AJCQ09DCD
Built-in RAC Installation
GE
ENERGY STAR
®
Dimensions (in inches)
Installation Information: A finished opening of 26-1/8" x
15-3/4" clear of intrusions is required. Keep clearance of
4" from side walls. Brick veneer or frame walls should have
wood studding surrounding case to provide firm anchoring
with screws. Case can be fastened directly to brick or block
walls with screws sunk in lead expansion shields.
Note: Units should be caulked on all four sides of case
to the building exterior to assure building integrity.
Two Wall Cases for Tenant Option Installation
When the air conditioner is offered as a tenant option, these
wall cases provide protection against outside elements.
RAB47 – includes wall case, exterior grille
and steel closure panels.
RAB48 – includes wall case, exterior grille,
steel closure panel and two layers of insulation.
Standard Wall Case RAB46
Solid-sided wall case fabricated of galvanized steel with
baked enamel finish. Welded areas are coated with
a sealing compound to help resist rust and corrosion.
Polymer gasket surrounds opening to assure tight weather
seal. Aluminum grille (RAG13) is included. Panels on interior
and between case and grille provide weather protection prior
to installation of chassis. Provide firm anchoring with screws.
Case can be fastened directly to brick or block walls with
screws sunk in lead expansion shields.
For answers to your Monogram,
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
800.626.2000.
230/208 Volt Built-in Room Air Conditioner
®
GE Profile
or
®
service,
®
Make frame if desired or caulk
Make frame if desired or caulk
between case and siding
between case and siding
26-1/8
26-1/8
Frame Construction
Frame Construction
15-3/4
26-1/8
26-1/8
Brick Block and Brick
Brick Block and Brick
Frame Construction
Frame Construction
Lintel
Lintel
OUTSIDE
OUTSIDE
16-7/8
16-7/8
Brick Block and Brick
Frame Construction
Lintel
OUTSIDE
15-3/4
15-3/4
Caulking
Drip Rail
Flexible Mounting Position
Lintel
Lintel
15-3/4
Fill open cells
Fill open cells
with mortar
with mortar
or insulation
or insulation
Plaster Line
Plaster Line
Trim Molding
Trim Molding
(if desired)
(if desired)
Specification Created 9/09
INSIDE
INSIDE
Fill open cells
with mortar
or insulation
Plaster Line
Trim Molding
(if desired)
INSIDE
16-7/8
Total volume and shelf
Listed by
area are calculated by
Underwriters
the Association of Home
Laboratories
Appliance Manufacturers'
standards.
390255