LASER TECH TruPulse 360i User Manual
Hide thumbs Also See for TruPulse 360i:
Table of Contents

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TruPulse 360i and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for LASER TECH TruPulse 360i

  • Page 2 Centennial, CO 80112 USA Support, FAQ & Tech Documents: https://lasertech.com/software-solutions RMA Request: www.lasertech.com/customer-service TruPulse 360i Reference Information: Record information about your TruPulse 360i in the table below. You can find this value: Value Serial On the serial number sticker affixed to Number the TruPulse 360i or on packaging.
  • Page 3: Table Of Contents

    Section 1 - Introducing the LTI TruPulse 360i ....... . .
  • Page 4 Laser Technology, Inc. TruPulse 360i User’s Manual 1st Edition Table of Contents Page 2 Section 8: Bluetooth Communication ............
  • Page 5: Precautions

    • Calibrate the TruPulse 360i before use. When you first receive your TruPulse 360i, the Inclination Sensor and Compass Sensor has been calibrated in the factory. Refer to the pages listed below for the User Calibration for the sensors if: •...
  • Page 6: Section 1 - Introducing The Lti Trupulse 360I

    Measures slope distance, inclination & azimuth, and calculates horizontal distance, vertical distance, height, and missing line values. The TruPulse 360i offers higher levels of distance, inclination, and azimuth accuracy with Bluetooth wireless communication to any device. Take advantage of Laser Tech's Advanced Targeting Modes (Closest, Farthest, Continuous, and Filter) and TruTargeting technology to know exactly what accuracy level is being achieved.
  • Page 7: Understanding How The Trupulse 360I Works

    6 to 10 seconds depending on Targeting mode. Once the target is acquired or the laser has timed out, you can release the FIRE button. The TruPulse 360i has a broad spectrum of sensitivity and can work with both reflective and non-reflective targets.
  • Page 8: Truvectorâ„¢ Technology

    The TruPulse 360i produces accurate and repeatable azimuth and inclination results. This is accomplished by combining a 3-axis magnetic sensor with a 3-axis tilt sensor - so the TruPulse 360i always knows its position in 3D space, and the direction of the Earth's magnetic field. TruVector technology allows you the ultimate freedom to “measure any angle.”...
  • Page 9: Section 2 - Getting Started

    Laser Tech's Professional Measurement FAQs technical documents website (https://lasertech.com/professional-measurement-faqs/). Manually Power Off The TruPulse 360i can be powered off by pressing and holding both Navigation buttons (“B” in Figure 1 above) at the same time for 3 seconds. Focus Adjust the Diopter Focus Ring (“G”...
  • Page 10: Measurement Display Layout

    Laser Technology, Inc. TruPulse 360i User’s Manual 1st Edition Section 2 - Getting Started Page 8 Measurement Display Layout Inclination Value Azimuth Value Measurement Icons Range Value Figure 2 Copyright© 2024, Laser Technology, Inc. All rights reserved.
  • Page 11: Section 3 - Basic Measurement

    Laser Technology, Inc. TruPulse 360i User’s Manual 1st Edition Section 3 - Basic Measurement Page 9 Section 3 - Basic Measurement Press FIRE button to power ON the TruPulse 360i. Select a target such as a tree or a building.
  • Page 12: Section 4 - Basic Operations

    Battery Lock Out Screen Button Navigation The TruPulse 360i has five buttons. With the TruPulse 360i in your right hand and looking through the eyepiece, the FIRE button and all other buttons are located on top of the instrument (Figure 5).
  • Page 13: Trupulse 360I Display

    Section 4 - Basic Operations Page 11 TruPulse 360i Display The TruPulse 360i is equipped with a Ultra Bright LED HUD. The TruPulse's internal software is organized into options. Each option represents a specific measurement or setup function and has a corresponding display indicator.
  • Page 14: Display Indicator Test

    Slope Distance Straight line distance between the TruPulse 360i and the target. Measurement Horizontal The level distance between the TruPulse 360i and the plane of the target. Distance Measurement Vertical The distance between the target and the perpendicular to the path Distance of the horizontal distance.
  • Page 15: Eyepiece

    Laser Technology, Inc. TruPulse 360i User’s Manual 1st Edition Section 4 - Basic Operations Page 13 Eyepiece The adjustable eyepiece is designed for comfort and to block extraneous light. • To extend the eyepiece, turn the eyepiece counter-clockwise while pulling up.
  • Page 16: Neck Strap

    Laser Technology, Inc. TruPulse 360i User’s Manual 1st Edition Section 4 - Basic Operations Page 14 Neck Strap To attach the neck strap: Disconnect the anchor end of the strap using the buckle. Figure 10 Feed loop around metal bar.
  • Page 17: Section 5 - Measurement Modes

    Section 5 - Measurement Modes When you power ON the TruPulse 360i, the last used Measurement Mode will be active. Press the Navigation buttons to display other Measurement Modes. Figure 12 shows the five different types of measurements that the TruPulse 360i can take.
  • Page 18: Inclination Percent Slope

    Laser Technology, Inc. TruPulse 360i User’s Manual 1st Edition Section 5 - Measurement Modes Page 16 Distance, Inclination, and Azimuth Measurements Workflow Figure 13 Inclination Percent Slope The Inclination units can be changed from Degrees to Percent. Refer to Section 7...
  • Page 19: Height Routine (3-Point Routine)

    Height Measurements involve a simple routine that prompts you to take 3 shots to the target: Horizontal Distance, Inclination Angle_1 and Inclination Angle_2. The TruPulse 360i uses these results to calculate the height of the target. In the routine, the next measurement required will auto sequence once the first measurement is acquired.
  • Page 20 Laser Technology, Inc. TruPulse 360i User’s Manual 1st Edition Section 5 - Measurement Modes Page 18 Height Routine (3-Point Routine) Workflow Figure 16 Copyright© 2024, Laser Technology, Inc. All rights reserved.
  • Page 21: Height Routine (2-Pt Routine)

    Laser Technology, Inc. TruPulse 360i User’s Manual 1st Edition Section 5 - Measurement Modes Page 19 Height Routine (2-pt Routine) This measurement routine is ideal for leaning objects and requires a clear line of sight for both shots. Press Navigation buttons until the Vertical Distance (VD) indicator is displayed.
  • Page 22: Missing Line Routine

    Laser Technology, Inc. TruPulse 360i User’s Manual 1st Edition Section 5 - Measurement Modes Page 20 Missing Line Routine The Missing Line Routine calculates distances and angles to describe the relationship between two points in three-dimensional space (connecting vector). This routine is ideal for span lengths, remote slope determinations, and changes in elevation from one location.
  • Page 23 Laser Technology, Inc. TruPulse 360i User’s Manual 1st Edition Section 5 - Measurement Modes Page 21 Tips • Improving the Accuracy of Handheld Results • During the Missing Line Routine, it is important that the TruPulse stay positioned above one particular point on the ground.
  • Page 24: Section 6 - System Setup Mode

    Laser Technology, Inc. TruPulse 360i User’s Manual 1st Edition Section 6 - System Setup Mode Page 22 Section 6 - System Setup Mode The System Setup Mode can be accessed from the Measurement Mode. Each option is described separately in the following sections: •...
  • Page 25: Bluetooth Options

    Page 23 Bluetooth Options The TruPulse 360i is equipped with Bluetooth® module that adds functionality to connect to Classic BT and Bluetooth Low Energy (BLE) devices. Bluetooth ® is a short-range wireless technology standard that is used for exchanging data between fixed and mobile devices over short distances. The TruPulse 360i will output messages to the connected device, refer to the “LTI TruPulse 2 Bluetooth Communications”...
  • Page 26 • Verify that the Bluetooth device is physically located within the wireless transmission range of the TruPulse 360i. Transmission range can vary depending upon (1) position relative to the TruPulse or (2) type of Bluetooth connection. Copyright© 2024, Laser Technology, Inc. All rights reserved.
  • Page 27: Aiming Reticle Options

    If you want to save the chosen Aiming Reticle option, power off the TruPulse 360i (Page 22). • Each time the TruPulse 360i is powered ON, it will return to the saved Aiming Reticle option. Copyright© 2024, Laser Technology, Inc. All rights reserved.
  • Page 28: Declination

    You only need to enter the location (US zip code) and date of interest. NOTE Do not set a Declination value in the TruPulse 360i if you use a GPS/GNSS and Software/App that applies a local Declination.
  • Page 29: Local Magnetic Attractions

    Laser Technology, Inc. TruPulse 360i User’s Manual 1st Edition Section 6 - System Setup Mode Page 27 Local Magnetic Attractions Local magnetic attractions are caused by objects of iron, steel, cobalt, nickel, and other ferro-magnetic materials. Electric utility lines may also affect compass readings. Direct current power utility lines will cause a fixed offset, and alternating currents will cause an unstable compass reading.
  • Page 30: Factory Reset

    Section 6 - System Setup Mode Page 28 Factory Reset It is possible to restore the TruPulse 360i factory default settings. Restoring the default settings affects some of the system setup options. Long press the Menu button, the bt option will be displayed.
  • Page 31: Code Firmware

    Laser Technology, Inc. TruPulse 360i User’s Manual 1st Edition Section 6 - System Setup Mode Page 29 Code Firmware The code firmware revision number provides Laser Tech Service Department information about your TruPulse 360i. To display the code firmware revision: Long press the Menu button, the bt option will be displayed.
  • Page 32: Section 7 - Settings Mode

    Laser Technology, Inc. TruPulse 360i User’s Manual 1st Edition Section 7 - Settings Mode Page 30 Section 7 - Settings Mode The Settings Mode can be accessed from the Measurement Mode. Each option is described separately in the following sections: •...
  • Page 33: Brightness Levels

    If you want to save the chosen Brightness Level option, power off the TruPulse 360i (Page 30). • Each time the TruPulse 360i is powered ON, it will return to the saved Brightness Level option. Copyright© 2024, Laser Technology, Inc. All rights reserved.
  • Page 34: Targeting Modes

    Page 32 Targeting Modes The TruPulse 360i has five Target Modes which allow you to select or eliminate targets and to take the most accurate measurements possible in various field conditions. The selected Target Mode remains active until you select a different Target Mode.
  • Page 35 If you want to save the chosen Targeting Mode option, power off the TruPulse 360i (Page 30). • Each time the TruPulse 360i is powered ON, it will return to the saved Targeting Mode option. Copyright© 2024, Laser Technology, Inc. All rights reserved.
  • Page 36: Range Gate

    Laser Technology, Inc. TruPulse 360i User’s Manual 1st Edition Section 7 - Settings Mode Page 34 Range Gate Using the Range Gate option it is possible to artificially extend the instrument's minimum range and restrict its maximum range. The range minimum is the Short Gate and the range maximum is the Long Gate. The specified ranges, which are always slope distance values, form the gate window.
  • Page 37 If you want to save the chosen Range Gate values, power off the TruPulse 360i (Page 30). • Each time the TruPulse 360i is powered ON, it will return to the saved Range Gate values. Copyright© 2024, Laser Technology, Inc. All rights reserved.
  • Page 38: Units Of Measurements (Uom)

    Section 7 - Settings Mode Page 36 Units of Measurements (UoM) The TruPulse 360i allows you to choose the units of measure. Distance: meters or feet. Inclination: Degrees or % Slope. To change the units of measurement option: Short press the Menu button.
  • Page 39: Calibration

    Calibration Tilt Sensor Calibration The tilt sensor is aligned during assembly. In the rare event that your TruPulse 360i suffers a severe drop shock, refer to the instructions below to re-align the tilt sensor. Short Press Menu button to enter Setting menu.
  • Page 40: Compass Calibration

    Laser Technology, Inc. TruPulse 360i User’s Manual 1st Edition Section 7 - Settings Mode Page 38 Compass Calibration To begin the routine, you should be holding the TruPulse and facing towards Magnetic North. Always perform outside and away from magnetic interference.
  • Page 41: Section 8: Bluetooth Communication

    The TruPulse 360i Bluetooth module has Bluetooth Low Energy (BLE) and Bluetooth Classic architecture The module is Bluetooth v4.0 - Dual Mode. A description of command structures are found in a separate document “TruPulse 360i User Interface Communication Protocols and Commands”.
  • Page 42: Section 9 - Care & Maintenance

    Transmit and Receive Lenses. Use the provided lens cloth to wipe the lenses. Failure to keep the lenses clean may damage them. • Storing If you won't be using the TruPulse 360i again soon, remove the batteries before storing the instrument. Copyright© 2024, Laser Technology, Inc. All rights reserved.
  • Page 43: Section 10 - Specifications

    Laser Technology, Inc. TruPulse 360i User’s Manual 1st Edition Section 10 - Specifications Page 41 Section 10 - Specifications All specifications are subject to change without notice. Please refer to LTI's website for current specifications. If you are not able to locate the information on the website or if you do not have internet access, please contact LTI via phone or fax.
  • Page 44: Section 11 - Lti Limited Warranty

    Laser Technology, Inc. TruPulse 360i User’s Manual 1st Edition Section 11 - LTI Limited Warranty Page 42 Section 11 - LTI Limited Warranty What is Covered? Laser Technology, Inc. (LTI) warrants this product to be in good working order. Should the product fail to be in good working order at any time during the warranty period, LTI will, at its option, repair or replace this product at no additional charge.
  • Page 45: Section 12 - Main Display Lcd Characters

    Laser Technology, Inc. TruPulse 360i User’s Manual 1st Edition Section 12 - Main Display LCD Characters Page 43 Section 12 - Main Display LCD Characters The Main Display is used to convey messages and measurement results. Upper Left Display Characters...
  • Page 46 Laser Technology, Inc. TruPulse 360i User’s Manual 1st Edition Section 12 - Main Display LCD Characters Page 44 Lower Main Display Display Translation Display Alpha Display Alpha Height Routine Target Modes Bluetooth Off Shot Height Routine Bluetooth Gate Mode Angle 1...

Table of Contents