1. INTRODUCTION TCIDL3 – MID is a three-phase electricity meter with an RS485 and IR communication ports with MODBUS protocol, for DIN rail mounting and indoor usage. This meter complies with the standard EN 50470 – 1/3 for accuracy class B active energy and EN 62053- 23 class 2 for reactive energy.
Page 4
PARAMETER SCROLLING. AUTOMATIC OR SHORT KEY PRESS Page Format integer+ Parameter Unit Remark decimal Total active energy Forward active energy Reverse active energy — T1 Total active energy blink t1 T1 Forward active energy blink t1 T1 Reverse active energy —...
Page 5
Forward maximum reactive power kvar demand Reverse maximum reactive power kvar Pd — demand Voltage L1 Voltage L2 Voltage L3 Voltage L1 L2 Blink L1L2 Voltage L2 L3 Blink L2L3 Voltage L3 L1 Blink L3L1 Current L1 Current L2 Current L3 T56* Total active power Active power L1...
Page 6
T1 Total active energy Blink t1 T1 Forward active energy Blink t1 T1 Reverse active energy — Blink t1 T2 Total active energy Blink t2 T2 Forward active energy Blink t2 T2 Reverse active energy — Blink t2 T3 Total active energy Blink t3 T3 Forward active energy Blink t3...
After phase 3, a long key press access to the information display. INFORMATION DISPLAY Serial number 12 digits MODBUS Address 1 to 247 Baud rate bauds 9600 / 19200 / 38400 / 115200 Parity odd, even, none Stop bits 1 or 2 StoP Automatic scrolling time seconds...
3. FRONT PANEL DESCRIPTION A Model. B Reference standards C Safety, three phase connection and class index symbols. D Reference values. E Data setting key. F Data checking key. G IR port. H Verification leds for active and reactive energy. I CE and metrological marking.
- Do not connect the meter without disconnecting mains voltage. Avoid field work unless another person can assist you. - If the equipment is handled in a way not specified by the manufacturer, the equipment protection may be compromised. - Do not use the meter if its plastic case is damaged and return it to your supplier. The meter must not be opened.
Page 10
C/ Aragoneses, 15. 28108 Alcobendas. Madrid. España. Tel.: 34 - 91 – 519.02.45 Fax. : 34 - 91 - 416.96.46 http://www.saci.es e-mail : saci@saci.es SACI reserves the right to modify this specificatin without prior notice INS-TCIDL3– MID EN 10/10 V.01 01.03.23...
Page 11
MODBUS REGISTER REGISTER DATA R/(W UNIT CONTENT ADDRESS HEX. LENGTH DESCRIPTION INSTANTANEOUS VALUES INT32(3+3) L1 voltage INT32(3+3) L2 voltage INT32(3+3) L3 voltage INT32(3+3) L12 voltage INT32(3+3) L23 voltage 040A INT32(3+3) L31 voltage 040C INT32(3+3) PHASE AVERRAGE VOLTAGE 040E INT32(3+3) LINE AVERAGE VOLTAGE INT32(2+3) L1 Current INT32(2+3)
Page 12
METER PARAMETERS 1000 SERIAL NUMBER 1003 1-247 Modbus ID 1004 FIRMWARE VERSION 1005 HARDWARE VERSION 1006 XXXX CHECKSUM 00, YEAR, MONTH, DAY,WEEKDAY, 1007 HOUR,MINUTE,SECO 0 TO 99 100B SECONDS CYCLE DISPLAY TIME 0 DISABLES 6: 9600. 7: 19200. 8: 100C BAUD RATE 38400.