Advertisement

Unit 4, Kimpton Trade & Business Centre
Minden Road, Sutton, Surrey, SM3 9PF
Tel: 020 8254 6802
USE & MAINTENANCE INSTRUCTIONS
FOR NU-FLAME BLAZE 600 NATURAL GAS FIRE
a. This fire must be installed by a properly qualified (in accordance with National & Local Regulations) Installation Engineer.
b. The connection of this appliance, and ventilation requirements are to be according to National & Local Codes.
c. The chimney should be swept before the appliance is installed.
d. Open fires are a hazard; it is recommended that a guard be fitted to provide protection for children, the elderly or infirm. (See
National & Local Regulations if any.)
e. This appliance is intended for decorative purposes only.
f. Do not throw rubbish on, or attempt to burn any materials on this appliance. Any debris or foreign matter must be removed
from the fire.
g. The appliance should be serviced by a qualified gas fitter every 12 months.
a. This appliance is fitted with an oxygen depletion sensing system, which automatically shuts off the gas supply to the main
burner if the oxygen level in the room is depleted, due to a lack of primary air, or obstructed flue that would lead to incomplete
combustion of the gas.
b. In the event that the fire shuts down due to any reason, attempt to restart it. If there is a continuing problem call in a properly
qualified specialist engineer.
c. There are no user replaceable parts in this appliance, except for the logs, Embaglow and black vermiculite available from Nu-
Flame.
d. Regularly inspect the purpose provided ventilator to check that it is free from any obstruction.
e. The chimney should be regularly checked to ensure that all the products of combustion are entering the flue & that there is no
build up of soot. If there is, the appliance must be cleaned.
a. Carefully remove the logs and dust gently with a soft brush so as not to remove the colour finish.
b. Remove the black vermiculite and Embaglow and retain for future use.
c. Carefully dust off the top of the burner with a soft brush. Again taking care not to remove the colour finish.
d. Very carefully remove any debris from the burner slots using a vacuum cleaner taking the utmost care not to damage
the finish on top of the burner.
e. Re-lay as shown in these instructions.
f. The Embaglow is a consumable item and replacements can be obtained from Nu-Flame.
®
Simulated logs manufactured from refractory fibre,
Do not use real logs as this is dangerous.
If the simulated logs need renewing please obtain
GENERAL
IMPORTANT NOTES
CLEANING THE FIRE
Page 1 of 13
IMPORTANT NOTE
are supplied with this appliance.
suitable replacements from a
Nu-Flame stockist.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EVOLUTION BLAZE 600 and is the answer not in the manual?

Questions and answers

Summary of Contents for Nu-Flame EVOLUTION BLAZE 600

  • Page 1 Very carefully remove any debris from the burner slots using a vacuum cleaner taking the utmost care not to damage the finish on top of the burner. e. Re-lay as shown in these instructions. f. The Embaglow is a consumable item and replacements can be obtained from Nu-Flame. Page 1 of 13...
  • Page 2: Installation & Servicing Instructions

    APPLIANCE SERIAL NO..........INSTALLED BY ........…………………………………. GAS SAFE. NO ........INSTALLATION & SERVICING INSTRUCTIONS FOR NU-FLAME BLAZE 600 NATURAL GAS FIRE THIS APPLIANCE MUST BE INSTALLED & SERVICED BY A PROPERLY QUALIFIED (IN ACCORDANCE WITH LOCAL & NATIONAL CODES) INSTALLATION ENGINEER. IMPORTANT: BEFORE PROCEEDING WITH THE INSTALLATION READ THESE INSTRUCTIONS CAREFULLY.
  • Page 3: Flue Requirements

    INSTALLATION & SERVICING INSTRUCTIONS continued) Natural Gas Model (For G20 Gas) kW Input Net Burner Pressure Fire Model Flue Classes Category Injector Size (High Flame) (High Flame) Class 1 1200 11.2mbar EVOLUTION BLAZE 600N FLUE REQUIREMENTS a. Ensure that the builders opening, flue & hearth for the appliance are constructed from non-combustible materials, and conform to National Regulations and Local Codes.
  • Page 4 INSTALLATION & SERVICING INSTRUCTIONS continued) As the Blaze 600 is a sunken burner this requirement (A) is crucial and must be strictly adhered to Built in warm air rear outlet. Do not remove, block or Please ensure battery wire doesn’t touch base of pan 75cm free area minimum cover other than curved piece of central back logs.
  • Page 5 Page 5 of 13...
  • Page 6: Basic Reset

    IMPORTANT NOTE THIS APPLIANCE MUST BE INSTALLED & SERVICED BY A PROPERLY QUALIFIED (IN ACCORDANCE WITH LOCAL & NATIONAL CODES) GAS INSTALLATION ENGINEER. THESE INSTRUCTIONS ARE FOR THE FIRE’S CONTROL SYSTEM ONLY, AND MUST BE USED IN CONJUNCTION WITH THE INSTALLATION INSTRUCTIONS FOR THE GAS FIRE.
  • Page 7 INSTALLATION & SERVICING INSTRUCTIONS continued) General The Thermatronic Control System is a battery operated gas fire control system that uses a microprocessor to provide the working sequences needed by the fire, and when used with an oxypilot has all the safety features required by law and CE approval.
  • Page 8: Installation Of The Appliance

    INSTALLATION & SERVICING INSTRUCTIONS continued) INSTALLATION OF THE APPLIANCE Ensure that: The appliance application is correct. The flueing is correct The room ventilation of 100cm free area is provided. The gas pipe work is sized to provide 13kW nett to the 8mm outside diameter connection to the burner. a.
  • Page 9 INSTALLATION & SERVICING INSTRUCTIONS continued) LAYOUT FOR SIMULATED LOGS 10-piece charred set. ←← Placement of charred set. Keep burner slots clear Using the 2 Embaglow and about half a packet of the black vermiculite, firstly tease out the Embaglow to cover the 12 burner slots.
  • Page 10 INSTALLATION & SERVICING INSTRUCTIONS continued) Lay back log and forked log as shown Place large central log as shown. Place small log in front of the pilot cut out but ensure it does not cover the pilot cut out or interfere with it in any way.
  • Page 11: Commissioning The Fire

    INSTALLATION & SERVICING INSTRUCTIONS continued) COMMISSIONING THE FIRE a. Close all doors and windows, check operation of controls and burn for 5 minutes. Test for spillage of the flue products using a smoke match. Pass the lighted match along the top front edge, just inside the fire opening. If there is a small amount of spillage, run the fire for a further 10 minutes and re-test for spillage.
  • Page 12 Nu-Flame. If we are not able to resolve the problem over the phone we may ask you to return the fire, and will log your details and give you a return reference number.
  • Page 13 Page 13 of 13...