Page 3
Thermographic Cube Camera User Manual DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES.
Page 4
Thermographic Cube Camera User Manual Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Indicates a hazardous situation which, if not avoided, will or could Danger result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could Caution result in equipment damage, data loss, performance degradation, or...
Page 5
Thermographic Cube Camera User Manual Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. Laws and Regulations In the use of the product, you must be in strict compliance with the electrical safety regulations ●...
Page 6
Thermographic Cube Camera User Manual Please purchase the charger by yourself. Input voltage should meet the Limited Power Source ● (12 VDC) according to the IEC62368 standard. Please refer to technical specifications for detailed information. Make sure the plug is properly connected to the power socket. ●...
Page 7
Thermographic Cube Camera User Manual The interface varies with the models. Please refer to the product datasheet for details. ● If the device needs to be wired by yourself, select the corresponding wire to supply power ● according to the electric parameters labeled on the device. Strip off wire with a standard wire stripper at corresponding position.
Page 8
Thermographic Cube Camera User Manual The openings shall never be blocked by placing the device on a bed, sofa, rug, or other similar surface. Keep a proper distance around the device for sufficient ventilation. ● This device is suitable for mounting on concrete or other non-combustible surface only to avoid ●...
Thermographic Cube Camera User Manual Contents Chapter 1 Overview ........................1 1.1 Brief Description ........................1 1.2 Function ..........................1 Chapter 2 Device Activation and Accessing ................. 2 2.1 Activate the Device via HIKMICRO Studio ................2 2.2 Activate the Device via Browser ..................... 2 2.3 Login ............................
Page 11
Thermographic Cube Camera User Manual 7.1.9 Display VCA Info ......................29 7.1.10 Set ROI ........................29 7.1.11 Metadata ........................30 7.2 Display Settings ........................30 7.2.1 Image Adjustment ....................... 30 7.2.2 Image Adjustment (Thermal Channel) ................ 30 7.2.3 Exposure Settings ......................31 7.2.4 Day/Night Switch ......................
Page 12
Thermographic Cube Camera User Manual 8.1.1 Set Memory Card ......................38 8.1.2 Set NAS ........................38 8.1.3 Set FTP ........................39 8.1.4 Set Cloud Storage ......................39 8.2 Video Recording ........................40 8.2.1 Record Automatically ....................40 8.2.2 Playback and Download Video ..................42 8.2.3 Record Manually ......................
Page 13
Thermographic Cube Camera User Manual 9.10 Set Open Network Video Interface ..................53 9.11 Set Alarm Server ........................ 53 9.12 Set SRTP ..........................54 9.13 Set Network Service ......................54 9.14 Modbus Communication ....................54 9.14.1 Set Modbus Main Mode ................... 55 9.14.2 Set Modbus Subordinate Mode ................
Page 14
Thermographic Cube Camera User Manual 10.13.4 Certificate Management ..................65 10.13.5 Control Timeout Settings ..................68 10.13.6 Set HTTPS ........................ 68 10.13.7 Set IEEE 802.1X ....................... 68 10.13.8 Set QoS ........................68 10.14 User and Account ......................69 10.14.1 Set User Account and Permission ................69 10.14.2 Online Users ......................
Thermographic Cube Camera User Manual Chapter 1 Overview 1.1 Brief Description The Thermographic Cube Camera is a temperature measurement device which is equipped with a thermal lens. It is equipped with high-sensitivity IR detector and high-performance sensor. The device is able to measure object's temperature at a high accuracy in real time.
Thermographic Cube Camera User Manual Chapter 2 Device Activation and Accessing To protect the security and privacy of the user account and data, you should set a login password to activate the device when access the device via network. Note Refer to the user manual of the software client for the detailed information about the client software activation.
Thermographic Cube Camera User Manual Steps 1. Connect the device to the PC using the network cables. 2. Change the IP address of the PC and device to the same segment. Note The default IP address of the device is 192.168.1.64. You can set the IP address of the PC from 192.168.1.2 to 192.168.1.253 (except 192.168.1.64).
Thermographic Cube Camera User Manual Operating System Web Browser Operation WebSocket or WebSockets for normal view if plug-in installation is not required. Display and operation of certain functions are restricted. For example, Playback and Picture are not available. For detailed restricted function, refer to the actual device.
Thermographic Cube Camera User Manual Chapter 3 Temperature Measurement When you enable this function, the device measures the actual temperature of the scene. It alarms when temperature exceeds the temperature threshold value. 3.1 Notice This part introduces the notices of configuring temperature measurement function. The target surface should be as vertical to the optical axis as possible.
Thermographic Cube Camera User Manual Figure 3-1 Thermometry Flow Chart 3.3 Automatic Thermography Configure the temperature measurement parameters and temperature measurement rules. The device can measure the actual temperature and output alarms when temperature exceeds the alarm threshold value.
Thermographic Cube Camera User Manual 3.3.1 Set Thermometry Parameters Configure the parameters of temperature measurement. Steps 1. Go to Configuration → Local , enable Display Temperature Info. . Display Temperature Info. Select Yes to display temperature information on live view. Enable Rules to display the rules information on live view.
Thermographic Cube Camera User Manual Select the desired alarm mode. In temperature measurement alarm mode, the device outputs alarm if the detected temperature is higher than the alarm threshold. In interval temperature measurement alarm mode, the device outputs alarm if the detected temperature is within the set temperature range.
Page 23
Thermographic Cube Camera User Manual Note Select Alarm Mode as Temperature Measurement Alarm first in basic settings. Emissivity Set the emissivity of your target. The emissivity of each object is different. Distance The distance between the target and the device. Pre-Alarm Temperature When the temperature of target exceeds the pre-alarm threshold, and this status keeps more than Filtering Time, it triggers pre-alarm.
Thermographic Cube Camera User Manual Edit the interval name. Temperature Range The device outputs an alarm if the detected temperature is within the set temperature range. Alarm Rule Color Set the rule color in alarm status. Alarm Output Select the alarm output channel. 5.
Thermographic Cube Camera User Manual 3.3.4 Set Thermography Rule Steps 1. Customize the rule name. 2. Select the rule type to Point, Line, or Area. Then draw a point, line, or area on the interface where the position to be measured. Point Please refer to Point Thermography for detailed configuration.
Page 26
Thermographic Cube Camera User Manual Line Thermography Configure the temperature measurement rule and monitor the maximum temperature of the line. Steps 1. Click and drag the mouse to draw a line in the live view interface. 2. Click and move the line to adjust the position. 3.
Page 27
Thermographic Cube Camera User Manual Set the tolerance temperature to prevent the constant temperature change to affect the alarm. E.g., set tolerance temperature as 3°C, set alarm temperature as 55°C, and set pre- alarm temperature as 50°C. The device sends pre-alarm when its temperature reaches 50°C and it alarms when its temperature reaches 55°C and only when the device temperature is lower than 52°C will the alarm be cancelled.
Thermographic Cube Camera User Manual 6. Select the alarm output channel. Note The function varies according to different models. 3.4 Manual Thermography After enable the manual thermography function of the device, you can click any position on the live view to show the real temperature. Steps 1.
Thermographic Cube Camera User Manual Data Length It stands for the data length of the detected temperature information of every pixel. 2 means the temperature information type of every pixel is "short", and 4 means the type is "float". Max. Frame Rate The max.
Thermographic Cube Camera User Manual Chapter 4 Event and Alarm This part introduces the configuration of events. The device takes certain response to triggered alarm. Certain events may not be supported by certain device models. 4.1 Set Video Tampering Alarm When the configured area is covered and cannot be monitored normally, the alarm is triggered and the device takes certain alarm response actions.
Thermographic Cube Camera User Manual Figure 4-1 Set Video Tampering Area 6. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for setting linkage method. 7. Click Save. 4.2 Set Alarm Input Alarm signal from the external device triggers the corresponding actions of the current device. Before You Start Make sure the external alarm device is connected.
Thermographic Cube Camera User Manual 4. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for setting linkage method. 5. Click Copy to... to copy the settings to other alarm input channels. 6. Click Save. 4.3 Set Exception Alarm Exception such as network disconnection can trigger the device to take corresponding action.
Thermographic Cube Camera User Manual Chapter 5 Arming Schedule and Alarm Linkage Arming schedule is a customized time period in which the device performs certain tasks. Alarm linkage is the response to the detected certain incident or target during the scheduled time. 5.1 Set Arming Schedule Set the valid time of the device tasks.
Thermographic Cube Camera User Manual Automatic Alarm Set the automatic alarm parameters, then the device triggers an alarm output automatically in the set arming schedule. Steps 1. Set automatic alarm parameters. Alarm Output No. Select the alarm output No. according to the alarm interface connected to the external alarm device.
Thermographic Cube Camera User Manual Refer to Set FTP to set the FTP server. Refer to Set NAS for NAS configuration. Refer to Set Memory Card for memory card storage configuration. 5.2.3 Send Email Check Send Email, and the device sends an email to the designated addresses with alarm information when an alarm event is detected.
Thermographic Cube Camera User Manual 5.2.4 Notify Surveillance Center Check Notify Surveillance Center, the alarm information is uploaded to the surveillance center when an alarm event is detected. 5.2.5 Trigger Recording The video will be recorded when the configured action/event is detected. Related recording settings should be done in advance.
Thermographic Cube Camera User Manual Chapter 6 Live View It introduces the live view parameters, function icons and transmission parameters settings. 6.1 Live View Parameters The supported functions vary depending on the model. Note For multichannel devices, select the desired channel first before live view settings. 6.1.1 Window Proportion refers to the window size is 16 : 9.
Thermographic Cube Camera User Manual 6.2 View Previous/Next Page When the number of channels surpasses that of live view window division, this function can switch live view among multiple channels. Click to switch live view among multiple channels. 6.3 Full Screen This function is used to view the image in full screen mode.
Page 39
Thermographic Cube Camera User Manual UDP is suitable for the unstable network environment that does not demand high video fluency. MULTICAST MULTICAST is suitable for the situation that there are multiple clients. You should set the multicast address for them before selection. HTTP HTTP is suitable for the situation that the third-party needs to get the stream from the device.
Thermographic Cube Camera User Manual Chapter 7 Video and Audio This part introduces the configuration of video and audio related parameters. 7.1 Video Settings This part introduces the settings of video parameters, such as, stream type, video encoding, and resolution. Go to setting page: Configuration →...
Thermographic Cube Camera User Manual 7.1.4 Bitrate Type and Max. Bitrate Constant Bitrate It means that the stream is compressed and transmitted at a comparatively fixed bitrate. The compression speed is fast, but mosaic may occur on the image. Variable Bitrate It means that the device automatically adjust the bitrate under the set Max.
Thermographic Cube Camera User Manual H.265 H.265, also known as High Efficiency Video Coding (HEVC) and MPEG-H Part 2, is a compression standard. In comparison to H.264, it offers better video compression at the same resolution, frame rate and image quality. Profile This function means that under the same bitrate, the more complex the profile is, the higher the quality of the image is, and the requirement for network bandwidth is also higher.
Thermographic Cube Camera User Manual 7.1.9 Display VCA Info VCA information can be displayed by Player and Video. Player Player means the VCA info can be displayed by the dedicated player provided by the manufacturer. Video Video means the VCA info can be displayed by any general video player. 7.1.10 Set ROI ROI (Region of Interest) encoding helps to assign more encoding resource to the region of interest, thus to increase the quality of the ROI whereas the background information is less focused.
Thermographic Cube Camera User Manual 7.1.11 Metadata Metadata is the raw data that the device collects before algorithm processing. It is often used for the third party integration. Go to Configuration → Video/Audio → Metadata Settings to enable metadata uploading of the desired function for the camera channels.
Thermographic Cube Camera User Manual Histogram: Choose for scene with obvious WDR and high temperature difference, can ● improve image contrast and enhance image. E.g. the scene contains both indoor and outdoor scenes. Linear: Choose for scene with low temperature difference and the target is not obvious, can ●...
Thermographic Cube Camera User Manual This feature uses smart image processing technology to reduce overexposure caused by supplement light. Smart Supplement Light Mode Enable or disable the smart supplement light. Brightness Limit Adjust the upper limit of supplement light power. Light Brightness Control Manual You can drag the slider or set value to adjust the brightness.
Thermographic Cube Camera User Manual Set the DNR level to control the noise reduction degree. The higher level means stronger reduction degree. Expert Set the DNR level for both space DNR and time DNR to control the noise reduction degree. The higher level means stronger reduction degree.
Thermographic Cube Camera User Manual 7.2.11 Set Target Enhancement You can set the color of the targets in different temperature ranges to identify the target quickly. Steps 1. Go to Configuration → Image → Display Settings . 2. Select the thermal channel. 3.
Thermographic Cube Camera User Manual Note The video recording will be shortly interrupted when the function is enabled. 7.2.14 Video Standard Video standard is an ability of a video card or video display device that defines the amount of colors that are shown and the resolution. The two most common video standard used are NTSC and PAL.
Thermographic Cube Camera User Manual OSD Parameters Set OSD parameters, such as Display Mode, OSD Size, Font Color, and Alignment. 7.4 Set Privacy Mask The function blocks certain areas in the live view to protect privacy. No matter how the device moves, the blocked scene will never be seen.
Thermographic Cube Camera User Manual Steps 1. Select a channel number. 2. Select the picture in picture mode. Normal Mode Disable picture in picture mode. Details Overlay Enable picture in picture mode. You can overlay the image of another Mode channel in the current channel.
Thermographic Cube Camera User Manual Chapter 8 Video Recording and Picture Capture This part introduces the operations of capturing video clips and snapshots, playback, and downloading captured files. 8.1 Storage Settings This part introduces the configuration of several common storage paths. 8.1.1 Set Memory Card If you choose to store the files to memory card, make sure you insert and format the memory card in advance.
Thermographic Cube Camera User Manual The saving path of network disk files. Mounting Type Select file system protocol according to the operation system. Enter user name and password of the net HDD to guarantee the security if SMB/CIFS is selected. 3.
Thermographic Cube Camera User Manual 1. Go to Configuration → Storage → Storage Management → Cloud Storage . 2. Check Enable Cloud Storage. 3. Set basic parameters. Protocol Version The protocol version of the cloud video manager. Server IP The IP address of the cloud video manager. It supports IPv4 address. Serve Port The port of the cloud video manager.
Page 55
Thermographic Cube Camera User Manual Note The record type is vary according to different models. Continuous The video will be recorded continuously according to the schedule. Motion When motion detection is enabled and trigger recording is selected as linkage method, object movement is recorded.
Thermographic Cube Camera User Manual The recordings are deleted when they exceed the expired time. The expired time is configurable. Note that once the recordings are deleted, they can not be recovered. 7. Click Save. 8.2.2 Playback and Download Video You can search, playback and download the videos stored in the local storage or network storage.
Thermographic Cube Camera User Manual 8.3.1 Capture Automatically This function can capture pictures automatically during configured time periods. Steps 1. Go to Configuration → Storage → Schedule Settings → Capture → Capture Parameters . 2. Select a channel to set capture parameters. 3.
Page 58
Thermographic Cube Camera User Manual Note Go to Configuration → Local , click Save snapshots when playback to change the saving path of pictures.
Thermographic Cube Camera User Manual Chapter 9 Network Settings 9.1 TCP/IP TCP/IP settings must be properly configured before you operate the device over network. IPv4 and IPv6 are both supported. Both versions can be configured simultaneously without conflicting to each other. Go to Configuration →...
Thermographic Cube Camera User Manual Input IPv6 Address, IPv6 Subnet, IPv6 Default Gateway. Consult the network administrator for required information. It stands for maximum transmission unit. It is the size of the largest protocol data unit that can be communicated in a single network layer transaction. The valid value range of MTU is 1280 to 1500.
Thermographic Cube Camera User Manual It refers to the port through which the browser accesses the device with certificate. Certificate verification is required to ensure the secure access. Server Port It refers to the port through which the client adds the device. WebSocket Port TCP-based full-duplex communication protocol port for plug-in free preview.
Thermographic Cube Camera User Manual 9.3.2 Set Manual Port Mapping Steps 1. Check Enable UPnP™, and choose a friendly name for the device, or you can use the default name. 2. Select the port mapping mode to Manual, and set the external port to be the same as the internal port.
Thermographic Cube Camera User Manual Figure 9-1 Port Mapping on Router Note The port of the network camera cannot conflict with other ports. For example, some web management port of the router is 80. Change the camera port if it is the same as the management port.
Thermographic Cube Camera User Manual 9.5 SNMP You can set the SNMP network management protocol to get the alarm event and exception messages in network transmission. Before You Start Before setting the SNMP, you should download the SNMP software and manage to receive the device information via SNMP port.
Thermographic Cube Camera User Manual By Client Software Add domain name to the client software. Refer to the client manual for specific adding methods. 9.7 Access to Device via PPPoE Dial Up Connection This device supports the PPPoE auto dial-up function. The device gets a public IP address by ADSL dial-up after the device is connected to a modem.
Thermographic Cube Camera User Manual 9.8.1 Enable Hik-Connect Service via Web Browser Follow the following steps to enable Hik-Connect Service via Web Browser. Before You Start You need to activate the camera before enabling the service. Steps 1. Access the camera via web browser. 2.
Thermographic Cube Camera User Manual Steps 1. Go to Configuration → Network → Advanced Settings → Platform Access . 2. Select ISUP as the platform access mode. 3. Select Enable. 4. Select a protocol version and input related parameters. 5. Click Save. Register status turns to Online when the function is correctly set.
Thermographic Cube Camera User Manual 9.12 Set SRTP The Secure Real-time Transport Protocol (SRTP) is a Real-time Transport Protocol (RTP) internet protocol, intended to provide encryption, message authentication and integrity, and replay attack protection to the RTP data in both unicast and multicast applications. Steps 1.
Thermographic Cube Camera User Manual data, or responding to temperature measurement parameter configuration requests from the main. Please select the device mode and configure the communication rules and parameters according to the demand to ensure the security of data transmission under the premise of satisfying the data access of the device.
Page 70
Thermographic Cube Camera User Manual TCP type, but the IP/decoding address and port of the TCP connection cannot be duplicated. RS-485 Before selecting an RS-485 connection, make sure that the connection between the device and the subordinate has been established through the RS-485 connector on the body. And only 1 RS-485 connection can be supported.
Thermographic Cube Camera User Manual Figure 9-3 Register Configuration 7. Click Save. 9.14.2 Set Modbus Subordinate Mode Configure the device as the subordinate server, the main can read the temperature measurement data of the device or write the temperature measurement parameters of the device. The form of authorized access can improve data communication security.
Thermographic Cube Camera User Manual 3. Check Enable Authorized IP Addresses and click Add to add IP addresses that are allowed to access to the device. Note With regard to the network security risk, it is recommended to limit permission only to trusted IP addresses.
Page 73
Thermographic Cube Camera User Manual Error Code Name Description as that the implied length is incorrect. It specifically does NOT mean that a data item submitted for storage in a register has a value outside the expectation of the application program, since the Modbus protocol is unaware of the significance of any particular value of any particular register.
Thermographic Cube Camera User Manual Chapter 10 System and Security It introduces system maintenance, system settings and security management, and explains how to configure relevant parameters. 10.1 View Device Information You can view device information, such as Device No., Model, Serial No. and Firmware Version. Enter Configuration →...
Thermographic Cube Camera User Manual 10.4 Export Diagnose Information Diagnose information includes running log, system information, hardware information. Go to Configuration → System → Maintenance → Upgrade & Maintenance , and click Diagnose Information to export diagnose information of the device. 10.5 Reboot You can reboot the device via browser.
Thermographic Cube Camera User Manual Firmware Directory Locate the directory which the upgrade file belongs to. 3. Click Browse to select the upgrade file. 4. Click Upgrade. 10.8 View Open Source Software License Go to Configuration → System → System Settings → About , and click View Licenses. 10.9 Time and Date You can configure time and date of the device by configuring time zone, time synchronization and Daylight Saving Time (DST).
Thermographic Cube Camera User Manual 6. Click Save. 10.9.3 Set DST If the region where the device is located adopts Daylight Saving Time (DST), you can set this function. Steps 1. Go to Configuration → System → System Settings → DST . 2.
Thermographic Cube Camera User Manual 10.12 Set Same Unit Set the same temperature unit and distance unit. When you enable this function, the unit cannot be configured separately in other setting pages Steps 1. Go to Configuration → System → System Settings → Unit Settings . 2.
Thermographic Cube Camera User Manual Search Security Audit Logs You can search and analyze the security log files of the device so as to find out the illegal intrusion and troubleshoot the security events. Steps Note This function is only supported by certain camera models. 1.
Page 80
Thermographic Cube Camera User Manual Note The function is only supported by certain device models. Create Self-signed Certificate Steps 1. Click Create Self-signed Certificate. 2. Follow the prompt to enter Certificate ID, Country/Region, Hostname/IP, Validity and other parameters. Note The certificate ID should be digits or letters and be no more than 64 characters. 3.
Page 81
Thermographic Cube Camera User Manual Note Up to 16 certificates are allowed. ● If certain functions are using the certificate, it cannot be deleted. ● You can view the functions that are using the certificate in the functions column. ● You cannot create a certificate that has the same ID with that of the existing certificate and ●...
Thermographic Cube Camera User Manual 10.13.5 Control Timeout Settings If this function is enabled, you will be logged out when you make no operation (not including viewing live image) to the device via web browser within the set timeout period. Go to Configuration →...
Thermographic Cube Camera User Manual Note QoS needs support from network device such as router and switch. Steps 1. Go to Configuration → Network → Advanced Configuration → QoS . 2. Set Video/Audio DSCP, Alarm DSCP and Management DSCP. Note Network can identify the priority of data transmission.
Thermographic Cube Camera User Manual Delete Select a user and click Delete. Note The administrator can add up to 31 user accounts. 3. Click OK. 10.14.2 Online Users The information of users logging into the device is shown. Go to Configuration → System → User Management → Online Users to view the list of online users.
Need help?
Do you have a question about the HM-TD3028T-3/Q(B) and is the answer not in the manual?
Questions and answers