1 About this manual 1.1 Validity This operating manual is for customers of Pfeiffer Vacuum. It describes the func- tioning of the designated product and provides the most important information for safe use of the unit. The description follows applicable EU guidelines. All informa- tion provided in this operating manual refer to the current state of the product's de- velopment.
• Installation, operating and maintenance regulations must be complied with. • Other accessories than those described in this manual must not be used without the agreement of Pfeiffer Vacuum. 2.3 Improper use Improper use will cause all claims for liability and warranties to be forfeited. Im-...
4 Product description 4.1 Product identification To correctly identify the product when communicating with Pfeiffer Vacuum, al- ways have the information from the rating plate available. Variants The dust separators are supplied in various sizes and different designs. They es- sentially differ in the quantity of the separable pollution as well as in the different filter materials.
The SAS are designed for volume flow rates in the range of 6 ... 630 m /h depend- ing on the type. The separable particle size for both possible filter inserts is: Parameter SAS 20 SAS 90 SAS 250 SAS 630 Separable particle size, paper 2 μm...
Installation 5 Installation 5.1 Assembling The direction of flow inside the SAS is from the outside of the filter housing to the inside. Fig. 2: Permissible installation positions Remove the protective caps from the connection flanges. Install the SAS in a vertical or horizontal position in accordance with the illustra- tion.
Changing the filter elements Filter cover O-ring Filter housing Profile seal: (SAS 20 and SAS 250 one each at the bottom of the fil- ter housing, SAS 90 one at the bottom and one in the filter cover) Filter element SAS 630 Some inserts (SAS 630) are fastened additionally with a separate wing nut or fas- tening nut 6 and washer, which must be removed.
Page 9
Maintenance Cleaning Take special care during the cleaning process, since the filter elements can be dam- aged during dismantling, cleaning or assembly. This can result in unfiltered parti- cles entering into the pump and cause further damage. Polyester filter element ...
Fill out the "Service Request" form and send it by fax or e-mail to your Pfeiffer Vacuum service address. Include the confirmation on the service request from Pfeiffer Vacuum with your shipment. Fill in the contamination declaration and enclose it in the shipment (required!).
Technical data 9 Technical data Parameter SAS 20 SAS 90 Degree of separation 99.9 % 99.9 % Flange (in) DN female thread G 1/2" Female thread G 1 1/4" NPT 1/2" cone Flange (out) DN female thread G 1/2" Female thread G 1 1/4"...
Page 12
Technical data Dimensions SAS 20 SAS 90 SAS 250 SAS 630 ø 95 mm ø 146 mm ø 222 mm ø 337 mm ø 88 mm ø 128 mm ø 195 mm ø 305 mm 10 mm 19 mm 12.5 mm 24 mm 90.5...
SAS 90 PK E57 006 -T SAS 250 PK E57 007 -T SAS 630 PK E57 008 -T Maintenance kit polyester SAS 20 PK E57 009 -T SAS 90 PK E57 010 -T SAS 250 PK E57 011 -T SAS 630...
Page 14
Leading. Dependable. Pfeiffer Vacuum stands for innovative and custom Customer Friendly vacuum solutions worldwide. For German engineering art, competent advice and reliable services. Ever since the invention of the turbopump, we´ve been setting standards in our industry. And this claim to leadership will continue to drive us in the future.