Model Numbers
KW
Tank Capacity in Gallons
Input
50
6
DRE-52-6
DRE-80-6
9
DRE-52-9
DRE-80-9
12
DRE-52-12
DRE-80-12
13.5
DRE-52-13.5
DRE-80-13.5
15
DRE-52-15
DRE-80-15
18
DRE-52-18
DRE-80-18
24
DRE-52-24
DRE-80-24
27
DRE-52-27
DRE-80-27
30
DRE-52-30
DRE-80-30
36
DRE-52-36
DRE-80-36
40.5
DRE-52-40.5
DRE-80-40.5
45
DRE-52-45
DRE-80-45
54
DRE-52-54
DRE-80-54
*208 volt models may contain three (3) additional elements.
The heater(s) shall be Dura-Power Commercial Electric Model Number _______________ as manufactured by A.O. Smith Water Products Company
or equivalent. Heater(s) shall be rated at ______________ KW ________ V _____________ phase, 60 cycle AC listed by Canadian Standards
Association. Tank(s) shall be ________ gallon (Liter) capacity. Heater(s) shall have 150 psi (1034 kPa) working pressure and be equipped with
extruded high density anode. All internal surfaces of the heater(s) exposed to water shall be glass-lined with an alkaline borosilicate composition
that has been fused to steel by firing at a temperature range of 1400°F to 1600°F (760° to 870°C). Electric heating elements shall be low watt density
with incoloy sheath and 1" screw-in type. Each element shall be controlled by an individually mounted thermostat and high temperature cut-off
switch. All internal circuits shall be fused (optional). The outer jacket shall be of baked enamel finish and shall be provided with full size control
compartment for performance of service and maintenance through hinged front panel and shall enclose the tank with vermin proof foam insulation.
Electrical junction box with heavy duty terminal block shall be provided. The drain valve shall be located in the front for ease of servicing. Heater
tank shall have a three year limited warranty as outlined in the written warranty. Manufacturer shall supply ASME rated temperature and pressure
relief valve. Fully illustrated instruction manual to be included.
A.O. Smith Water Products Co., Inc. On Line
www.hotwater.com
For Technical Information
Phone: 800-265-8520
A 212.0C
Standard
kW Input
6
9
12
13.5
15
18
24
27
30
36
40.5
45
54
Figured at 1 KW (3413 BTU) = 4.1 Gallons at 100°F temperature rise.
NSF ratings may be obtained by multiplying the above figures by 0.98.
Model
Capacity
Number
gal.
DRE-52
50
DRE-80
80
DRE-120
119
Number
Of
80
119
Elements
DRE-120-6
3
DRE-120-9
3
DRE-120-12
3
DRE-120-13.5
3
DRE-120-15
3
DRE-120-18
3*
DRE-120-24
6
DRE-120-27
6
DRE-120-30
6
DRE-120-36
6*
DRE-120-40.5
9
DRE-120-45
9
DRE-120-54
9
SUGGESTED SPECIFICATIONS
RECOVERY CAPACITY IN GALLONS AT TEMPERATURE RISE OF
BTU/
30°F
40°F
50°F
60°F
Hour
17°C 22°C 28°C 33°C 39°C 45°C 50°C 56°C 61°C 67°C
20,478
82
62
49
310
233
166
155
30,717
123
92
74
465
349
279
233
40,956
164
123
98
620
465
372
310
46,075
184
138
111
698
523
419
349
51,195
205
154
123
102
775
582
465
388
61,434
246
184
148
123
930
698
558
465
81,912
328
246
197
164
1241
930
744
620
92,151
369
276
221
185
1396 1047
938
609
102,390
410
307
246
205
1551
1163
930
775
122,868
492
369
295
246
1861 1396
1117
930
138,226
554
418
332
277
2094 1570 1256 1047
153,585
615
461
369
307
2326 1745 1398
1163
184,302
738
554
443
359
2791 2094 1675 1396
Tank
Dimensions
A
litre
in.
cm
in.
189
55 1/4
140.3
21 3/4
300
59 1/2
151.1
25 1/4
450
62 1/4
158.1
29 1/2
Element
Single Phase
Wattage
208V
240V
2,000
28.8
25.0
3,000
43.3
37.5
4,000
57.7
50.0
4,500
64.9
56.3
5,000
72.1
62.5
6,000
86.5
75.0
4,000
115.4
100.0
4,500
129.8
112.5
5,000
144.2
125.0
6,000
173.1
150.0
4,500
194.7
168.8
5,000
216.3
187.5
6,000
N/A
225.0
A. O. Smith Enterprises Ltd.
A Division of A. O. Smith Corporation
Stratford, Ontario
A. O. Smith Corporation reserves the right to make product changes
or improvements at any time without notice.
© A. O. Smith Corp., 2001
70°F
80°F 90°F 100°F 110°F 120°F 130°F 140°F
41
35
31
27
25
22
133
116
103
93
85
62
53
46
41
37
34
199
174
155
140
127
82
70
61
55
49
45
266
233
207
186
169
92
79
69
62
55
50
299
262
233
209
190
88
77
68
61
56
332
291
258
233
211
105
92
82
74
67
399
349
310
279
254
140
123
109
98
90
532
465
414
372
338
158
138
123
111
101
509
523
465
410
391
176
154
137
123
112
665
582
517
465
423
211
184
164
148
134
798
698
620
556
508
237
208
185
166
151
897
785
698
628
634
263
230
205
184
168
997
872
755
698
634
316
277
246
221
201
1196 1047
930
837
761
Inlet/
B
C
Outlet (NPT)
cm
in.
cm
in.
55.2
27 1/4
69.2
1 1/4
64.1
31 1/4
79.4
1 1/4
75.0
35 3/4
90.8
1 1/4
Full Load Current In Amperes
Three Phase
277V
480V
208V
21.7
12.5
16.7
32.5
18.8
25.0
43.3
25.0
33.3
48.7
28.1
37.5
54.2
31.3
41.6
65.0
37.5
50.0
86.6
50.0
66.6
97.5
56.3
74.9
108.3
62.5
83.3
130.0
75.0
99.9
146.2
84.4
112.4
162.5
93.8
124.9
194.9
112.5
149.9
McBee, South Carolina
El Paso, Texas
Seattle, Washington
Veldhoven, The Netherlands
72°C 78°C
21
19
18
78
72
66
31
28
26
116
107
100
41
38
35
155
143
133
46
43
40
174
161
150
51
47
44
194
149
166
62
57
53
233
215
199
82
76
70
310
286
266
92
85
79
340
322
299
102
95
88
388
358
332
123
113
105
465
429
399
138
128
119
582
537
498
154
142
132
582
537
498
185
170
158
696
644
598
Approx. Ship.
Wt. (Lbs.)
cm
lb
kg
3.2
265
120
3.2
280
127
3.2
390
177
240V
480V
14.4
7.2
21.7
10.8
28.9
14.4
32.5
16.2
36.1
18.0
43.3
21.7
57.7
28.9
65.0
32.5
72.2
36.1
86.6
43.3
97.4
48.7
108.3
54.1
129.9
65.0
Printed in U.S.A.