Calibration Setup—Densitometer
NOTE:
Make sure that your densitometer is calibrated before you try to
calibrate your printer with the densitometer values.
Densitometer—This setting allows you to specify what type of density
data (Status A or Status T) your densitometer provides. The Calibration
Utility calculates the table data using the density type that the export
module needs for the current calibration slot.
Test Print — Number of Squares
The Number of Squares menu in the Test Print box allows you to specify
the number of squares (15 or 38) in your test print.