DIMENSIONS
Tank Capacity
in Gallons
5
10
20
30
40
50
65
80
100
119

RECOVERY CAPACITY

STANDARD
BTU/
KW INPUT
HOUR
3
10,239
6
20,478
9
30,717
12
40,956
15
51,195
18
61,434
24
81,912
30
102,390
36
122,868
45
153,585
54
184,302
60**
204,780
75**
255,975
90**
307,170
* Figured at 1KW (3413 Btu) = 4.1 Gallons at 100°F temperature rise.
To determine recovery rate per minute, divide recovery rate per hour by 60.
NSF ratings may be obtained by multiplying above figures by 0.98.
**Available on 50 gallon models or larger.
Maximum
KW Input
A
3
20 /12
6
26 1/4
18
27 1/4
24
35 3/4
36
45 3/4
90
54 3/4
90
50 1/2
90
49 1/4
90
58 1/4
90
63 1/4
RECOVERY RATE IN GALLONS PER HOUR *
Temperature Rise °F
30°
40°
50°
60°
41
31
24
20
82
62
49
41
123
92
74
62
164
123
98
82
205
154
123
102
246
184
148
123
328
246
197
164
410
308
246
205
492
369
295
246
615
461
369
307
738
554
443
359
819
615
492
410
1025
768
615
512
1229
922
738
615
All Dimensions in Inches
B
C
16 1/4
21 1/2
18 3/4
24
20 1/2
27
20 1/2
27
20 1/2
27
20 1/2
27
24 1/2
30 1/4
26 1/2
32 1/4
26 1/2
32 1/4
28
33 3/4
70°
80°
90°
100°
17
15
13
12
35
31
27
25
53
46
41
37
70
61
55
49
88
77
68
61
105
92
82
74
140
123
109
98
176
154
137
123
112
211
184
164
148
134
263
230
205
184
168
316
277
246
221
201
351
307
273
246
223
439
384
341
307
279
527
461
410
369
335
2
Approx. Ship
D
Wt.Lbs.
5 1/4
82
5 1/4
106
5 3/4
130
5 3/4
150
5 3/4
190
5 3/4
221
7
267
7
285
7
354
7 1/2
420
110°
120°
130° 140°
11
10
10
9
22
21
19
18
34
31
28
26
45
41
38
35
56
51
47
44
67
62
57
53
90
82
76
70
103
95
88
123
113
105
154
142
132
185
170
158
205
189
176
256
236
219
307
284
263