  • Page 1 All-in-One ESS (LV) RW-F5.3-1H3 SKU: 9430 Version: V1.1...
  • Page 2: Table Of Contents

    Contents 1.Product Introduction ............................1 2.Specifications ..............................1 3.Unpacking Guide .............................. 3 4.Packing List ...............................3 4.1 Parts List ..............................3 5.Security Introduction ............................4 5.1 Preparation Before Connection ......................4 5.2 In Use ..............................4 6.Quick Guide ..............................5 6.1 Product Dimensions ..........................5 6.2 Operation Interface ..........................6 6.3 Display ICONS ............................
  • Page 3: Product Introduction

    1.Product Introduction RW-F5.3-1H3 is a new energy storage product developed and produced, which can be used to support the reliable power supply of various equipment and systems. The RW-F5.3-1H3 features an integrated design with a 5kW hybrid inverter, 5.3kWh LFP battery and intelligent applications.
  • Page 4 Protection IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD Grid Regulation 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 Safety EMC / Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 General Data Cooling Natural Cooling Other Parameter Operating Temperature(℃) Operating Temperature(℃) Humidity 15% ~ 85% (No Condensing)
  • Page 5: Unpacking Guide

    3.Unpacking Guide Check the outer packing Before unpacking the outer package, check the outer package for visible damage, such as holes, cracks, or other signs of possible internal damage, and check the energy storage model. If there is any abnormal packaging or energy storage model does not match, do not open, and contact your dealer as soon as possible.
  • Page 6: Security Introduction

    5.Security Introduction Warning It is very important and necessary to read the user manual (attached) carefully before installing or using the battery. Failure to do so or to follow any instructions or warnings in this document may result in electric shock, serious injury, or possible damage to the battery, rendering it inoperable. If the battery is stored for a long time, it is recommended to charge the product once a month or So, and the Soc should not be less than 50% .
  • Page 7: Quick Guide

    6.Quick Guide 6.1 Product Dimensions...
  • Page 8: Operation Interface

    6.2 Operation Interface Front panel display Description Function Button exit mode Go back to the previous choice Down skip to the next selection Enter confirm selection...
  • Page 9: Display Icons

    6.3 Display ICONS Product Overview...
  • Page 10: Mechanical Installation

    7.Mechanical Installation 7.1 Considering the following points before selecting where to install: Please select a vertical wall with load-bearing capacity for installation, suitable for installation on  concrete or other non-flammable surfaces, installation is shown below. Install this inverter at eye level in order to allow the LCD display to be read at all times. ...
  • Page 11 Wall mounting bracket installation...
  • Page 12: Product Wiring Instructions

    8.1 Cables for Battery Expansion Easy to expand, support multiple parallel, support up to 16 all-in-one parallel(57.6kW/84.8kWh). At the same time, it also supports Deye 5.3kWh battery expansion,supporting a maximum of 31 battery packs in parallel with a maximum capacity of 169kWh.
  • Page 13: Parallel Capacity Expansion

    8.3 Parallel Capacity Expansion...
  • Page 14: Typical Application Diagram Of Diesel Generator

    8.4 Typical Application Diagram of Diesel Generator...
  • Page 15: Single Phase Parallel Connection Diagram

    8.5 Single Phase Parallel Connection Diagram...
  • Page 16: Three Phase Parallel Inverter

    8.6 Three Phase Parallel Inverter...
  • Page 17: Working Mode

    9.Working Mode 9.1 Solar Power Curve...
  • Page 18: Curve Page-Solar & Load & Grid

    9.2 Curve Page-Solar & Load & Grid...
  • Page 19: System Setup Menu

    9.3 System Setup Menu 9.4 Basic Setup Menu...
  • Page 20: Battery Setup Menu

    9.5 Battery Setup Menu...
  • Page 22: System Work Mode Setup Menu

    9.6 System Work Mode Setup Menu...
  • Page 24: Grid Setup Menu

    9.7 Grid Setup Menu...
  • Page 25: The Method Of Cei-021 Standard Self-Check

    9.8 The Method of CEI-021 Standard Self-Check...
  • Page 27: Generator Port Use Setup Menu

    9.9 Generator Port Use Setup Menu...
  • Page 28: Advanced Function Setup Menu

    9.10 Advanced Function Setup Menu...
  • Page 29: Device Info Setup Menu

    9.11 Device Info Setup Menu...
  • Page 30: Fault Content

    10.Fault Content 10.1 Fault Information and Processing The energy storage inverter is designed according to the grid-connected operation standard and meets the safety requirements and electromagnetic compatibility requirements. Before leaving the factory, the inverter undergoes several rigorous tests to ensure that the inverter can operate reliably. If any of the fault messages listed in Table7-1 appear on your inverter and the fault has not been removed after restarting, please contact your local dealer or service center.
  • Page 31 Byte1: bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0 Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 Heating film Mos over Cell Cell voltage over temperature temperature over Reserved Reserved Temperature over difference Reserved Reserved Difference (Errcode:14) (Errcode:13) (Errcode:11) (Errcode:12) For example, parse blue font failure and convert it to binary That is: byte2: bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0 Bit7...
  • Page 32 For example, parse the green font failure and convert it to binary That is: byte6: bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0 Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 CHG_VOLT TEMP_OPE VOLT_OP Charge Pre Charge _LOW N_WIRE_F EN_WIRE_ FUSE Blown OverTermi OverConnect...
  • Page 33 PV isolation resistance is too low 1.Check the connection of PV panels and inverter is firmly DC insulation impedance and correctly. failure 2.Check whether the PE cable of inverter is connected to ground. 3.Seek help from us,if can not go back to normal state. 1.Please wait for a while and check whether it is normal.
  • Page 34 3.Seek help from us,if can not go back to normal state. 1.it tells the communication between hybrid inverter and battery BMS disconnected when"BMS_Err-Stop"is active. BMS communication 2.if don't want to see this happen,you can disable fault "BMS_Err-Stop"item on the LCD. 3.If the fault still exists,please contact us for help.
  • Page 35: Faq

    11.FAQ Q1: What type of battery does the product use? Is it safe? Use high-quality lithium iron phosphate batteries. system multiple protection strategy, charge overload protection, discharge overload protection, to ensure the safe and normal operation of the battery. Q2: How to judge the product in charge and discharge? When charging, the LCD display displays the remaining charging time, the power indicator chart outside the battery power percentage starts to rotate, and displays the input power.
  • Page 36: After-Sales Service

    12.After-Sales Service During the use of the product, according to the normal operation of the user manual can not discharge the fault, please contact the dealer in time, and give clear feedback to the after-sales personnel: product model, purchase date, contact phone number, fault phenomenon. 1.The product warranty period is 10 years.The shelf life is calculated from the date of purchase by the consumer.