Daikin FTXTM40A2V1B Installation Manual
Hide thumbs Also See for FTXTM40A2V1B:
Table of Contents

Advertisement

Quick Links

Installation manual
Daikin room air conditioner
FTXTM30A2V1B
FTXTM40A2V1B
Installation manual
English
Daikin room air conditioner
ATXTM30A2V1B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FTXTM40A2V1B and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin FTXTM40A2V1B

  • Page 1: Table Of Contents

    Installation manual Daikin room air conditioner FTXTM30A2V1B FTXTM40A2V1B Installation manual English Daikin room air conditioner ATXTM30A2V1B...
  • Page 2: Table Of Contents

    ▪ A subset of the latest technical data is available on the regional 11 Disposal Daikin website (publicly accessible). 12 Technical data ▪ The full set of the latest technical data is available on the Daikin 12.1 Wiring diagram ................11 Business Portal (authentication required).
  • Page 3: About The Box

    ▪ the accessory bag located at the bottom of the package, ▪ the mounting plate attached to the back of the indoor unit, ▪ the spare SSID sticker located on the front grille. FTXTM-A, ATXTM-A Installation manual Daikin room air conditioner 3P769578-1 – 2024.04...
  • Page 4: About The Unit

    INFORMATION: Declaration of conformity ▪ Wall insulation. When conditions in the wall exceed 30°C and a ▪ Daikin Industries Czech Republic s.r.o. declares that relative humidity of 80%, or when fresh air is inducted into the the radio equipment type inside of this unit is in wall, then additional insulation is required (minimum 10 ...
  • Page 5 Pocket for the pipe port cover For ATXTM FTXTM pipe end use marking “L” and “G” (Class 30) Liquid pipe end For FTXTM pipe end use marking “L” and “G” (Class 40) FTXTM-A, ATXTM-A Installation manual Daikin room air conditioner 3P769578-1 – 2024.04...
  • Page 6: To Drill A Wall Hole

    Do NOT use nippers to remove the pipe port cover, as this would damage the front grille. 4 Attach the drain hose to the refrigerant piping bottom side using adhesive vinyl tape. Installation manual FTXTM-A, ATXTM-A Daikin room air conditioner 3P769578-1 – 2024.04...
  • Page 7: To Check For Water Leaks

    (Ø) NOTICE Ø 6.4 mm (1/4") Annealed (O) ≥0.8 mm Make sure to insulate all refrigerant piping. Any exposed 9.5 mm (3/8") Annealed (O) piping might cause condensation. FTXTM-A, ATXTM-A Installation manual Daikin room air conditioner 3P769578-1 – 2024.04...
  • Page 8: To Check Refrigerant Piping Joints For Leaks After Charging Refrigerant

    Note: In case the interconnection cable was stripped in advance, cover the ends with insulating tape. 4 Bend the end of the cable up. Installation manual FTXTM-A, ATXTM-A Daikin room air conditioner 3P769578-1 – 2024.04...
  • Page 9: To Connect Optional Accessories (Wired User Interface, Central User Interface, Etc.)

    Insulation tape Mounting plate (accessory) NOTICE ▪ Do NOT bend refrigerant pipes. ▪ Do NOT push the refrigerant pipes onto the bottom frame or the front grille. FTXTM-A, ATXTM-A Installation manual Daikin room air conditioner 3P769578-1 – 2024.04...
  • Page 10: To Fix The Unit On The Mounting Plate

    Next commissioning instructions in this chapter, a general Prerequisite: Test run may be performed in cooling or heating commissioning checklist is also available on the Daikin mode. Business Portal (authentication required). Prerequisite: Refer to the operation manual of the indoor unit for setting temperature, operation mode….
  • Page 11: To Perform A Test Run Using The Wireless Remote Control

    ▪ A subset of the latest technical data is available on the regional Daikin website (publicly accessible). Light emitting diode (service monitor green) ▪ The full set of the latest technical data is available on the Daikin HIGH VOLTAGE High voltage Business Portal (authentication required).
  • Page 12 Diode bridge, Insulated-gate bipolar transistor (IGBT) power module Wireless remote controller Terminal Terminal strip (block) Electronic expansion valve coil Y*R, Y*S Reversing solenoid valve coil Ferrite core ZF, Z*F Noise filter Installation manual FTXTM-A, ATXTM-A Daikin room air conditioner 3P769578-1 – 2024.04...
  • Page 16 3P769578-1 2024.04...