Large display pulse input counter & frequency meter.
connection details, scaling and general information (21 pages)
Summary of Contents for London Electronics FUSION-H
Page 1
Model FUSION-H Installation & Operating Manual Revision 26 Caution: There is a risk of electrical shock if this instrument is not properly installed Caution: Risk of danger: Read the whole manual before you install this meter F H00.33 Version 1.0 www.london-electronics.com...
FUSION-H Users Manual Table of Contents Warranty ..............................1 Warnings ..............................2 Introduction............................3 General Description ..........................4 Suspension Mounting Dimensions......................5 Wall Mounting Dimensions........................6 Panel Mounting Dimensions ........................7 Connections............................8 Connections............................9 Installation Hints For Best Performance ...................10 Easy or Advanced Menu Mode......................12 Display Brightness ..........................13 Modes Setting ............................14...
Page 3
FUSION-H Users Manual How To Install Option Boards ......................26 Waste Electrical Electronic Equipment (WEEE) ................27 Equipment Specifications........................28 Record of Revisions..........................29 Notes..............................30 Declaration of UK & CE Conformity....................31 www.london-electronics.com...
FUSION-H Users Manual Warranty We warrant this product against defects in materials or workmanship for a period of three (3) years from the date of purchase. In the event of a defect during the warranty period, the unit should be returned, freight (and all duties and taxes) prepaid by the Buyer to the authorised distributor from where the unit was purchased.
FUSION-H Users Manual Warnings Please carefully read this manual and all warnings. Install the meter ONLY when you are sure that you’ve covered all aspects. Where the product is intended for “UL” installations, removal or addition of option boards is not permitted.
FUSION-H Users Manual Introduction Please contact us if you need help, if you have a complaint, or if you have suggestions to help us improve our products or services. If you contact us about a product you already have, please tell us the full model number and serial number, so that we can give you accurate and fast help.
FUSION-H Users Manual General Description This series of displays accepts industrial sensors to allow various physical measurements to be made, such a weight, temperature, pressure, humidity etc. Different models are available for different sensor types. The main function of this series is to give a numeric readout of the variable being monitored.
FUSION-H Users Manual Suspension Mounting Dimensions 15mmO 15mmO 6.35mmO 6.35mmO Plan View 25mm X mm Y mm Short-drop mounting holes Long-drop mounting holes W mm 77 mm 8.8.8.8.8.8. H mm H mm 25mm Cable Glands. Number of glands depends on installed options.
FUSION-H Users Manual Wall Mounting Dimensions 98 mm W mm 22mm 60 mm 8.8.8.8.8.8. H mm 25mm Cable Glands. Number of glands depends on installed options. 80 mm 60 mm The 4 bracket holes are 5.2mm diameter 60 mm X mm 72.5 mm...
FUSION-H Users Manual Panel Mounting Dimensions 67mm 8.8.8.8.8.8. 25mm H mm A mm Neoprene Bezel W mm gasket Neoprene Cable glands gasket B mm Detail showing bracket hardware fitting sequence Bezel Panel cutout dimensions Neoprene gasket Panel A+3mm(h) x B+3mm(w)
FUSION-H Users Manual Warning: Connections Disconnect all power before removing the rear of the display There is a wide range of possible locations for the input board, output board and power supply board/s. Their locations depend on the height of digits, number of digits, brightness of digits and any installed options.
FUSION-H Users Manual Connections Warning: Disconnect all power before removing the rear of the display Output option board (if fitted) Connectors and options Analog Connectors may be Serial Data 0, 2 or 4 Alarm Relay output present even if output...
FUSION-H Users Manual Installation Hints For Best Performance This section offers several suggestions which will help you get the best performance from your measurement system. The logic input signals are comparatively small and can easily be corrupted by the comparatively high level of electrical noise which can be created by electrical machinery such as motors, welding systems, discharge lighting, AC power inverters and solenoids.
FUSION-H Users Manual Easy or Advanced Menu Mode You can choose from two menu modes. 1. Easy Mode - This limits the menu to the most commonly required features, in order to make it less complex and easier to navigate. This is the default level.
FUSION-H Users Manual Display Brightness You can adjust the display brightness at any time, provided the display is locked. Set1 Set2 Output Alarms Digit Lockout Switch must be ON Max/Min Reset Circuit board Press 3 seconds Set1 Set2 Output Alarms...
FUSION-H Users Manual Modes Setting The display’s calendar and internal clock will need to be set whenever the battery is renewed, and the clock may need to be set from time to time, if it is not synchronised to a master time source, such as our NTP upgrade.
FUSION-H Users Manual Basic Clock Configuration If the display is being used in Clock Mode, the following basic configurations will be available ..This feature is available in Easy and Advanced Modes Set2 Output Set1 Alarms Lockout Switch must be OFF...
FUSION-H Users Manual Timer Mode Settings If the display is being used in Timer Mode, the following basic configurations will be available ..This feature is available in Easy and Advanced Modes Set1 Set2 Output Alarms Lockout Switch must be OFF...
FUSION-H Users Manual RTC Setup Method The display’s calendar and internal clock will need to be set whenever the battery is renewed, and the clock may need to be set from time to time, if it is not synchronised to a master time source.
FUSION-H Users Manual Factory Defaults You can return the display to its factory default conditions whenever you wish. If you do so, you will permanently loose all your settings and will need to start from the beginning again. The calibration Audit Counter will NOT be reset, there is no way provided to reset this value, as it is intended as a secure record to indicate whether changes have been made to the display since it was last calibrated..
FUSION-H Users Manual Logic Input Functions The three contact closure inputs on the rear of the meter have default functions which are:- Contact closure 1 = Start (starts timing period, clears display to 0 or preset) Contact closure 2 = Stop...
FUSION-H Users Manual Logic Input Connections & Front Buttons The logic input provides a 5V DC signal. When you connect this to common, a current of 1mA will flow. Because this is a small signal, we recommend you use switches with gold plated contacts, or self cleaning contacts, for best long term reliability.
FUSION-H Users Manual Menu Timeout Adjustment The display has a default timeout of 60 seconds, to allow you sufficient time to refer to the manual between key operations. You can make this period shorter, if you wish, once you become more familiar with the setup method.
FUSION-H Users Manual Reverse Display Function (Mirror Image) If you need to be able to see a reflection of the display in a mirror or other reflective surface, for example in a simple heads-up system, or for drivers reversing into a bay, using mirrors only, you can set the display to show as a mirror image.
FUSION-H Users Manual Bootup Routine & Tare Save Choices When you switch on your meter, it can be set to power up with 3 possible summary message combinations. The choices are:- = Segment test, followed by a full summary of software revision, calibration audit number, model number, installed options.
FUSION-H Users Manual Language Selection for User Interface You can select English or French menu prompts. Set1 Set2 Output Alarms Digit Max/Min Reset Lockout Switch must be OFF Press together, briefly Circuit board Display shows Set2 Output Set1 Alarms L.Eng...
FUSION-H Users Manual Error Codes & Fault Findings 1. Time does not automatically correct at summer/winter time changeover. Check that the has been set to your region. Page 25 www.london-electronics.com...
FUSION-H Users Manual How To Install Option Boards Warning: Disconnect Where the product is intended for “UL” installations power before you expose removal or addition of option boards is not permitted. the internals of the display If you want to open your display to install or modify option boards, follow these steps...
FUSION-H Users Manual Waste Electrical Electronic Equipment (WEEE) In Europe, this equipment must be disposed of in accordance with European parliamentary Directive 2002/96/EC This directive encourages recycling and the reduction of waste materials in the environment. This means it must be sent to an approved recycling plant if you want to dispose of it.
FUSION-H Users Manual Record of Revisions 6 September 2010 Version F00.18 Software released. Manual format revised to improve clarity and segregate easy from advanced menu functions. Optional outputs now described in their own dedicated manuals. DIN Rail mounting option added. Cabling guidance added.
Signal cabling shall be routed separately to power carrying cabling (includes relay output wiring) All signal cabling shall be screened. The screen shall only be terminated to the power earth terminal at the meter end of the cable. Declared as true and correct, for and on behalf of London Electronics Ltd. J.R.Lees Director Page 31 www.london-electronics.com...
Need help?
Do you have a question about the FUSION-H and is the answer not in the manual?
Questions and answers