This chapter describes the installation procedure for the 10/100 Fast Ethernet
Switch. The chapter includes information on installation, connecting power,
connecting network cables, setting the port duplex mode, and some network
configuration examples.

Installation Site

When installing the switch, choose a sturdy, level surface in a ventilated area
that is dust free and away from heat vents, warm air exhaust from other
devices and direct sunlight. Avoid proximity to large electric motors or other
electromagnetic equipment.
Observe the following guidelines when choosing a location for the 10/100
Fast Ethernet Switch:
The surface must support at least 3.0 kg (6.5 lbs).
Air temperature should range from 32 to 122 F (0 to 50 C).
Humidity should be less than 90%, non-condensing.
Site should not exceed the electromagnetic field (RFC) standards for IEC
801-3, Level 2 (3V/M) field strength.
The power outlet should be within 6 feet of the device.

Installation