Technical Specifications
Voltage: 380v / 3 Phase, 50 Hz (includes VFD
for 60 Hz operation)
Motor: 2 HP TEAO Fan
Weight: 90.7 kg / 200 lbs
Oscillation: 75° Vertical Cleaning Radius
Temp Rating: For use up to 75°C/170°F
Installation and electrical wiring must be completed by qualified persons in accordance with all applicable codes and standards.
Before servicing or cleaning the unit, disconnect the fan from the power supply and follow proper lock-out-tag-out procedures for your
location. Any cover, guard, or safety device removed for repair must be replaced as originally installed.
Ensure installation securement does not penetrate walls or ceilings where electrical components or wiring could be potentially damaged.
Fan units are not designed or intended to be mounted to movable objects.
All overhead areas must be cleaned and free of dust buildup prior to powering on fan. If fan is not in service, any dust buildup must be
cleaned prior to restarting fan.
SonicAire fans are for the prevention of dust accumulation and are not to be used for declassifying areas with dust accumulation.
1.336.712.2437
partsandservice@sonicaire.com

Table of Contents

WARNING
www.sonicaire.com
Original Instructions
Please read and save these instructions.
042321OI/XT205380v/B
2
2
3
7
7
8
8
9
10
11
12
14
16
19
21
22

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XT205 380v and is the answer not in the manual?

Questions and answers

Summary of Contents for SonicAire XT205 380v

  • Page 1: Table Of Contents

    All overhead areas must be cleaned and free of dust buildup prior to powering on fan. If fan is not in service, any dust buildup must be cleaned prior to restarting fan. SonicAire fans are for the prevention of dust accumulation and are not to be used for declassifying areas with dust accumulation. www.sonicaire.com 1.336.712.2437...
  • Page 2: Setting Up Your Fan

    Owner’s Manual Setting up your fan Your SonicAire XT205 380v fan comes completely assembled. The parts needed for installation are included in your package unless otherwise noted. If you have chosen additional accessories for your fan, please refer to the corresponding accessory manual for instructions regarding installation and operation.
  • Page 3: Installing Your Fan

    SonicAire XT205 (380v) Owner’s Manual Top View Front View Side View Figure 1.1 Pro100/200 Dimensions Installing your fan Please refer to the mount manual for specific instructions on attaching your fan to the building structure. This fan product manual assumes all mount installation instructions have been completed properly.
  • Page 4 SonicAire XT205 (380v) Owner’s Manual Figure 1.2 Complete hanging fan assembly Figure 1.3 Figure 1.4 Attach the free end of each safety cable to a secure building structure by using the included beam clamps and eye bolt Figure 1.4 or loop the cable around a secure beam.
  • Page 5 SonicAire XT205 (380v) Owner’s Manual Tighten the two cable clips on each cable securely and torque each nut evenly to 10 ft-lbs. Ensure that the saddle (not the U-bolt) of the cable clip is resting against the load bearing side of the cable.
  • Page 6 WILL CAUSE THE KEYS TO SHEAR AND CAN CAUSE POTENTIAL GEAR MOTOR FAILURE. WARRANTY DOES NOT COVER FAILURES ASSOCIATED WITH INCORRECT CONNECTING LINK PLACEMENT. PLEASE CONTACT SONICAIRE IF YOU HAVE ANY QUESTIONS REGARDING THE PROPER PLACEMENT OF THE CONNECTING LINK.
  • Page 7: Maintaining Your Fan

    ® Maintaining your fan Continuous operation SonicAire fans are designed so that they can operate continuously. In order for the fan to create an effective overhead barrier to prevent dust accumulation, the fan MUST be running during production. CAUTION: It is the customer’s responsibility to ensure that the fans are operated frequently enough that a “dust cloud”...
  • Page 8: Electrical Information

    Failure to use individual circuit protection will void the equipment warranty. The SonicAire fan motor is a three-phase 1.5kw/2 hp motor. The motor operates at 1725 rpm at 50 Hz. The indexing gear motor is a sealed three phase, 12W, 1/56 HP motor running at 0.7 RPM (at 50Hz).
  • Page 9: Fan Parts Warranty

    Parts and Service (partsandservice@sonicaire.com or 1-336-712-2437). You will be guided through some troubleshooting steps and offered the option to receive replacement parts or return the unit to the factory for repairs. SonicAire replacement parts carry a 1 year warranty. WHAT IS NOT COVERED Use in a manner that is inconsistent with SonicAire’s user, operator, or installation...
  • Page 10: Idrive

    Cosmetic damage including scratches, dents, chips, and other damage to the fan unit finishes, unless such damage results from defects in materials and workmanship and is reported to SonicAire within 45 days of shipment from factory. Discoloration, rust, or oxidation of surfaces resulting from caustic or corrosive environments including but not limited to high salt concentrations, high moisture or humidity, exposure to chemicals, or elevated ambient temperatures.
  • Page 11: Changing The Settings

    13. Note: For additional oscillation settings, see the Additional iDrive Options section or contact SonicAire Parts and Service at 1-336-712-2437 or at partsandservice@ sonicaire.com. The fan nozzle must be positioned to the right of the fan when viewing the iDrive for...
  • Page 12: Idrive Setting Options

    Connecting Link attachment position on each the Drive and Driven Discs. Important: Contact SonicAire for assistance if you are not certain of your selection or simply want to confirm your selection process. Warning: Improper attachment of the...
  • Page 13 SonicAire XT205 (380v) Owner’s Manual Hanging fans 1 1 - - Z Z G G Standard Oscillation 3 3 - - Y Y E E Maximum Oscillation Standing fans 3 3 - - Y Y K K Standard Oscillation 3 3 - -...
  • Page 14: Additional Idrive Options

    SonicAire XT205 (380v) Owner’s Manual Additional iDrive options Each of the following fan diagrams illustrates a range of oscillation settings for a particular Drive Disc number (1-6) Driven Disc axis combination. This combination determines how wide the vertical oscillation radius will be. The final iDrive...
  • Page 15 SonicAire XT205 (380v) Owner’s Manual Standing fans J J K K L L M M 3 Y_ 3 Z_ 70° 70° 56° 56° Coverage Coverage Coverage Coverage L L M M N N J J K K I I J J K K...
  • Page 16: Variable Frequency Drive

    In addition to the keypad programming below, to run the SonicAire fan through the on/off knob control it is CRITICAL to wire the 1 and 2 control terminals with a standard gauge wire.
  • Page 17 3-phase AC Input power out SonicAire fan to run with 50Hz, 380 source voltage. In addition to the terminal 1 and 2 connection mentioned above, use Figure 1.2 to correctly configure your VFD for power-in from source and power-out to fan.
  • Page 18 19 Hold square button for 2 seconds. The fan is now completely programmed to run with its basic settings. Now that the drive has been reprogrammed to SonicAire defaults, reconnect the 1 and 2 control terminals as designated in Figure 1.2.
  • Page 19: Wiring Diagrams

    SonicAire XT205 (380v) Owner’s Manual Wiring diagrams SonicAire fan wiring diagram XT205-380v Primary Motor Motor (hp) Overload Gearmotor (W) Protection and LOTO MSP (380v) 0.14 Disconnect Provided by Others Fan Enclosure Slip Ring BK BL GEAR MOTOR FAN MOTOR...
  • Page 20 Properly Sized Conductors Additional fans on same circuit Power Contacts Overload Heaters Motor Starter/ Local Protection Provided by Others Properly Sized Conductors Fan Motor Fan Motor Fan Motor Fan #1 Fan #2 Fan #3 Multiple SonicAire Fans on the same circuit...
  • Page 21: Troubleshooting

    If motor protection equipment does not need to be reset, contact SonicAire Tech Support. If the above solutions do not correct or address the problem, please contact SonicAire Parts & Service at 1.336.712.2437 or email partsandservice@sonicaire.com Please have the model and serial number available...
  • Page 22: Ec Declaration Of Conformity

    This declaration does not include any guarantee of property. The instructions of security of the enclosed product documentation have to be observed. The declaration becomes void in cases of modification of the product which have not been authorized by SonicAire. Local contact for regulatory topics only: SonicAire, Inc.