Connect the cable to the outdoor unit
1. Remove the electrical control
board cover from the outdoor unit
by loosening the screw.
2. Connect the connective cables to
the terminals as identified with
their respective matched numbers
on the terminal block of indoor
and outdoor units. The connective
cable to power supply shall be
approved polychloroprene
sheathed flexible cord, type
designation 14AWG or heavier
cord.
3. Secure the cable onto the control
board with the cord clamp.
4. To prevent the ingress of water,
form a loop of the connective
cable as illustrated in the
installation diagram of indoor and
outdoor units.
5. Insulate unused cords (conductors)
with PVC-tape. Process them so
they could not touch any electrical
or metal parts.
< 12000 btu's CABLE (Cooling model)
Electrical work
21
Code wire
< 12000 btu's CABLE
(Heating and cooling model)
or
"Cable D"
Code wire
1.57"
0.39"
> 12000 btu's CABLE
(Heating and cooling model)
"Cable F"
Code wire
1.57"
0.39"
Cover
Screw
"Cable E"
Code wire
1.57"
0.39"