Page 1
Manual of assembly and safe use of the ENCOR photovoltaic module Polish manufacturer [does not refer to BIFACIAL modules] of photovoltaic systems Year of release: 2024 version: 3 Translation No.: INS 002/0000.0001.0000/2024/003 en.corab.pl photovoltaic...
Page 2
Manual and other manuals, please contact sions of the act on occupational health and safety Corab S.A. at the following e-mail address: serwis@co- or the local regulations on fall protection. rab.com.pl / phone no. 089 650 13 99.
Page 3
Keep children away from the system during trans- port and assembly of the mechanical and electri- cal components. ▪ Use only insulated tools that have been approved for work on electrical systems. ▪ During the assembly and removal of faults, do not Page 3 of 14 en.corab.pl...
Page 4
This Follow the instructions of the provider of clamps. fact must be consulted with the manufacturer and Clamps provided by Corab S.A. are recommen- the installation should be carried over after the ded.
(in case of vertical orientation) or two clamps at each of the short sides of the module (in Construction case of horizontal orientation). Depending on the local profile Fig. 2. Page 5 of 14 en.corab.pl...
Page 6
(1/4L-50)<S<(1/4L+50) [mm] Test load: pressure 1600 Pa/suction 1600 Pa Test load: pressure 5400 Pa/suction 2400 Pa Design load: pressure 1067 Pa/suction 1067 Pa Design load: pressure 3600 Pa/suction 1600 Pa (1/2L-50)<S<(1/2L+50) [mm] 0<H<1/4W [mm] 0<H<1/4W [mm] Page 6 of 14 en.corab.pl...
Page 7
Load of 1600 Pa directed to the top of the module Load of 3600 Pa directed to the bottom of the module method 285≤S≤385 [mm] 285≤S≤385 [mm] L=1903 [mm] L=1903 [mm] Load of 2400 Pa 81≤H≥255 [mm] W=1134 [mm] Page 7 of 14 en.corab.pl...
Page 8
Design load: pressure 3600 Pa/suction 1600 Pa Design load: pressure 3600 Pa/suction 2400 Pa method (1/2L-80)<S<(1/2L-30) [mm] (1/5L-50)<S<(1/5L+50) [mm] (1/6L-50)<H<(1/6L+50) [mm] Test load: pressure 2400 Pa/suction 2400 Pa Design load: pressure 1600 Pa/suction 1600 Pa Page 8 of 14 en.corab.pl...
Page 9
Table 8. Installation of EC480N-10-120B, EC505N-10R-120B N-TYPE modules Side of assembly Test load: pressure 5400 Pa/suction 2400 Pa / Assembly Design load: pressure 3600 Pa/suction 1600 Pa method 350≤S≤450 [mm] Load of 2400 Pa 150≤H≤250 [mm] Page 9 of 14 en.corab.pl...
Page 10
Long-term exposure to a humid environment ▪ The maximum number of series of connected might result in a weak connection of the connec- modules depends on the design of the system, tors, current leakage and low conductivity which Page 10 of 14 en.corab.pl...
Page 11
Table 7 for the voltage in the modules. circuit. Photovoltaic modules can be grounded with accessories Page 11 of 14 en.corab.pl...
Page 12
Never start cleaning a photovoltaic module with a according to the instructions provided by the manufacturer. It cracked pane or with other signs of uncovered wires is recommended to use earthing provided by Corab S.A. because it poses the risk of electrocution. ▪...
Page 13
The manufacturer of the module shall reserve the right to make changes in the manual, the photovoltaic product, specification or technical data sheet of the product without prior notice. Page 13 of 14 en.corab.pl...
Page 14
Corab S.A. ul. Michała Kajki 4, 10-547 Olsztyn, REGON: 510519084, NIP: 7390207757 entered into the National Court Register managed by Corab S.A. ul. Michała Kajki 4, 10-547 Olsztyn, REGON: 510519084, NIP: 7390207757 entered into the National Court Register managed by the District Court in Olsztyn, the 8th Commercial Division of the National Court Register under KRS number: 0000950779.