Advertisement

Quick Links

GEAppliances.com
Safety Instructions
. . . . . . . . . 2, 3
Operating Instructions
Care and Cleaning
Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Front Grille . . . . . . . . . . . . . . . . . . . . . . . .7,9
Grille and Case . . . . . . . . . . . . . . . . . . . 7,9
Outdoor Coils . . . . . . . . . . . . . . . . . . . . 7,9
Before You Begin . . . . . . . . . . . . . . .12-13
Installing a J-Model in
an Existing Wall Case . . . . . . . . . . . . . 14
Through-the-Wall
Installation . . . . . . . . . . . . . . . . . . . . . . . 15
Normal Operating Sounds . . . . . . . 16
Consumer Support
Consumer Support . . . . . . Back Cover
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . 19
*E
S
labeled product
®
NERGY
TAR
As an E
S
partner, GE has
®
NERGY
TAR
determined that this product meets the
E
S
guidelines for energy efficiency.
®
NERGY
TAR
Write the model and serial
numbers here:
Model # _________________________
Serial #
____________________________
Find these numbers on a label on the front of
the base pan behind the front grille.
. . . . . 4-6
Español
. . . . . . . 16
For a Spanish version of this manual, visit
our Website at GEAppliances.com.
Para consultar una version en español de
este manual de instrucciones, visite nuestro
sitio de internet GEAppliances.com.
Française
For a French version of this manual, visit
our Website at GEAppliances.com.
Pour une version française de ce manuel
d'utilisation, veuillez visiter notre site web
à l'adresse GEAppliances.com.
Owner's Manual and
Installation Instructions
Cool Only:
AJCM 08, 10
AJCM 10, 12
AJCQ 06
AJCQ 08, 10, 12
AJCQ 09, 10, 12
Heat/Cool:
AJEM 12
AJEQ 06
AJEQ 08
AJEQ 09, 10, 12
49-7710 5-13 GE
ACF*
DCF*
LCF*
ACF*
DCF*
DCE/F
LCE/F
ACE/F
DCE/F

Advertisement

Table of Contents
loading

Summary of Contents for GE AJCM 08 ACF

  • Page 1: Table Of Contents

    For a French version of this manual, visit our Website at GEAppliances.com. Pour une version française de ce manuel d’utilisation, veuillez visiter notre site web à l’adresse GEAppliances.com. As an E partner, GE has ® NERGY determined that this product meets the guidelines for energy efficiency. ®...
  • Page 2 IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. SAFETY PRECAUTIONS use a cord that shows cracks or abrasion WARNING! Risk of electric shock. Can damage along its length or at either the cause injury or death. For your safety, plug or connector end. the information in this manual must be followed to Turn OFF and unplug your air conditioner minimize the risk of fire, electric shock or personal...
  • Page 3 GEAppliances.com WARNING! USE OF EXTENSION CORDS RISK OF FIRE. Could cause serious injury or death. DO NOT use an extension cord with this Built-in Air Conditioner. DO NOT use surge protectors or multi-outlet adaptors with this Built-in Air Conditioner. USE OF ADAPTER PLUGS WARNING! When disconnecting the power cord from Risk of electric shock.
  • Page 4 Appearance may vary. Power Cool Cool Mode Mode Temp High Delay Hrs Temp Delay Power Reset On/Off Filter Remote Control Air Conditioner Controls Lights beside the touch pads on the air conditioner control panel indicate the selected settings. Controls Power On/Off To cancel the Delay Timer, press the On pad until “CL”...
  • Page 5 GEAppliances.com Cool Mode Remote Control Set the thermostat at a higher number and the indoor air will become warmer. 1. Press Cool pad. NOTE: If the air conditioner is off and is then turned on 2. Press Low, Med or High pads to set desired fan speed. while set to Cool, it will take approximately 3 minutes for the compressor to start and cooling to begin.
  • Page 6 Appearance may vary. Air Conditioner Controls Remote Control Lights beside the touch pads on the air conditioner control panel indicate the selected settings. Controls ON/OFF TIMER When the air conditioner is off, it Turns air conditioner on and off. can be set to automatically turn on in Display half an hour to 24 hours at its previous Displays the temperature setting.
  • Page 7 GEAppliances.com COOL MODE Remote Control Set the thermostat at a higher number and the indoor air will become warmer. 1. Press COOL pad. NOTE: If the air conditioner is off and is then turned on while set 2. Press LOW or HIGH pads to set desired fan speed. to COOL, it will take approximately 3 minutes for the compressor to start and cooling to begin.
  • Page 8 About the controls on the air conditioner Vent Control The vent control is located behind the front grille on the right The unit leaves the factory set at the CLOSE position. side of the air discharge area. When CLOSED, only the air Locating hole Locating hole inside the room will be circulated and conditioned.
  • Page 9 GEAppliances.com Fan Cycle/Continuous - Cool Fan Cycle/Continuous - Cool When this switch is enabled (UP), it allows the indoor fan to cycle on/off with the compressor. When this switch is disabled (DOWN), it allows the indoor fan to run continuously. The default setting is DOWN (continuous). Fan Cycle/Continuous - Heat Fan Cycle/Continuous - Heat When this switch is enabled (UP), it allows the indoor...
  • Page 10: Front Grille

    If they are clogged with dirt or soot they may be professionally steam cleaned, a service available through your GE service outlet. Front Grille The front grille can be removed for more thorough 3. Pull the grille out from the bottom and lift up cleaning and to locate the model and serial numbers from the tabs on the top of the case.
  • Page 11 Replacement filters are available from your salesperson, GE dealer, GE Service and Parts Center or authorized Customer Care servicers. ®...
  • Page 12: Installation Instructions

    GE strongly recommends the removal of the old wall case use a GE Wall Case, you run the risk of poor performance or product failure. This is not covered under the terms of the GE warranty.
  • Page 13 Level Pencil Adjustable Wrench USE GE RAB46A ,46, Use these kits for all GE Standard wall case for “J” model chassis. RAG13 stamped 47A, 47, 48A, models and other brands aluminum exterior grille included. Remove the existing case 48B & 48 not listed and replace.
  • Page 14 Installation Instructions Read these instructions completely and carefully. INTO CASE Make sure that the tubing on the unit does not touch the wall case and that the case installation is secure. Remove the two screws behind the filter then remove the front grille.
  • Page 15 Installation Instructions Read these instructions completely and carefully. Make certain a wall receptacle is available close to the hole location or make arrangements to install Mortar between the case and the brick wall around a receptacle. the case may be undercut at about 45° for improved caulking.
  • Page 16: Troubleshooting Tips

    Before you call for service… Troubleshooting Tips: Save time and money! Review the chart below first and you may not need to call for service. Problem Possible Causes What To Do Air conditioner The air conditioner does not start is unplugged. into the outlet.
  • Page 17 Notes.
  • Page 18 Notes.
  • Page 19 This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA and Canada. If the product is located in an area where service by a GE Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service location for service.
  • Page 20: Consumer Support

    Contact Us GEAppliances.com If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations...

Table of Contents