Download Print this page
KPS KPSLX10CBINT Instruction Manual

KPS KPSLX10CBINT Instruction Manual

Digital light meter

Advertisement

Available languages

Available languages

Quick Links

MANUAL DE FUNCIONAMIENTO
INSTRUCTIONS MANUAL
MANUEL D'INSTRUCTIONS
Luxómetro digital
Digital light meter
Luxmètre numérique
KPS-LX10
SKU: KPSLX10CBINT

Advertisement

loading
Need help?

Need help?

Do you have a question about the KPSLX10CBINT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for KPS KPSLX10CBINT

  • Page 1 MANUAL DE FUNCIONAMIENTO INSTRUCTIONS MANUAL MANUEL D’INSTRUCTIONS Luxómetro digital Digital light meter Luxmètre numérique KPS-LX10 SKU: KPSLX10CBINT...
  • Page 2: Descripción Del Panel Frontal

    KPS-LX10 • Luxómetro digital CARACTERÍSTICAS • Lectura fácil y precisa. • Alta precisión y amplia escala de medición. • El uso de un circuito LSI proporciona una gran fiabilidad y durabilidad. • Indicador de BATERÍA BAJA integrado. • La pantalla LCD permite una fácil lectura incluso en lugares con gran iluminación.
  • Page 3: Especificaciones

    KPS-LX10 • Luxómetro digital (1) Tecla HOLD (retención) (2) Fotodetector (3) Pantalla LCD (4) Interruptor de funciones (5) Tecla de encendido ESPECIFICACIONES 3-1 Especificaciones generales • Condiciones ambientales: - Temperatura de funcionamiento: 0ºC a 40ºC≤80% HR, sin condensación - Temperatura de almacenamiento: -10ºC a 60ºC ≤70% HR, sin pila •...
  • Page 4: Procedimiento De Medición

    KPS-LX10 • Luxómetro digital Nota: precisión comprobada por medio de una lámpara de tungsteno estándar en paralelo a una temperatura de 2854ºK. 3-3 Factor de corrección • Lámpara de mercurio:........x1.1 • Lámpara fluorescente: ........x1.0 • Lámpara incandescente: ........ x1.0 •...
  • Page 5: Mantenimiento

    KPS-LX10 • Luxómetro digital MANTENIMIENTO 6-1 Mantenimiento general • Para mantener limpio el instrumento, limpie la carcasa con un paño seco y detergente. No emplee productos abrasivos ni disolventes. • Cuando sea necesario, el disco de plástico blanco de la parte superior del detector se deberá...
  • Page 6 KPS-LX10 • Luxómetro digital • Hospitales • Habitación, almacén ...........100 ~ 200 • Sala de exploración médica.........200 ~ 750 • Quirófano, emergencias ..........750 ~ 1500 • Emergencias ...............750 ~ 1500 • Centros de enseñanza • Auditorio, gimnasio interior ..........100 ~ 300 •...
  • Page 7: Front Panel Description

    KPS-LX10 • Digital light meter FEATURES • Precise and easy readout. • High accuracy and wide measurement range. • LSI-circuit use provides high reliability and durability. • In build LOW BATTERY indicator. • LCD display allows clear read out even at bright places.
  • Page 8 KPS-LX10 • Digital light meter (1) HOLD key (2) Photo Detector (3) LCD display (4) Function switch (5) POWER key SPECIFICATIONS 3-1 General specifications • Environment conditions: - Operating temperature: 0ºC to 40ºC ≤ 80% RH, noncondensing - Storage temperature: -10ºC to 60ºC ≤ 70% RH, battery removed •...
  • Page 9: Measuring Procedure

    KPS-LX10 • Digital light meter 3-3 Correction Factor • Mercury Lamp ........x1.1 • Fluorescent Lamp ......x1.0 • Incandescent Light......x1.0 • Daylight ..........x1.0 SPECTRUM FOR PHOTO DETECTOR 1000 Longitud de onda (nm) MEASURING PROCEDURE • Power-up: Press the POWER key to turn the meter on.
  • Page 10: Recommended Illumination

    KPS-LX10 • Digital light meter • Any adjustment maintenance and repair shall be by a qualified person. 6-2 Battery Replacement • When the battery voltage drop below proper operation range, the “ ” symbol will appear on the LCD display and the battery needs to be replaced.
  • Page 11: Description Du Panneau Avant

    KPS-LX10 • Luxmètre numérique CARACTÉRISTIQUE • Lecture facile et précise. • Haute précision et grande échelle de mesure. • L’utilisation d’un circuit LSI fournit une grande fiabilité et durabilité. • Indicateur intégré de BATTERIE FAIBLE. • L’écran LCD permit une facile lecture même dans des lieux avec un éclaira- ge de haute intensité.
  • Page 12: Spécifications

    KPS-LX10 • Luxmètre numérique SPÉCIFICATIONS 3-1 Spécifications générales • Conditions environnementales: - Température de fonctionnement: 0ºC à 40ºC≤80% HR, sans condensation - Température de stockage: -10ºC à 60ºC ≤70% HR, sans pile • Principe de fonctionnement: intégration à double pente •...
  • Page 13 KPS-LX10 • Luxmètre numérique SPECTRE POUR LE PHOTODÉTECTEUR 1000 Longitud de onda (nm) PROCÈDURE DE MESURE • Allumage: appuyez sur le bouton d’allumage pour allumer l’appareil. • Sélection de l’échelle de LUX: placez le sélecteur de fonctionnes dans l’échelle souhaitée.
  • Page 14 KPS-LX10 • Luxmètre numérique 6-2 Remplacement de la pile • Lorsque la tension de la pile sera inférieure à celle nécessaire pour garantir le fonctionnement adéquat, l’écran montrera le symbole “ ” et sera né- cessaire le remplacement de la pile.
  • Page 15 (ENG) KPS guarantees this device during 2 years against any manufacturing defect. (FRA) KPS garantit cet appareil pour une durée de 2 ans contre tout défaut de fabrication. (POR) KPS garantía este aparelho contra defeitos de fábrica ate 2 anos.
  • Page 16 APAC: MGL GLOBAL SOLUTIONS LTD AMERICAS: MGL AMERICA, LLC. info.apac@mgl-intl.com info.na@mgl-intl.com Flat 4-1, 4/F, No. 35, Section 3 Minquan US East Coast: 2810 Coliseum Centre East Road. Taipei, Taiwan. Drive, Ste. 100. Charlotte, North Caroli- Tel: +886 2-2508-0877 na, 28217 USA Tel: +1 833 533-5899 EMEA: MGL EUMAN S.L.