Summary of Contents for Haier HSU-22CVY03 - annexe 1

  • Page 1: Operation Manual

    SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL HSU-18CVY03 HSU-22CVY03 Please read this operation manual before using the air conditioner No.001051...
  • Page 2 Safety Instructions and Warnings Before disposing an old air conditioner that Before starting the air conditioner, read the goes out of use, please make sure it's inop- information given in the User's Guide caref- erative and safe. Unplug the air conditioner ully.
  • Page 3 3. If the fuse of indoor unit on PC board is broken,please change it with the type of T. 3.15A/ 250V. 4. The wiring method should be in line with the local wiring standard.
  • Page 4: Safety Instruction

    Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. lnstallation in a inadequate place may cause accidents. Do not install in the following place. CAUTION Do not install in the...
  • Page 5 PROHIBITION PROHIBITION CAUTION Take fresh air occasionally especially Do not operate the switch with Do not use for the purpose of storage of food, art work, precise equipment, when gas appliance is running at the wet hand. breeding, or cultivation.
  • Page 6: Parts And Functions

    Vertical flap (adjust up and down air flow. Power plug Don't adjust it manually) Horizontal louver (adjust left and right air flow) For 22k unit, the power plug is on the outdoor unit Outdoor unit HSU-18CVY03 HSU-22CVY03 INLET OUTLET CONNECTING PIPING AND ELECTRICAL WIRING...
  • Page 7 To display the Ambient temp. Used to set clock and timer setting. NOTE:(1) The following functions and related displays are not available: 17 30 (2) Cooling only unit do not have functions and displays related with heating. (3)The SWING LEFT/RIGHT function is optional.(For 18)
  • Page 8 If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later. Hint: Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key.
  • Page 9: Remote Controller

    When indoor fan motor is running, it has healthy process function. (It's available under any mode) When the fan in the indoor unit does not work, the health lamp lights up, but the anion generator does not release anion. BRIEF INTRODUCTION TO HEALTH ANION FUCTION...
  • Page 10: Auto Operation

    STERILIZE decrease 1 C,if kept depressed, it will decrease rapidly Select a desired temperature. 4.Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: AUTO Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
  • Page 11: Cool Operation

    1 C,if kept depressed, it will decrease rapidly Select a desired temperature. 4.Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: AUTO Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
  • Page 12: Dry Operation

    1 C,if kept depressed, it will decrease rapidly Select a desired temperature. 4.Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: AUTO Air conditioner is running under displayed fan speed. In DRY mode, when room temperature becomes COOL operation starts when room lower than temp.setting+2...
  • Page 13: Fan Operation

    Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL Then Select FAN operation 3.Fan speed selection Press FAN button. For each press, fan speed changes as follows: FRESH Remote controller: STERILIZE 4.Unit stop Press ON/OFF button, the unit stops.
  • Page 14: Air Flow Direction Adjustment

    : remote controller: Pos.1 Pos.2 Pos.3 Pos.4 Pos.5 Pos.6 Pos.7 Pos.8 The horizontal louvers will swing according to the above positions. Note:When restart after remote turning off, the remote controller will automatically memorize the previous set swing position.
  • Page 15: Sleep Operation

    In COOL, DRY mode another 1 hours, temp. rises by 1 C further. The unit will run for further 6 hours then stops. Temp. is higher than temp. setting so that room temperature won't be too Iow for your sleep.
  • Page 16: Timer On/Off Operation

    After replacing batteries or a power failure happens, time setting should be reset. Remote controller possesses memory function, when use TIMER mode next time, just press SET button after mode selecting if time setting is the same as previous one.
  • Page 17 " on the remote controller stops flashing. " " starts flashing. Time displayed: Unit starts or stops at x hour x min. 5.Time setting for TIMER OFF Just press HOUR button ,follow the same procedure in "Time setting for TIMER ON"...
  • Page 18: Health Airflow Operation

    2).Press the button of health airflow again, appears on the display. The above inlet and outlet grills of the air cond- itioner are closed and the airflow is blown vertically from the FRESH nether inlet and outlet grills. Avoid the strong airflow blows direct to the body.
  • Page 19: Emergency And Test Operation

    Removal of the restriction of emergency or test operation Press the emergency operation switch once more, or manipulate through the remote controller; the "Pi" sound, the emergency or test operation is terminated. When the remote controller is manipulated, it gets the system back to the normal operation mode.
  • Page 20: Maintenance

    Use the timer effectively during operation During cooling operation prevent the penetration of direct sunlight with curtain or blind Use the louvers effectively If the unit is not to be used for a long time, turn off the power supply main switch.
  • Page 21: Air Filter Cleaning

    Maintenance For Smart Use of The Air Conditioner WARNING Before maintenance,be sure to turn off the system and the circuit breaker. Remote Controller Indoor Body Wipe the air conditioner by using a soft and dry cloth.For serious stains,use a neutral detergent diluted with water.Wring the water...
  • Page 22 The photocatalyst air purifying filter will be solarized in fixed time. In normal family, it will be solarized every 6 months. The solarization time will last no less than 8 hours under the state of abundant sun.
  • Page 23: Cleaning The Body

    To Keep Your Air conditioner in Good Condition after Season. Operate in cooling mode for 2-3 hours. To prevent breeding mold or bad smell, be sure to operate at the designated temperature or 30 C,cooling mode and High speed fan mode for 2-3 hours.
  • Page 24: Connecting The Earthing Cable

    Before Setting in High season Cleaning the standard air filter. Operation without filter may cause troubles.Be sure to attach both right and left filters prior to the operation. Each of them are of different shapes. Connecting the earthing cable. Caution Incomplete earthing may cause an electric shock.
  • Page 25: Troubleshooting

    This noise is generated by the inspection casing expanding or shrinking because of temperature changes. Should there be a big noise from air flow in unit operation, air filter may be too dirty. This is because the system circulates smells Smells are generated.