Download Print this page
Avigilon OP-CR-SDC Quick Start Manual

Avigilon OP-CR-SDC Quick Start Manual

Single door controller
Hide thumbs Also See for OP-CR-SDC:

Advertisement

Quick Links

Single Door Controller
Quick Start Guide
OP-CR-SDC
What's Included
Single Door Controller
Cover
Mounting backplate
Drywall anchors
Electrical box screws
Set screw for securing
SDC to backplate
Self-tapping screws
Hex key for set screw
Overview
1
Admin button, Status LED indicator
2
Ethernet port
3
USB ports
4
Port LED indicators
Status LED Indicator
Status LED
Description
Solid white
Normal operation
Solid cyan
Booting
Solid yellow
Restoring software
Blinking yellow
Updating software
Solid blue
Unprovisioned state
Solid purple
Connected to Avigilon Alta Access app
Blinking purple
Ready to connect to Avigilon Alta Access app
Blinking red
No internet
Solid red
Error, see Avigilon Alta Control Center
Port LED Indicators
Port LED
Description
Avigilon readers or Wiegand Readers
Solid
Normal operation
Blinking
Error state
Sensors, including REX and Contact Sensors
Solid
Active
Blinking
EOL shorted or cut
Lock hardware including relays
Solid
Relay is energized
Blinking
Fault detection
1 - Mounting
1. Attach the backplate to a single or double gang box using the included electrical
box screws (two or four screws, respectively).
Tip: Use the included drywall anchors and self-
tapping screws on drywall for added stability.
2. Snap the Single Door Controller onto the backplate. Ensure the side clips on the
backplate (a) fit into their notches on the back of the controller (b).
3. Use the included hex key to tighten the pre-installed set screw on the Single Door
Controller to secure it to the backplate.

Advertisement

loading
Need help?

Need help?

Do you have a question about the OP-CR-SDC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Avigilon OP-CR-SDC

  • Page 1 Unprovisioned state Solid purple Connected to Avigilon Alta Access app Blinking purple Ready to connect to Avigilon Alta Access app 2. Snap the Single Door Controller onto the backplate. Ensure the side clips on the Blinking red No internet backplate (a) fit into their notches on the back of the controller (b).
  • Page 2 24V. Caution: Use only the Power Sourcing Equipment certified by UL 62368-1 (compliant with LPS) © 2024, Avigilon Corporation. All rights reserved. AVIGILON and the AVIGILON logos are trademarks or for the Single Door Controller (Power Limited/Class2). registered trademarks of Avigilon Corporation. All other trademarks are the property of their respective Example: North American power cord and outlet Caution: Certified external power source (complies with LPS) must be used.