  • Page 1 ETAF6 Debug Adapter for Renesas SH72xx- Debugger User Guide...
  • Page 2 The data in this document may not be altered or amended without special notification from ETAS GmbH. ETAS GmbH undertakes no further obligation in relation to this docu- ment. The software described in it can only be used if the customer is in possession of a general license agreement or single license.
  • Page 3: Table Of Contents

    CO102 – 26Pin Connector to ECU ............12 4.3.4 CO103 - 36Pin Connector to Debugger / Trace .......... 13 Mechanical Drawings .................... 15 Operating Temperature Range ................15 Ordering Information ..................16 ETAS Contact Addresses ................. 17 ETAF6 User Guide...
  • Page 4: About This Document

    (see chapter "Ordering Information"). Additional cables and adapters can be obtained separately from ETAS. A list of accessories and their order designation is available in this manual and at the ETAS Home Page.
  • Page 5: Safety Information

    Carefully read the documentation (Product Safety Advice and this User Guide) that belongs to the product prior to the startup. ETAS GmbH does not assume any liability for damages resulting from improper handling, unintended use or non-observance of the safety precautions.
  • Page 6 The product is maintenance-free. Use a lightly moistened, soft, lint-free cloth for cleaning the product. Ensure that no moisture can enter. Never spray cleaning agents directly onto the product. Do not user any sprays, solvents or abrasive cleaners which could damage the product. ETAF6 User Guide...
  • Page 7 Cabling Use exclusively ETAS cables at the connections of the product! Adhere to the maximum permissible cable lengths! Observe the assignment of the cables to the connectors! Detailed information about cabling is located in the ETK User Guides.
  • Page 8: Identifications On The Product

    SN: yyxxxxx Serial number (7-digit), depending on product Serial Number is not available. XXXX/YY Product version ZZZZ Year of manufacture ETAS GmbH… Manufacturer's address NOTE For symbols and product information one or several adhesive labels can be used. ETAF6 User Guide...
  • Page 9: Taking The Product Back And Recycling

    ETAS sales and service locations. CE marking With the CE mark attached to the product or its packaging, ETAS confirms that the product corresponds to the applicable product-specific European Directives. The CE Declaration of Conformity for the product is available upon request.
  • Page 10: Introduction

    Adapts to Renesas JTAG or Debugger Plug for debugger connection. There are two specific applications. • Adapt ECU-ETK-Connector to 14 Pin Debugger or 36 Pin Debugger or Trace. • Adapt ETK-Debugger-Connector to 14 Pin or 36 Pin Debugger3D View. View Figure 1: 3D-View ETAF6 User Guide...
  • Page 11: Technical Data

    36Pin Interface to CO103 (AUD trace supported). 4.2.2 Connecting Debugger to ETK Connect CO100 to ETK with the ETAF6 Flatcable. Connect Debugger with 14Pin Interface to Connector CO101 (no AUD trace function) or connect Debugger/Trace with 36Pin Interface to CO103 (no AUD trace function).
  • Page 12: Pin Assignment

    Debug Interface Signal Interface Power JTAG Signal Signal Ground JTAG Signal Signal Ground /RESET Reset Signal Signal Ground 4.3.3 CO102 – 26Pin Connector to ECU Pin Number Signal Description /AUDSYNC Debug Interface Signal /ASEBRKAK Debug Interface Signal Not Connected ETAF6 User Guide...
  • Page 13: Co103 - 36Pin Connector To Debugger / Trace

    Debug Interface Signal Signal Ground AUDATA1 Debug Interface Signal Signal Ground AUDATA2 Debug Interface Signal Signal Ground AUDATA3 Debug Interface Signal Signal Ground /AUDSYNC Debug Interface Signal Signal Ground Not Connected Signal Ground Not Connected Signal Ground JTAG Signal ETAF6 User Guide...
  • Page 14 /DETECT Debugger Detect Signal (Low Active) JTAG Signal Signal Ground JTAG Signal Signal Ground /ASEBRKAK Debug Interface Signal Signal Ground Not Connected Signal Ground /RESET Reset Signal Signal Ground Signal Ground Signal Ground Not Connected Signal Ground ETAF6 User Guide...
  • Page 15: Mechanical Drawings

    ETAS Technical Data Mechanical Drawings Measurements in mm Figure 4: ETAF6 Top View Figure 5: ETAL6 Flat Ribbon Cable Operating Temperature Range Condition Temperature Operating Temperature -40°C - +105°C ETAF6 User Guide...
  • Page 16: Ordering Information

    ETAS Ordering Information Ordering Information Short Name Order Number ETAF6 F 00K 104 773 ETAF1 F 00K 001 373 ETAF6 User Guide...
  • Page 17: Etas Contact Addresses

    Germany WWW: www.etas.com ETAS Subsidiaries and Technical Support For details of your local sales office as well as your local technical support team and product hotlines, take a look at the ETAS website: ETAS subsidiaries WWW: www.etas.com/en/contact.php ETAS technical support WWW: www.etas.com/en/hotlines.php...