Operating and Installation
Instructions Display Unit
KERN KMC-TM
Version 1.0
06/2013
GB
KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
E-Mail: info@kern-sohn.com
Phone: +49-[0]7433- 9933-0
Fax: +49-[0]7433-9933-149
Internet: www.kern-sohn.com
KMC-TM-BA_IA-e-1310

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KMC-TM and is the answer not in the manual?

Questions and answers

Summary of Contents for KERN KMC-TM

  • Page 1 KERN & Sohn GmbH Ziegelei 1 Phone: +49-[0]7433- 9933-0 D-72336 Balingen Fax: +49-[0]7433-9933-149 E-Mail: info@kern-sohn.com Internet: www.kern-sohn.com Operating and Installation Instructions Display Unit KERN KMC-TM Version 1.0 06/2013 KMC-TM-BA_IA-e-1310...
  • Page 2: Table Of Contents

    KERN KMC-TM Version 1.0 06/2013 Operating and installation instructions Display unit Contents Technical data ....................4 Appliance overview ..................5 Overview of display ....................6 Keyboard overview ....................7 Basic instructions ..................8 Proper use ......................... 8 Improper Use ......................8 Warranty ........................
  • Page 3 How to connect the platform ..................22 11.4 Configure display unit ....................23 11.4.1 Navigation in the menu ......................23 11.4.2 Menu overview ........................24 Verification ....................27 Adjustment ....................29 Enclosure Type Approval Certificate when using as weighing system KERN MBC 31 KMC-TM-BA_IA-e-1310...
  • Page 4: Technical Data

    Power pack secondary voltage 12V, 500mA Dimensions 195 x 118 x 83 (B x D x H) mm Admissible -10°C – 40°C ambient temperature Net weight 1 kg Medical product in accordance with Class I when using as weighing system KERN MBC 93/42/EEC KMC-TM-BA_IA-e-1310...
  • Page 5: Appliance Overview

    2 Appliance overview 1. Weight display 2. Battery charge status 3. Keyboard 4. Weighing unit 5. Adjustment switch 6. Terminal power supply unit 7. Connection connecting cable „display unit - loading cell" 8. Battery compartment KMC-TM-BA_IA-e-1310...
  • Page 6: Overview Of Display

    HOLD function active DRINK DRINK function Is illuminated with active drink function Rechargeable battery Lights when the voltage drops below the symbol prescribed minimum. Lights when the rechargeable battery capacity is almost exhausted. Lights when the rechargeable battery is fully charged. KMC-TM-BA_IA-e-1310...
  • Page 7: Keyboard Overview

    Select menu items For numeric entry: Edit numeric value The gross weight of the baby after drinking is is displayed. In menu:  Confirm selection For numeric entry:  Confirm numerical value HOLD button Hold function ON/OFF Turn on/off button KMC-TM-BA_IA-e-1310...
  • Page 8: Basic Instructions

    The display unit may only be operated in accordance with the described default settings. Other areas of use must be released by KERN in writing. 3.3 Warranty Warranty claims shall be voided in case •...
  • Page 9: Monitoring Of Test Resources

    KERN’s home page (www.kern-sohn.com with regard to the monitoring of display units’ test substances and the test weights required for this. In KERN’s accredited DKD calibration laboratory test weights and display units may be calibrated (return to the national standard) fast and at moderate cost.
  • Page 10: Unpacking, Setup And Commissioning

    6.2 Unpacking Carefully remove the display unit from packaging, remove plastic cover and place it in the designated work area. 6.3 Scope of delivery  Display Unit  Mains adapter (in conformity with EN 60601-1)  Operating instructions KMC-TM-BA_IA-e-1310...
  • Page 11: Mains Connection

    Power is supplied via the external mains adapter. The stated voltage value must be the same as the local voltage. Only use original KERN mains adapters as per EN 60601-1. The small sticker attached to the side of the display unit indicates the power port: The LED remains illuminated as long as the weighing scale remains connected to the mains.
  • Page 12: Battery Operation Is Possible By Obtaining An Optional Battery Power Pack

    (mains, accumulator or battery) and be switched on. The accuracy of the balance depends on the local acceleration of gravity. The value of gravity acceleration is shown on the type plate. KMC-TM-BA_IA-e-1310...
  • Page 13: Operation

    Wait until the standstill display „STABLE“ appears, then read the weighing result.  When the balance is unloaded the saved taring value is displayed with negative sign.  To delete the tare value, remove load from balance and press KMC-TM-BA_IA-e-1310...
  • Page 14: Data-Hold Function

     Place goods to be weighed on balance. After standstill control there sounds an acoustic signal, the weight value will be displayed. After unloading the balance, the weighing value remains displayed for approx. 10 seconds, than the balance changes automatically into the weighing mode. The „HOLD“ symbol disappears. KMC-TM-BA_IA-e-1310...
  • Page 15: Feeding Function (Control Of Weight Gain)

     Return to weighing mode using 7.8 See second decimal point (not verified value) Press and hold for about 2 s whilst weighed result is being shown. The second decimal place will be shown for approx. 5 s. KMC-TM-BA_IA-e-1310...
  • Page 16: Automatic Switch-Off Function „Auto Off

    AUTO-OFF after 5 minutes without changing the weight [oFF 15] AUTO-OFF after 15 minutes without changing the weight [oFF 30] AUTO-OFF after 30 minutes without changing the weight  Confirm with , [F1 oFF] will be displayed  Return to weighing mode using KMC-TM-BA_IA-e-1310...
  • Page 17: Display Background Illumination

    Continuous background lighting bL off Background illumination off bL AU Automatic background illumination on when weighing surface is loaded or key pressed.  Confirm with , [F2 bk] will be displayed.  Return to weighing mode using KMC-TM-BA_IA-e-1310...
  • Page 18: Error Messages

    • Incorrect adjusting process • Fault on load cell Value outside the A/D converter range • Damaged weighing cell • Damaged electronics Should other error messages occur, switch weighing system off and then on again. If the error message remains inform manufacturer. KMC-TM-BA_IA-e-1310...
  • Page 19: Servicing, Maintenance, Disposal

     Do not use aggressive detergents (solvents or similar). 9.2 Servicing, maintenance The appliance may only be opened by trained service technicians who are authorized by KERN. Disconnect the device from mains before opening. 9.3 Disposal Disposal of packaging and appliance must be carried out by operator according to valid national or regional law of the location where the appliance is used.
  • Page 20: Instant Help

     Weighing system is not levelled.  Electromagnetic fields / static charging (choose different location/switch off interfering device if possible) Should other error messages occur, switch balance off and then on again. If the error message remains inform manufacturer. KMC-TM-BA_IA-e-1310...
  • Page 21: Installation Display Unit

    The addition of weighing scales capacity, preload and the total zero setting range give the required capacity for the weighing cell. To avoid overloading of the weighing cell, include an additional safety margin. • Smallest desired display division • Verifiable, if required KMC-TM-BA_IA-e-1310...
  • Page 22: How To Connect The Platform

    11.3 How to connect the platform  Disconnect the display unit from the power supply.  Solder the individual leads of the load cell cable onto the circuit board, see diagrams below. Weighing cell (Zemic L6D) Display Unit KERN KMC-TM KMC-TM-BA_IA-e-1310...
  • Page 23: Configure Display Unit

    Numeric entry  Use to select the digit to be changed, the active digit flashes.  Use to increase numeric value.  Acknowledge by Exit menu/  Press , the balance will return to weighing mode. Return to weighing mode KMC-TM-BA_IA-e-1310...
  • Page 24: Menu Overview

    Backlighting for display will come on automatically as soon as the weighing scale is operated. If display shows "Pin" actuate adjustment switch. Service menu Then press subsequently. P1 Spd SPd 7.5 Display speed SPd 15* Not documented SPd 30 SPd 60 KMC-TM-BA_IA-e-1310...
  • Page 25 5 2. Weighing range div 10 Selectable 1, 2, 5, 10, 20, div 20 div 50 Balance capacity (Max) 1st weighing range Balance capacity (Max) 2nd weighing range Adjust weighing system after configuration. Adjustment, see chap. 13 KMC-TM-BA_IA-e-1310...
  • Page 26 Balance capacity (Max) 2nd weighing range Adjust weighing system according to configuration. Adjustment, see chap. 13 P3 Pro tri* Not documented CoUnt Internal A/D converter value rESEt Reset weighing scale to factory setting Not documented SEtGrA * default setting KMC-TM-BA_IA-e-1310...
  • Page 27: Verification

    The weighing result of the balance is outside the error limit. Therefore, • in regular intervals load balance with known test weight (ca. 1/3 of the max. load) and compare with displayed value. The reverification deadline has been exceeded. • KMC-TM-BA_IA-e-1310...
  • Page 28 Position adjustment switch and seals: Self-destroying seal mark Cover Adjustment switch KMC-TM-BA_IA-e-1310...
  • Page 29: Adjustment

    • Prepare the required adjustment weight. The weight to be used depends on the capacity of the scale. Carry out adjustment as near as possible to the scale’s maximum weight. Info about test weights can be found on the Internet at: http://www.kern-sohn.com. • Observe stable environmental conditions. Stabilisation requires a certain warm-up time.
  • Page 30 SnGrA = Single-range balance dUArG = Dual range balance dUA in = Multi interval balance   To change select scale type with and confirm with [dESC] appears.  Press repeatedly until [CAL] will be displayed.  Confirm with , [UnloAd] appears KMC-TM-BA_IA-e-1310...
  • Page 31: Enclosure

    An adjusting error or incorrect adjusting weight will be indicated by the error message; repeat adjustment procedure. An adjusting error or incorrect adjustment weight will generate an error message („Err 4“), repeat the adjustment process. 14 Enclosure Type Approval Certificate when using as weighing system KERN KMC-TM-BA_IA-e-1310...