of Seeley International to introduce continual product improvement. the model selected. XE7001-B AU 2403...
Need help?
Do you have a question about the Braemar XE70 and is the answer not in the manual?
Questions and answers