Advertisement

Quick Links

05147
D
GB
F
NL
I
TR
CZ
PL
RUS
H
 
Operating instructions
Actuator IC 40
Cert. version 06.19

Contents

Contents
Actuator IC 40. . . . . . . . . . . . . . . . . . . . . . . . . . 1
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Checking the usage . . . . . . . . . . . . . . . . . . . . . 
Type code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Part designations . . . . . . . . . . . . . . . . . . . . . . . . 2
Type label. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Connection diagram. . . . . . . . . . . . . . . . . . . . . . 3
Feedback. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Commissioning. . . . . . . . . . . . . . . . . . . . . . . . . 5
LED display . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Opto-adapter PCO 200 . . . . . . . . . . . . . . . . . . . 5
Opto-adapter PCO 300 . . . . . . . . . . . . . . . . . . . 5
BCSoft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . 8
Logistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
E
DK
S
N
P
GR
www.docuthek.com

Safety

Safety
Please read and keep in a safe place
Please read through these instructions
carefully before installing or operating. Following the
installation, pass the instructions on to the opera-
tor. This unit must be installed and commissioned
in accordance with the regulations and standards
in force. These instructions can also be found at
www.docuthek.com.
Explanation of symbols
• , 1 ,  ,  ... = Action
= Instruction
Liability
We will not be held liable for damage resulting from
non-observance of the instructions and non-com-
pliant use.
Safety instructions
Information that is relevant for safety is indicated in
the instructions as follows:
DANGER
Indicates potentially fatal situations.
WARNING
Indicates possible danger to life and limb.
CAUTION
Indicates possible material damage.
All interventions may only be carried out by qualified
gas technicians. Electrical interventions may only be
carried out by qualified electricians.
Conversion, spare parts
All technical changes are prohibited. Only use OEM
spare parts..
GB-1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IC 40 and is the answer not in the manual?

Questions and answers

Summary of Contents for krom schroeder IC 40

  • Page 1: Table Of Contents

    Contents Indicates potentially fatal situations. Actuator IC 40......1 WARNING Contents ......1 Indicates possible danger to life and limb.
  • Page 2: Actuator Ic 40

    IBAF IC 40 + BVAF (for air, clearance-free valve) ment is designed to adjust volumes of gas and air IC 40 + BVH (for hot air and flue gas) on various appliances and flue gas lines. IC 40 is IBHS IC 40S + BVHS (for hot air and flue gas, adjusted and commissioned using the BCSoft V4.x...
  • Page 3: Connection Diagram

    ▷ Use cables with wire end ferrules. Wiring ▷ Cable cross-section: max. 2.5 mm². ▷ For information on assignment of the inputs and WARNING outputs, see www.docuthek.com → Thermal Electric shocks can be fatal! Solutions → Products → 03 Valves and butterfly Before working on electrically live components, –...
  • Page 4: Feedback

    ▷ The film on the marking must be clean and un- damaged. ▷ When connecting to BCSoft, a connection to the IC 40 is established from the PC/notebook. ▷ Re-tighten the cover screws in order to ensure ▷ If a connection fails to be established, the proce- that the housing cover is grounded.
  • Page 5: Commissioning

     Select the butterfly valve fitted in the “Actuator mounted on” menu item. registration in the DOCUTHEK is required. ▷ Actuators IC 40 up to construction stage C can BVH, BVHS only be parameterized with BCSoft version 3.x.x, 4 Select “Start calibration”.
  • Page 6: Adapter Set For Butterfly Valve Dkl, Dkg

    Order No.: 74921671 may only be carried out by authorized personnel) Maintenance Actuators IC 40 suffer little wear and require little ser- vicing. We recommend a function check once a year. If the “Service note” option has been activated in...
  • Page 7 ! Flashes 6 times: saving error for adjustable pa- ? The drive shaft does not move? rameters. ! No permanent voltage supply to the unit. • Carry out reset. • Check supply voltage. • If it is not possible to remedy the fault, send the ! No signal at the unit.
  • Page 8: Technical Data

    Enclosure: ? The motor and drive shaft of the actuator IC 40: IP 54, in conjunction with BVH: IP 65, IC 40: Nema 2, in conjunction with BVG, BVA or no longer function as required? BVH: Nema 3.
  • Page 9: Logistics

    4.5 – 76.5 IC 40S 4.5 – 76.5 Transport On the IC 40, the running time and torque are Protect the unit from external forces (blows, shocks, independent of the mains frequency. The running vibration). time can be freely programmed between the limits Transport temperature: see page ...
  • Page 10: Disposal

    Eurasian Customs Union Disposal Devices with electronic components: WEEE Directive 01/19/EU – Waste Electrical and Electronic Equipment Directive The product IC 40 meets the technical specifications of the Eurasian Customs Union. At the end of the product life (number of operat- ANSI/CSA approved ing cycles reached), dispose of the packaging and product in a corresponding recycling centre.