LASER TECH TruPulse 200i User Manual
Hide thumbs Also See for TruPulse 200i:

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TruPulse 200i and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for LASER TECH TruPulse 200i

  • Page 2 Centennial, CO 80112 USA Support, FAQ & Tech Documents: https://lasertech.com/software-solutions RMA Request: www.lasertech.com/customer-service TruPulse 200i Reference Information: Record information about your TruPulse 200i in the table below. You can find this value: Value Serial On the serial number sticker affixed to Number the TruPulse 200i or on packaging.
  • Page 3: Table Of Contents

    Section 1 - Introducing the LTI TruPulse 200i ....... . .
  • Page 4: Precautions

    Laser Technology, Inc. TruPulse 200i User’s Manual 1st Edition Precautions Page 2 Precautions • Avoid staring directly at the laser beam for prolonged periods. CLASS 1 LASER PRODUCT: Product complies with IEC60825-1 Ed. 3:2014-5 and  21CFR1040.10/11 per Notice 50:2007.
  • Page 5: Section 1 - Introducing The Lti Trupulse 200I

    Measures slope distance and inclination and calculate horizontal distance, vertical distance, height and 2D missing line values. The TruPulse 200i offers a higher level of distance and inclination accuracy along with increased scope magnification and Bluetooth® wireless communication to any device. Take advantage of Laser Tech's Advanced Targeting Modes (Closest, Farthest, Continuous, and Filter) and TruTargeting technology so you know exactly what accuracy level is being achieved.
  • Page 6: Understanding How The Trupulse 200I Works

    6 to10 seconds depending on Targeting mode. Once the target is acquired or the laser has timed out, you can release the FIRE button. The TruPulse 200i has a broad spectrum of sensitivity and can work with both reflective and non-reflective targets.
  • Page 7: Section 2 - Getting Started

    Laser Tech's Professional Measurement FAQs technical documents website (https://lasertech.com/professional-measurement-faqs/). Manually Power Off The TruPulse 200i can be powered off by pressing and holding both Navigation buttons (“B” in Figure 1 above) at the same time for 3 seconds Focus Adjust the Diopter Focus Ring until the image is sharp (“G”...
  • Page 8: Measurement Display Layout

    Laser Technology, Inc. TruPulse 200i User’s Manual 1st Edition Section 2 - Getting Started Page 6 Measurement Display Layout Inclination Value Range Value Measurement Icons Figure 2 Copyright© 2024, Laser Technology, Inc. All rights reserved.
  • Page 9: Section 3 - Basic Measurement

    Laser Technology, Inc. TruPulse 200i User’s Manual 1st Edition Section 3 - Basic Measurement Page 7 Section 3 - Basic Measurement Press FIRE button to power ON the TruPulse 200i. Select a target such as a tree or a building.
  • Page 10: Section 4 - Basic Operations

    Battery Lock Out Screen Button Navigation The TruPulse 200i has five buttons. With the TruPulse 200i in your right hand and looking through the eyepiece, the FIRE button and all other buttons are located on top of the instrument (Figure 5).
  • Page 11: Trupulse 200I Display

    Section 4 - Basic Operations Page 9 TruPulse 200i Display The TruPulse 200i is equipped with a Ultra Bright LED HUD. The TruPulse's internal software is organized into options. Each option represents a specific measurement or setup function and has a corresponding display indicator.
  • Page 12: Display Indicator Test

    Slope Distance Straight line distance between the TruPulse 200i and the target. Measurement Horizontal The level distance between the TruPulse 200i and the plane of the target. Distance Measurement Vertical The distance between the target and the perpendicular to the path Distance of the horizontal distance.
  • Page 13: Eyepiece

    Laser Technology, Inc. TruPulse 200i User’s Manual 1st Edition Section 4 - Basic Operations Page 11 Eyepiece The adjustable eyepiece is designed for comfort and to block extraneous light. • To extend the eyepiece, turn the eyepiece counter-clockwise while pulling up.
  • Page 14: Neck Strap

    Laser Technology, Inc. TruPulse 200i User’s Manual 1st Edition Section 4 - Basic Operations Page 12 Neck Strap To attach the neck strap: Disconnect the anchor end of the strap using the buckle. Figure 10 Feed loop around metal bar.
  • Page 15: Section 5 - Measurement Modes

    Section 5 - Measurement Modes When you power ON the TruPulse 200i, the last used Measurement Mode will be active. Press the Navigation buttons to display other Measurement Modes. Figure 12 shows the four different types of measurements that the TruPulse 200i can take.
  • Page 16: Inclination Percent Slope

    Laser Technology, Inc. TruPulse 200i User’s Manual 1st Edition Section 5 - Measurement Modes Page 14 Distance and Inclination Measurements Workflow Figure 13 Inclination Percent Slope The Inclination units can be changed from Degrees to Percent. Refer to Section 7...
  • Page 17: Height Routine (3-Point Routine)

    Height Measurements involve a simple routine that prompts you to take 3 shots to the target: Horizontal Distance, Inclination Angle_1 and Inclination Angle_2. The TruPulse 200i uses these results to calculate the height of the target. In the routine, the next measurement required will auto sequence once the first measurement is acquired.
  • Page 18 Laser Technology, Inc. TruPulse 200i User’s Manual 1st Edition Section 5 - Measurement Modes Page 16 Height Routine (3-Point Routine) Workflow Figure 16 Copyright© 2024, Laser Technology, Inc. All rights reserved.
  • Page 19: Height Routine (2-Pt Routine)

    Laser Technology, Inc. TruPulse 200i User’s Manual 1st Edition Section 5 - Measurement Modes Page 17 Height Routine (2-pt Routine) This measurement routine is ideal for leaning objects and requires a clear line of sight for both shots. Press Navigation buttons until the Vertical Distance (VD) indicator is displayed.
  • Page 20: 2D Missing Line Routine

    The simple routine prompts you to take two shots to targets: “Shot 1" and “Shot 2". The TruPulse 200i uses the results to calculate values between the two points: slope distance, inclination, horizontal distance, and vertical distance from Shot 1 to Shot 2.
  • Page 21 Laser Technology, Inc. TruPulse 200i User’s Manual 1st Edition Section 5 - Measurement Modes Page 19 2D Missing Line Routine Workflow Figure 18 Copyright© 2024, Laser Technology, Inc. All rights reserved.
  • Page 22: Section 6 - System Setup Mode

    Laser Technology, Inc. TruPulse 200i User’s Manual 1st Edition Section 6 - System Setup Mode Page 20 Section 6 - System Setup Mode The System Setup Mode can be accessed from the Measurement Mode. Each option is described separately in the following sections: •...
  • Page 23: Bluetooth Options

    (Page 20). • Each time the TruPulse 200i is powered ON, it will return to the same Bluetooth setting that was last used. • Bluetooth v4.0 - Dual Mode (Classic Bluetooth and BLE) Refer to the instructions below when connecting your TruPulse 200i to another Bluetooth device.
  • Page 24 • Verify that the Bluetooth device is physically located within the wireless transmission range of the TruPulse 200i. Transmission range can vary depending upon (1) position relative to the TruPulse or (2) type of Bluetooth connection. Copyright© 2024, Laser Technology, Inc. All rights reserved.
  • Page 25: Pulse Options

    Page 23 Pulse Options The TruPulse 200i has a Pulse Motor to help indicate the target has been acquired. This feature provides short vibrating pulses/bursts to give a tactile confirmation and to reinforce that the laser has locked on the target.
  • Page 26: Aiming Reticle Options

    If you want to save the chosen Aiming Reticle option, power off the TruPulse 200i (Page 20). • Each time the TruPulse 200i is powered ON, it will return to the saved Aiming Reticle option. Copyright© 2024, Laser Technology, Inc. All rights reserved.
  • Page 27: Factory Reset

    Section 6 - System Setup Mode Page 25 Factory Reset It is possible to restore the TruPulse 200i factory default settings. Restoring the default settings affects some of the system setup options. Long press the Menu button, the bt option will be displayed.
  • Page 28: Code Firmware

    Laser Technology, Inc. TruPulse 200i User’s Manual 1st Edition Section 6 - System Setup Mode Page 26 Code Firmware The code firmware revision number provides Laser Tech Service Department information about your TruPulse 200i. To display the code firmware revision: Long press the Menu button, the bt option will be displayed.
  • Page 29: Section 7 - Settings Mode

    Laser Technology, Inc. TruPulse 200i User’s Manual 1st Edition Section 7 - Settings Mode Page 27 Section 7 - Settings Mode The Settings Mode can be accessed from the Measurement Mode. Each option is described separately in the following sections: •...
  • Page 30: Brightness Levels

    If you want to save the chosen Brightness Level option, power off the TruPulse 200i (Page 27). • Each time the TruPulse 200i is powered ON, it will return to the same brightness setting that was last used. Copyright© 2024, Laser Technology, Inc. All rights reserved.
  • Page 31: Targeting Modes

    Page 29 Targeting Modes The TruPulse 200i has five Target Modes which allow you to select or eliminate targets and to take the most accurate measurements possible in various field conditions. The selected Target Mode remains active until you select a different Target Mode.
  • Page 32 If you want to save the chosen Targeting Mode option, power off the TruPulse 200i (Page 27). • Each time the TruPulse 200i is powered ON, it will return to the saved Targeting Mode option. Copyright© 2024, Laser Technology, Inc. All rights reserved.
  • Page 33: Range Gate

    Laser Technology, Inc. TruPulse 200i User’s Manual 1st Edition Section 7 - Settings Mode Page 31 Range Gate Using the Range Gate option it is possible to artificially extend the instrument's minimum range and restrict its maximum range. The range minimum is the Short Gate and the range maximum is the Long Gate. The specified ranges, which are always slope distance values, form the gate window.
  • Page 34 If you want to save the chosen Range Gate values, power off the TruPulse 200i (Page 27). • Each time the TruPulse 200i is powered ON, it will return to the saved Range Gate values. Copyright© 2024, Laser Technology, Inc. All rights reserved.
  • Page 35: Units Of Measurements (Uom)

    Section 7 - Settings Mode Page 33 Units of Measurements (UoM) The TruPulse 200i allows you to choose the units of measure. Distance: meters or feet. Inclination: Degrees or % Slope. To change the units of measurement option: Short press the Menu button.
  • Page 36: Section 8: Bluetooth Communication

    The TruPulse 200i Bluetooth module has Bluetooth Low Energy (BLE) and Bluetooth Classic architecture The module is Bluetooth v4.0 - Dual Mode. A description of command structures are found in a separate document “TruPulse 200i User Interface Communication Protocols and Commands”. w Both Bluetooth Classic and BLE modes implement an ASCII command-response communication scheme described in the section Data Format.
  • Page 37: Section 9 - Care & Maintenance

    Transmit and Receive Lenses. Use the provided lens cloth to wipe the lenses. Failure to keep the lenses clean may damage them. • Storing If you won't be using the TruPulse 200i again soon, remove the batteries before storing the instrument. Copyright© 2024, Laser Technology, Inc. All rights reserved.
  • Page 38: Section 10 - Specifications

    Laser Technology, Inc. TruPulse 200i User’s Manual 1st Edition Section 10 - Specifications Page 36 Section 10 - Specifications All specifications are subject to change without notice. Please refer to LTI's website for current specifications. If you are not able to locate the information on the website or if you do not have internet access, please contact LTI via phone or fax.
  • Page 39: Section 11 - Lti Limited Warranty

    Laser Technology, Inc. TruPulse 200i User’s Manual 1st Edition Section 11 - LTI Limited Warranty Page 37 Section 11 - LTI Limited Warranty What is Covered? Laser Technology, Inc. (LTI) warrants this product to be in good working order. Should the product fail to be in good working order at any time during the warranty period, LTI will, at its option, repair or replace this product at no additional charge.
  • Page 40: Section 12 - Main Display Lcd Characters

    Laser Technology, Inc. TruPulse 200i User’s Manual 1st Edition Section 12 - Main Display LCD Characters Page 38 Section 12 - Main Display LCD Characters The Main Display is used to convey messages and measurement results. Upper Left Display Characters...
  • Page 41 Laser Technology, Inc. TruPulse 200i User’s Manual 1st Edition Section 12 - Main Display LCD Characters Page 39 Lower Main Display Display Translation Display Alpha Display Alpha Height Routine Brightness Bluetooth Off Shot Level 4 Height Routine Brightness Bluetooth Angle 1...

Table of Contents