Warnings and precautions for safety Please observe the following safety precautions in order to use safely and correctly the refrigerator and to prevent accident and danger during repair. 1. Be care of an electric shock. Disconnect power cord from wall outlet and wait for more than three minutes before replacing PCB parts.
Circuit diagram Compulsory defrost Connecting power within 1 minute, refrigerater or freezer door open situation, press Fridge and super cool 3 seconds, enter the compulsory defrosting process: ——--After entering the compulsory defrosting, we can run the defrosting same as the normal automatic defrosting process.
Compulsory defrost Connecting power within 1 minute, refrigerater or freezer door open situation, press Fridge and Quick frozen 3 seconds, enter the compulsory defrosting process: ——--After entering the compulsory defrosting, we can run the defrosting same as the normal automatic defrosting process.
Page 9
If the test result is not in this range then it means the inner coil has some problem and the compressor can not work properly. Compressor Protector test —— Use a multi-meter to test the resistance between the two end as the pic show : If there show 000 or almost 0 then it is OK.
Checking the heater If defrost system failure,check the heater and the temperature fuse as well as wires. Measuring temperature fuse and heater resistance about 304Ω then it is OK.( gray and Blue) Checking the defrost fuse Fuse is a high temperature protector of defrost system, when defrosting, if it feel the temperature is more than 73℃, it will cut off the defrost heater, stopping defrost, so that it can protect the parts.
Picture 1 Picture 2 As picture 1,it is the defrost fuse. As picture 2 , using the multimeter measure two foots of fuse, if the value of resistance is 0000, it means normal. Measuring the sensor resistance Rr sensor White line Rv sensor Gray line...
Using a multimeter with the ohm switch to measure the resistor of sensor, normally at surrounding 25℃ the resistor should be about 2kohm and every with the temperature decreases 1℃ the corresponding resistor value would increase about 45ohm. If the measured value is not within the normal scope, the sensor is bad and needs to repair or change.
Remove the electron box cover and replace the main board. ◆The instruction of of replacing fan motor Remove the wind channel plate in freezer chamber. Remove the air duct Board Open air duct Board...
Unscrew the fan motor screws And take out fan motor ◆The instruction of replacing temperature sensor. Open air duct Board And take out sensor ◆The instruction of replacing evaporator temperature sensor and temperature fuse and heater The instruction of replacing evaporator temperature sensor and temperature fuse...
The instruction of replacing heater ◆The instruction of replacing PTC Starting relay and Overload protector. 1. The location of the PTC Starting relay and Overload protector. 2. Disconnect the connecting wire of the PTC Starting relay and Overload protector. ◆The instruction of replacing Door switch.
Using a screwdriver to pry the upper cover plate And take out switch ◆The instruction of replacing Display board. 1. The location of the display board . 2. Unplug the display board wires and remove the screws fixing . ◆The instruction of of replacing LED Light. 1.
◆ The solution for digital display code problem: 1. The Refrigerator chamber 1. Using a Multimeter with the ohm Tem. Sensor is open circuit or switch to measure the resistor of The digital display window short circuit. sensor or checking the connecting is show “E1”...
2.5 Does there open the door frequently? 2.6 Is the door completely closed? 2.7 Does the gasket destroyed or distort? 2.8 Does the gas leak? 3.1 Is there any heat source around the refrigerator? 3.2 Is there enough space around the refrigerator for rejection of heat? 3.3 Is the setting of the temperature appropriate? 3.4 Is there too much food or overheating food in it? The unit can not stop...
Page 24
Phenomenon of failure: tube, and then sealed it, vacuuming a. lower pressure of liquid cycle system it, finally recharge with Gas. b. high temperature of copper tube of Note: discharging gas, hand feels very hot. If you find oil on somewhere, it is C.
Page 25
Reason analysis Solutions: Phenomenon of failure: First find out the point of leaking on tube, and a, leaking fast then sealed it, vacuuming it, finally recharge b, leaking slowly with gas. 1) Leakage of gas c, no voice of liquid flowing Note:...
Reason Solutions 1)The setting temperature is not reasonable. Readjust the temperature setting. 2) the sensor is bad. Replace the sensor. 3)Seal of door is damaged. Replace the gasket 4)Too much food in the refrigerator Please put the food properly. 5)Wind door is broken. Replace wind door.