Page 1
SL-155 Series SL-155-5D/10D Models Marine Lanterns INSTALLATION & SERVICE MANUAL V2.7...
Page 2
Version No. Description Date Approved Manual Launch June 2014 Y. Chambers Manual Update August 2014 Y. Chambers Spec Update March 2015 J. Dore Separate Manual. Power consumption & Power June 2015 Y. Chambers supply design considerations added. Intensity update July 2015 D.
Precision Construction Commitment to investing in the design and construction of injection-moulded parts including optic lenses, light bases and a range of other components ensures that all Sealite products are of a consistent & superior quality. Optical Performance Sealite manufactures a range of marine LED lenses moulded from multi-cavity dies. The company has superior in-house lens manufacturing capabilities to support outstanding optical performance.
System status includes battery condition, flash characters, operational configuration, and lantern/buoy position. Integrated bird deterrent UV-stabilised acrylic lens LED Optic 7-stage powder coated aluminium base 200mm bolt pattern for ease of installation 5 degree/10 degree model Latest products and information available at www.sealite.com...
Page 7
IALA Signal colours compliant to IALA E-200-1 Quality Assurance ISO9001:2015 Intellectual Property Trademarks SEALITE is a registered trademark of Sealite Pty Ltd ® Warranty * 3 years Options Available • GPS Synchronisation • AIS Type 1 or Type 3 • GSM Monitoring & Control System •...
Serial Port to USB cable may need to be purchased. Please check that ALL of these components are included with your order, and contact your Sealite representative as soon as possible if anything is missing.
(as supplied on USB drive with every lantern). To change/update the settings of your lantern, please read the following instructions. Image 1. Sealite PC Configuration Tool Latest products and information available at www.sealite.com...
Page 10
You may wish to view these documents to read more about the innovative features and benefits of the SL-155 Series of lanterns. IMPORTANT: the Sealite PC Configuration Tool is designed for Windows Platforms only. 2. Connect the SL-155 Series Lantern to a Power Source & the Computer Now that the programming software has been run, you will need to connect the lantern to your computer &...
Page 11
Serial Port to USB cable may need to be purchased. 3. Establish the Programmer-to-Lantern Computer Connection (COM Port) Now that the lantern is connected to the computer and the Sealite PC Configuration software has been run, the user must create the programmer-to-lantern connection.
Page 12
Image 3. Sealite Configuration Tool “Info” tab – showing COM Port connection established, Version & Lantern Summary information...
Displays the alarm events recorded by the lantern firmware. Possible alarms (flat battery, low battery, LED failure, high temperature). All alarm events are recorded irrespective of whether the lantern has been configured to respond to an alarm. Latest products and information available at www.sealite.com...
Operation mode Tab Defines the lanterns mode of operation of which there are four possibilities: Operational Mode Standby The lantern is configured in a minimum current state in which the LEDs are always off and the internal GPS (if installed) is disabled. Always On The daylight sensor is disabled and the lantern operates according to the set flash character and intensity levels.
Page 15
Adjacent LED, alternate their on/off state based upon the intensity and flash character settings. For example, ship wreck marks. Note: This will be preset if you have ordered an emergency wreck mark. Reset By clicking Reset, the factory set default parameters are restored. Latest products and information available at www.sealite.com...
The flash character is defined by first selecting the Mariner code, then the Flash code name and finally timing. Sealite Code Selection This is an alternative method to define the lantern flash code by using the Sealite IR remote control numerical figure character. Refer to the IR remote control section for valid flash characters. Sync Offset This panel is used to set a fixed delay to the commencement of the flash character.
This intensity limit will not be reached for the majority of applications. The peak power limit for the SL-155-5D and SL-155-10D lanterns has been set to 28.125%. There are 69 flash codes in the base table of 256 that will have an intensity cap.
Sensors Battery sensors The SL-155 series of lantern continuously monitors its input voltage using three finable thresholds. • For voltages greater than “OK” level, the lantern reports via IR Remote control requests or the GSM that the input voltage is satisfactory. •...
Page 19
LUX. These levels can be customised by entering in separate dusk and dawn values as a measure of LUX. If optioned, an external light sensor such as Light dependant resistor or photodiode can be electrically connected to the SL-155. Latest products and information available at www.sealite.com...
AIS Report Lantern Status This panel displays the Lantern’s AIS message that is output via the serial communications port every 10 seconds. Typically this message is processed by an externally installed AIS module, however by itself is a quick summary of the lantern operating status. This detail is also displayed on the INFO tab.
Sealite IR Programmer / Universal Remote Compatibility If you lose your Sealite IR Programmer, the following Universal Remote Controller has been tested for compatibility: RCA Type RCR312WR programmed for Phillips TV Type Code 10054...
IR Programmer Functions Test Mode / Configure Pressing the T/C button for up to 5 seconds places the light in Test Mode. The light will flash once in response to the T/C button being pressed and then turn off. Normal Operation The light will return to normal operation once it has not detected a valid key press for 30 seconds.
The flash for number 0 is one long flash. For example if the current Flash Code is set to 51 via the AB Sealite Code, the lamp will flash number 081. For a flash code set to 01, the lamp will flash 001.
Battery Status This function reads the battery status. The response from the light is High Voltage: 4 flashes, Good Voltage: 3 flashes, Low Voltage 2 flashes, Cutoff Voltage or below: 1 flash. Example Key sequence: This key sets the ambient light threshold levels. The format is Where ‘x’...
The lamp can detect a change in switch settings if they are changed while the light is powered down. Example #2: The flash code is set according to the Sealite Code settings: A=5, B = 1. The operator changes the flash code to 65 (A=4, B=1) using the IR Remote Control. The new flash code is now configured to A=4, B=1.
Operational Mode (Advanced users) The lantern has three modes of operation: Always on, Standby Mode and Dusk-to-Dawn mode. These modes can be selected either via the IR remote control or via the GSM module (if fitted). In Always On mode, the daylight sensor is disabled and the lantern will remain ON. In Standby mode, the lantern is turned off and the daylight sensor is disabled.
Protected Earth Point , the negative power supply line (-VBATT) and power supply. Sealite recommends that installers perform a holistic review of the installation’s grounding paths, the lantern and its power supply paths with the purpose of dissipating electrostatic charge build up and eliminating grounding loops.
Note, this intensity limit will not be reached for the vast majority of applications. The Thermal Limit for the SL-155-5D and SL-155-10D Series lanterns has been set to 28.125%. The relationship between the Thermal Limit, Intensity and Flash Duty Cycle is illustrated in the...
Automatically the lantern calculates the MULTIPLIER and compares it to the maximum power Thermal limit. If the calculated value exceeds maximum power thermal limit, then the intensity is reduced to the highest intensity step to ensure that it is not exceeded. Latest products and information available at www.sealite.com...
Let’s try a practical example Case 1: SL-155-10D, White, 10NM, Flash Character Fl(3+1) 18s [1.5s on,1.5s off,1.5s on,1.5s off,1.5s on,4.5s off,1.5s on,4.5s off] 33.3% 1. Calculate the Flash Character Duty cycle (%) = (1.5+1.5+1.5+1.5)/(1.5+1.5+1.5+1.5+1.5+4.5+1.5+4.5)*100 = 33.3% 2. With a range of 10NM, use IALA E-200-2 and determine the Effective Intensity (cd) = 1,306cd 3.
Page 31
9. Using the Modified Allard method in reverse, the new Effective Intensity is = 1,224cd 10. Using IALA E-200-4, the new range is reduced to 9.8NM. (0.2NM less than desired range of 10MN) Latest products and information available at www.sealite.com...
However the vast majority of customer power supplies comprise of either Photovoltaic Power or AC Utility and as such this bulletin will focus on these types and how they apply to Sealite SL-155 and SL-300 long range lanterns.
Page 33
This is regardless of the lanterns set Flash Duty Cycle or Intensity Settings. Other considerations such as de-rating the AC/DC power supply due to environment and usage. Latest products and information available at www.sealite.com...
(Sealite recommend “Dusk to Dawn” mode). Lantern Installation The Sealite SL-155 may be installed with connection to mains power, or as a complete solar powered system (available from Sealite). IMPORTANT: the SL-155 must be installed appropriately where the lantern is not blocked by buildings, trees or other shadows that may affect the visibility of the lantern or the ambient light.
Page 35
6–13NM Marine Lanterns Option 2: Installation of Lantern to Solar Powered System Sealite has an optional complete solar powered system available to purchase with the standard SL- 155 lantern. Detailed instructions for installation of the solar system are listed as follows.
Page 36
Ref No. Description No. Required 140W Solar Panel & Frame Battery Box Cage Post, 150x150 minimum Client Supplied Steel Support Steel Brace Screw, 12mm x 75 Washer, 12mm Bolt, 10mm x 25 Washer, 10mm 2.10 Self Locking Nut, 10mm Alternative setup, using 2 x 85W panels.
Page 37
Join bullet connectors, red to red and blue to blue • Test the lantern. Cover the lantern completely to resemble night time. Allow 60 seconds for the lantern to activate • Uncover the lantern and it will turn off after 60 seconds Latest products and information available at www.sealite.com...
Page 38
Ref No. Description No. Required Battery Case, SPC353534 Battery, 12V 70AH or equivalent Bolt, battery Washer, battery Spring Washer, battery Nut, battery Figure 3. Battery and Battery Box...
Page 39
IMPORTANT: it is important to work with the team at Sealite when determining the quantity and size of both batteries and solar panels for this lantern. Duty cycle, intensity and local solar conditions are important factors to take into consideration when building a solar powered battery supply.
Optional GPS Synchronisation The lanterns can be fitted with a GPS module, and provide the user with the ability to install independently operating lanterns that all flash in synchronisation. No additional power supplies, aerials or control systems are required, and with its microprocessor- based system, the GPS option is specifically designed to provide maximum reliability and performance over a wide range of environmental conditions.
SMS text messages to designated cellular telephone numbers. Users can also have alarms and reports sent to designated email addresses. Please contact Sealite for further information and instructions. Latest products and information available at www.sealite.com...
Designed to be virtually maintenance-free, the SL-155 Series will require minimal attention. However, the following maintenance and servicing information is provided to help ensure the life of your Sealite product. 1. Cleaning Lens - occasional cleaning of the lantern lens may be required. Using a cloth and warm soapy water, wipe off any foreign matter before rinsing the lens with fresh water.
6–13NM Marine Lanterns Trouble Shooting Problem Remedy Unable to communicate with 1. Connect the USB drive provided by Sealite to the PC and open lantern via USB to view files. 2. Double-click on the file: ???Configx.xx.exe (note, version number may vary) 3.
Appendix Flash Codes Sealite marine lanterns may be set to any of 256 IALA recommended flash settings which are user-adjustable onsite without the need for external devices. SEALITE® code reference is listed by number of flashes For the latest version of this document visit www.sealite.com or email info@sealite.com...
Page 45
FL 15 S 14.0 FL 5 S LFL 15 S 11.0 FL 5 S OC 15 S FL 5 S FL 5 S LFL 20 S 18.0 FL 26 S 25.0 FL 5 S Latest products and information available at www.sealite.com...
Page 46
Sealite Code Controller Flash Code FL (2) 4 S VQ (2) 4 S FL (2) 4.5 S FL (2) 4.5 S FL (2) 4.5 S FL (2) 5 S FL (2) 5 S FL (2) 5 S FL (2) 5 S...
Page 47
FL (4) 20 S FL (4) 20 S 13.5 FL (4) 20 S 10.5 FL (4) 20 S Q (4) 20 S 16.5 Q (4) 28 S 24.5 FL (4) 30 S 26.5 Latest products and information available at www.sealite.com...
Page 48
Sealite Code Controller Flash Code Q (5) 7 S Q (5) 10 S FL (5) 12 S FL (5) 20 S 15.5 FL (5) 20 S 11.2 FL (5) 20 S 11.0 Sealite Code Controller Flash Code OFF ON OFF ON...
SL-155-5D/10D Models 6–13NM Marine Lanterns Notes Sealite LED Light Warranty Refer to Sealite website: sealite.com Latest products and information available at www.sealite.com...
Page 50
We believe technology improves navigation sealite.com info@sealite.com Sealite Pty Ltd Sealite Asia Pte Ltd Sealite United Kingdom Ltd Sealite USA LLC Australia Singapore +61 (0)3 5977 6128 +65 6908 2917 +44 (0) 1502 588026 +1 (603) 737 1311...
Need help?
Do you have a question about the SL-155-5D and is the answer not in the manual?
Questions and answers