Parts & Service Information ³/��" weep holes Technical support Understanding the Warning IMPORTANT: Even if you have the Pro Series™ PS-C30 Replacement Parts Diagram & List Lights and Alarms Combination Sump Pump System installed by someone Scan the QR code...
Important Safety BATTERY PREPARATION receptacle, have a licensed electrician replace the vicinity of the battery. it with a 3-prong receptacle according to • Use the Pro Series control unit for charging a Warnings & Instructions WARNING/POISON local codes and ordinances. LEAD-ACID battery only.
Introduction The Combination Sump Pump System includes: The Pro Series pair of pumps combination A HP primary pump with a caged system is designed to provide both primary dual float switch, and a blue piggyback and backup pumping capabilities. The primary controller that plugs into the wall outlet pump will operate as long as it is receiving AC power.
Installing the Pipe and sump pit is not clean, remove as much of the sump pit. Make sure it is level. remove the pin, push the pointed end of debris as possible. The pumps are attached to the pin into the float connector and pull it Pump 8.
Battery Instructions 2. Connecting the battery: Remove the RED wires to the POSITIVE (+) posts and using a surge protector.) You will have 10 bolts from the hardware bag. Remove the BLACK wires to the NEGATIVE (-) seconds before the “Power failure” alarm This system will accommodate the B12-100 the security tag from the battery cables.
Product Operation replace your main pump. When the problem is corrected, the battery should recharge. The dual float switch on the primary pump • If no other lights are on, this means the contains two large floating rings enclosed terminals may be corroded, and the battery within a protective cage.
instructions and safety information included and unplug the AC pump and the blue could prevent the system from charging piggyback controller. properly. with the charger. 2. Remove the cover of the battery box by 7. Replace the battery cables and bolts on WARNING pushing in the tabs on the front and back, the top of the battery.
properly. from the battery. Then call Glentronics 1. If the power is on in the rest of the house, technical support for instructions at 800- check the home circuit breaker or fuse box 6. Replace the battery cables and bolts on 991-0466.
Page 9
DANGER PUMP Risk of electrical shock or battery explosion, which can cause serious injury or death. FUSE Wear eye protection. Work in a well- ventilated area. DO NOT smoke or allow a spark or flame in the vicinity of the battery. Avoid dropping metal tools on the battery.
REPLACING THE PRIMARY PUMP 4. Remove the battery wires from the battery 9. While you have the pump apart, this would 13. Lower the pump back into the pit by the posts. Be sure they DO NOT touch each be a good time to replace the check valves. handle of the primary pump.
each. Connect either wire to the common 17. Plug the power cord from the backup • No required monthly or yearly fees or control unit into the outlet. You should terminal. To secure the wire into the terminal, subscriptions provide additional protection to the system insert the exposed wire into the hole on the by using a surge protector.
Series website at www.stopflooding.com. Send your unit to the following address if repairs are needed: Glentronics, Inc. Attn: Service 645 Heathrow Drive, Lincolnshire, IL 60069-4205 Replacement Parts List PS-C30 Description Part Controller for backup pump PHCC-1850-CONT Enhanced dual float switch with controller for AC pump DFC1.5...
Primary Pump Troubleshooting Guide Backup Pump Troubleshooting Guide DANGER DANGER Read safety warnings & instructions before attempting any repairs or maintenance. Read safety warnings & instructions before attempting any repairs or maintenance. Potential Cause BATTERY PROBLEM Solutions Potential Cause THE PUMP WILL NOT START OR RUN Solutions Pump is not plugged in .
Page 14
Limited Warranty By opening this package and using this GLENTRONICS, INC. product, you are agreeing to be bound by the terms of the GLENTRONICS, INC. limited warranty (“warranty”) as set out below. Do not use your product until you have read the terms of the warranty. If you do not agree to the terms of the warranty, do not use the product and return it within the return period stated on your purchase receipt from the retail store or authorized distributor where you purchased it for a refund.
Page 15
Additional Products to Help Protect Your Basement Maintenance Free Battery Clenit Pump and Pro Series CONNECT Sewage Pump Pit Cleaner WiFi2 Module B12-100 E7055 PS-WIFI2 FEATURES AND BENEFITS: Sends emails, texts or in-app notifications Compatible with: and status alerts to your phone, tablet or computer ...
Page 16
Water Alarms & Accessories Water Alarm 360° Sensor 360° Water Alarm Pro Series CONNECT High Water Accessory PWA2 PS-WS360 PWA-360 PS-WS FEATURES AND BENEFITS: FEATURES AND BENEFITS: FEATURES AND BENEFITS: Patented 360˚ sensing technology detects FEATURES AND BENEFITS: water when placed on any side, top or ...
Need help?
Do you have a question about the PS-C30 and is the answer not in the manual?
Questions and answers