TruPulse® 360i Compass Calibration
TruVector Compass Technology®: Combines 3D magnetic sensor with the 3D angle sensor to
know its precise orientation in 3D space.
To begin the routine, you should be holding the TruPulse and facing towards Magnetic North. Always perform
outside and away from magnetic interference.
The compass is susceptible to magnetic interference and should be kept away from all ferro-magnetic
materials and strong magnetic fields when performing the compass calibration. Do not perform the calibration
inside a building, or in or near vehicles. The user calibration for the compass merely compensates for the
magnetic changes of the unit itself.
Refer to Laser Tech's TruPulse 360i Magnetic Interference Guidelines pdf on the website.
Procedure:
Short Press Menu button to enter Settings menu.
1.
Press Menu button to scroll to the User Calibration option.
2.
Press the Select Button to enter the User Calibration options.
3.
Press Navigation Buttons to "Yes 360 Calbrt" display. Press the Select button.
4.
At each step, wait approximately 1 second before pressing the FIRE button.
5.
Then wait another second before moving to the next position. It is important that the
a.
unit is held steady when the button is pressed.
Calibration Sequence:
Face North (+/- 10 degrees), hold in position 1, press FIRE button.
1.
Hold in position 2, press FIRE button.
2.
Hold in position 3, press FIRE button.
3.
Hold in position 4, press FIRE button.
4.
Hold in position 5, press FIRE button.
5.
Hold in position 6, press FIRE button.
6.
Hold in position 7, press FIRE button.
7.
Hold in position 8, press FIRE button.
8.
If Fail Message appears, repeat steps 1 through 8.
9.
If Pass Message appears, press FIRE button return to the measurement screen.
10.
Measurably Superior® | ISO 9001:2008 Certified | Awarded 63 Patents Worldwide | Celebrating Over
6912 South Quentin Street, Suite A | Centennial, Colorado 80112 USA | 1.303.649.1000 [PHONE] | 1.303.649.9710 [FAX]
30 Years
of Innovation
LASERTECH.COM
Need help?
Do you have a question about the TruPulse 360i and is the answer not in the manual?
Questions and answers